Input Impedance: 10M
.
Maximum Input: 1000V dc or 700V ac rms.
AC Voltage
(Auto-ranging)
Range
Resoluti
on
Accuracy
4.000V
1mV
+1.2% of rdg + 3 dgts
40.00V
10mV
+1.5% of rdg + 3 dgts
400.0V
100mV
700V
1V
+2.0% of rdg + 4 dgts
Input Impedance: 10M
.
Frequency Range:50 to 400Hz
Maximum Input: 1000V dc or 700V ac rms.
DC Current
(Auto-ranging for uA, mA ,A)
Range
Resolution
Accuracy
400.0uA
0.1uA
+1.0% of rdg + 3 dgts
4000uA
1uA
+1.5% of rdg + 3 dgts
40.00mA
10uA
400.0mA
100uA
4A
1mA
+2.5% of rdg + 5 dgts
20A
10mA
Overload Protection: 0.5A / 250V and 20A / 250V
Fuse.
Maximum Input: 400mA dc or 400mA ac rms on uA /
mA ranges, 20A dc or ac rms on 4A, 20A range.
AC Current
(Auto-ranging for uA , mA, A)
Range
Resolution
Accuracy
400.0uA
0.1uA
+1.5% of rdg + 5 dgts
4000uA
1uA
+1.8% of rdg + 5 dgts
40.00mA
10uA
400.0mA
100uA
4A
1mA
+3.0% of rdg + 7 dgts
20A
10mA
Overload Protection: 0.5A / 250V and 20A / 250V
Fuse.
Frequency Range: 50 to 400 Hz
Maximum Input: 400mA dc or 400mA ac rms on uA /
mA ranges, 20A dc or ac rms on 4A, 20A range.
Resistance
(Auto-ranging)
Range
Resolution
Accuracy
400.0
0.1
+1.2% of rdg + 4 dgts
4.000k
1
+1.0% of rdg + 2 dgts
40.00k
10
+1.2% of rdg + 2 dgts
400.0k
100
4.000M
1k
40.00M
10k
+2.0% of rdg + 3 dgts
Input Protection: 250V dc or 250V ac rms.
Capacitance
(Auto-ranging)
Range
Resolution
Accuracy
40.00nF
10pF
+5.0% of rdg + 7 dgts
400.0nF
0.1nF
4.000uF
1nF
+3.0% of rdg + 5 dgts
+3.0% of rdg + 5 dgts
40.00uF
10nF
100.0uF
0.1uF
+5.0% of rdg + 5 dgts
Input Protection: 250V dc or 250V ac rms.
Frequency
(Auto-ranging)
Range
Resolution
Accuracy
9.999Hz
0.001Hz
+1.5% of rdg + 5 dgts
99.99Hz
0.01Hz
999.9Hz
0.1Hz
+1.2% of rdg + 3 dgts
9.999kHz
1Hz
99.99kHz
10Hz
999.9kHz
100Hz
9.999MHz
1kHz
+1.5% of rdg + 4 dgts
Sensitivity: 0.5V RMS min. while
≤
1MHz ;
Sensitivity: >3V RMS while
>
1MHz ;
Overload protection: 250V dc or ac rms.
Duty Cycle
Range
Resolution
Accuracy
0.1%~99.9%
0.1%
+1.2% of rdg + 2 dgts
Pulse width: >100us, <100ms;
Frequency width: 5Hz – 150kHz
Sensitivity: >0.5V RMS
Overload protection: 250V dc or ac rms.
Clamp DC Current
Range
Resolution
Accuracy
400A
0.1A
+1.0% of rdg +3dgts
(meter only, Clamp-on
Adaptor accuracy not
included)
Sensor: Clamp-on Adaptor (Note: not provide)
Overload protection: 250V dc or ac rms..
Clamp AC Current
Range
Resolution
Accuracy
400A
0.1A
+1.5% of rdg +3dgts
(meter only, Clamp-on
Adaptor accuracy not
included)
Sensor: Clamp-on Adaptor (Note: not provide)
Frequency Range: 50 to 400 Hz
Overload protection: 250V dc or ac rms..
9V Battery test
Range
Resolution
Accuracy
9V
10mV
+1.0% of rdg +3dgts
Test current : 6mA
Overload protection: 250V dc or ac rms..