background image

CODE

INFORMATION

WHAT TO DO

e -   0

Temperature within the heater too high.

Cool-down and re-ignite.

f -   0

Power interrupted.

Re-ignite the heater.

e -   1

Faulty thermostat.

Contact your dealer.

f -   1

Faulty burner thermistor.

Contact your dealer.

e -   2

Starting problems.

Contact your dealer.

e -   5

Tipping-over protection.

Re-ignite the heater.

e -   6

Poor burning.

Contact your dealer.

e -   7

Room temperature

If necessary,

above 32°C.

re-ignite the heater.

e -   8

Defective booster.

Contact your dealer.

e -   9

Air filter dirty; or

Clean filter

Fuel pump dirty.

Contact your dealer.

-- : --

Out of fuel.

Refill removable tank.

(& blinking
FUEL-light)

-- : --

Too little ventilation.

Ventilate better.

(& blinking
VENT-light)

Always contact your dealer for any malfunctioning not listed above.

AUTOMATIC CLEANING MODE

When the heater has been burning continuously for two hours at its highest

setting, the burner will automatically start an autoclean procedure. The display

will show the autocleaningcode 

cl:05

running back to 

cl:01

. The procedure takes 5

minutes, during which the heater will burn at its lowest setting, while the burner

autocleans. When the burner is clean again, the heater will automatically switch

back to the highest setting again.

I

CHILDPROOF LOCK

The childproof lock can be used to prevent children accidentally changing the

heater settings. When the heater is burning and the childproof lock is on, the

heater can only be switched off. Other functions are blocked then. If the heater

has already been switched off, the childproof lock also prevents accidental

ignition of the heater.

Activate the childproof lock by pressing the appropriate key 

N

and holding it down

for more than 3 seconds. The KEY-LOCK indicator light will light up (Fig. I),

indicating that the childproof lock has been activated. Switch off the childproof lock

by pressing the key 

N

and holding it down for more than 3 seconds once again.

J

THE CORRECT USE OF 'SAVE'

The 'SAVE' function allows you to limit the temperature. When this function is

activated, the heater will automatically switch off, when the room temperature

exceeds the set temperature by 3°C. Subsequently, when the room temperature has

dropped again to the set temperature, the heater will automatically switch on again. 

Activate the 'SAVE' setting by pressing the appropriate 

Q

key. The SAVE indicator

light will light up (Fig. J). Switch off the function by pressing the SAVE key once

again.

4

48

In case of any

malfunctioning the

information display will

tell you what is the

matter.

I: When the KEY-LOCK

light lights up, the

childproof lock has been

activated.

J: When the SAVE light

lights up, the heater will

automatically switch on

or off in order to remain

within a specified

temperature range.

Summary of Contents for SRE 270 TC

Page 1: ...TC 3 2 6 5 4 1 MANUEL D UTILISATION GEBRAUCHSANWEISUNG BRUGSANVISNING INSTRUCCIONES DE USO OPERATING MANUAL ISTRUZIONI D USO GEBRUIKSAANWIJZING INSTRUKCJA OBSŁUGI KULLANIM KILAVUZU 2 12 22 32 42 52 62 72 82 TR ...

Page 2: ...E E E E E E E E E E E E E E E E E E E E E E E E ...

Page 3: ...se read these Directions for Use first to ensure maximum lifetime for your Zibro Your heater comes with a 24 month manufacturer s warranty on all defects in material or workmanship We wish you much warmth and comfort with your Zibro Yours sincerely PVG International b v Customer Service Department 1 READ THE DIRECTIONS FOR USE FIRST 2 IN CASE OF ANY DOUBT CONTACT YOUR ZIBRO DEALER 3 BEFORE YOU STA...

Page 4: ... up all the remaining fuel in the heater MAIN COMPONENTS Front plate Grid Base plate Lid for removable tank Operation panel Handle Removable tank Air filter cap Vent filter Thermostat Plug cord Information display key Childproof lock Adjustment keys time and temperature TIMER SAVE key Indicator lights Connection Weektimer A B C 4 E F G H I J K L M N O P Q R S E E E E E E E E E E E E E E E E E E E ...

Page 5: ...our heater has been designed for use with high quality water free pure paraffin oil such as Zibro Extra or Zibro Kristal Only fuels of this kind will ensure clean and proper burning Lower quality fuel may result in E increased possibility of malfunctioning E incomplete burning E reduced heater lifetime E smoke and or smells E deposits on the grid or mantle Using the right fuel is therefore essenti...

Page 6: ...ts AC 50 Hz and set the correct time using the adjustment keys O refer to Section C Your heater is now ready for use B FILLING FUEL Do not fill the removable tank in the living room but in a more suitable place there can always be some spillage Follow the procedure below Make sure that the heater is switched off Open the lid 4 and lift the removable tank 7 out of the heater Fig B Note Some drops m...

Page 7: ...switch into the stand by position When the heater has been unplugged for more than 10 minutes or after a power failure the time needs to be set again D IGNITING THE HEATER When used for the first time a new heater may give out a smell for a short while You should therefore provide extra ventilation Just press the button M to ignite the heater The button will start blinking indicating that the igni...

Page 8: ...m will have been heated to approximately the required temperature at the set time When you want to switch off the heater and ignite it again with the timer all you have to do is press the TIMER key refer to Section G Press the button M once to clear the timer setting G SWITCHING OFF THE HEATER There are two ways to switch off the heater Press the button M The information display will show the CLOC...

Page 9: ...o prevent children accidentally changing the heater settings When the heater is burning and the childproof lock is on the heater can only be switched off Other functions are blocked then If the heater has already been switched off the childproof lock also prevents accidental ignition of the heater Activate the childproof lock by pressing the appropriate key N and holding it down for more than 3 se...

Page 10: ...tional ventilation the heater will switch off automatically after some time If the indicator light continues blinking after extra ventilation please contact your dealer M MAINTENANCE Switch off the heater and let it cool down before you start any maintenance work Also disconnect the plug from the mains Your heater needs hardly any maintenance It is however important that you clean the air filter c...

Page 11: ...ank G from the heater and remove the fuel filter refer to Section M Fig N Some drops may leak from the filter keep a cloth at hand Store the fuel filter and the removable tank outside the heater Place the transportation cap into the position of the fuel filter Fig O Press it tight Always move the heater in an upright position P SPECIFICATIONS Ignition electrical Dimensions mm width 704 Fuel paraff...

Page 12: ...ely In case of emergency you may use a fire extinguisher but only a type B extinguisher a carbon dioxide or powder extinguisher 10 TIPS FOR SAFE USE 1 Make sure that children are always aware of the presence of a burning heater 2 Do not move the heater when it is burning or still hot Do not refill nor service the heater when it is burning or still hot 3 Position the front of the heater at a distan...

Page 13: ...E E E E E E E E E E E E E E E E E E E E E E E E M E G D F H B A C I K J N P Q R O L S ...

Page 14: ...nd Oy Piispantilankuja 6C 02240 ESPOO tel 358 9 4390 030 fax 358 9 4390 0320 email appliance appliance group com FIN 4 UNITED KINGDOM Scott Brothers Ltd The Old Barn Holly House Estate Cranage Middlewich CW10 9LT UK tel 44 1606 837787 fax 44 1606 837757 email sales scottmail co uk ITALIA PVG Italy SRL Via Niccolò Copernico 5 50051 CASTELFIORENTINO FI tel 39 0 571 628 500 fax 39 0 571 628 504 email...

Reviews: