Mounting the Door/Window Contact
Make sure the contact works properly before installation.
Step 1:
Choose a suitable installation location
It can be installed on doors, windows or any other objects that can be opened or closed.
If it is applied to metal doors, please place a spacer under the transmitter and magnet.
Step 2:
Secure the contact with the supplied sticker
Make sure the gap marks on the side of transmitter and magnet are closed to each other
and within the range of 1cm. As long as the space between transmitter and magnet is
over 2cm; The status indicator on the transmitter will blink once.
Mounting the PIR Motion Detector
lmportant:
Avoid installing the motion detector directly towards windows and near heat
sources, such as heat extraction units, air-condition, micro-wave oven, refrigerator etc;
Avoid placing two motion detectors in the opposite of each other; Don
’t place them in
each other
’s detection range.
Step 1:
The ideal
mounting height of the motion detector is 2-2.2 meters from the foor. It is suggested to
mount it at the corner of the wall by using the supplied 3M sticker.
Step 2:
Press the test button twice and walk from left to right in the room. The status
ndicator will blink once when motion is detected.
Note:
This PIR motion detector can also be mounted at special location by using the supplied
bracket and screw kits.