Without the 'SAVE' setting your heater will maintain the set temperature by

approximation as well, by adjusting its heating capacity. 'SAVE' is an economy

setting, which you can use when, for instance, you are not present in the room

or to keep it frost-free.

K

THE 'FUEL' INDICATOR LIGHT

When the FUEL indicator light lights up, there is enough fuel left for another 10

minutes of heater use. The count-down of the remaining heating time can be seen

in the information display 

L

(Fig. K). Every two minutes an alarm signal is

sounded, warning you to refill the removable tank. If you do not react, the heater

will extinguish by itself. The heater will also sound a warning signal, when it

switches off. The FUEL indicator light will blink, while four lines are blinking in the

information display. You can stop this by pressing the 

button 

M

once.

Once the heater has used up all its fuel and extinguished, it will take some time,

after the refill, before the heater is completely ready for use again.

L

THE 'VENT' INDICATOR LIGHT

When the VENT indicator light starts blinking, this is a sign that the room is not

vented sufficiently (Fig. L). If you do not provide additional ventilation, the heater

will switch off automatically after some time.

If the indicator light continues blinking after extra ventilation, please contact your

dealer.

M

MAINTENANCE

Switch off the heater and let it cool down, before you start any maintenance

work. Also disconnect the plug from the mains.

Your heater needs hardly any maintenance. It is, however, important that you

clean the air filter cap 

8

and the vent filter 

9

with a vacuum cleaner and the grid

with a damp cloth, both on a weekly basis. Remove the air filter cap

occasionally (Fig. M) and clean it with soapy water. Prior to reinstallation, make

sure that the air filter cap has fully dried. 

Regularly inspect the fuel filter as well:

Remove the removable tank 

7

from the heater and remove the fuel filter 

(Fig. N). Some drops may leak from the filter; keep a cloth at hand.

Remove the dirt by tapping the fuel filter upside-down against a hard surface. 

(Never clean it with water!)

Reinstall the fuel filter into the heater.

We recommend that you remove dust and stains in time with a damp cloth,

because otherwise these may cause stains that are hard to remove.

3

2

1

4

49

Fuel filter

L: A blinking VENT

indicator light is a sign

that you need extra

ventilation.

K: When the FUEL

indicator light is lit, the

information display will

show the number of

minutes of fuel left in 

the tank.

N

M

Summary of Contents for SRE 270 TC

Page 1: ...TC 3 2 6 5 4 1 MANUEL D UTILISATION GEBRAUCHSANWEISUNG BRUGSANVISNING INSTRUCCIONES DE USO OPERATING MANUAL ISTRUZIONI D USO GEBRUIKSAANWIJZING INSTRUKCJA OBSŁUGI KULLANIM KILAVUZU 2 12 22 32 42 52 62 72 82 TR ...

Page 2: ...E E E E E E E E E E E E E E E E E E E E E E E E ...

Page 3: ...se read these Directions for Use first to ensure maximum lifetime for your Zibro Your heater comes with a 24 month manufacturer s warranty on all defects in material or workmanship We wish you much warmth and comfort with your Zibro Yours sincerely PVG International b v Customer Service Department 1 READ THE DIRECTIONS FOR USE FIRST 2 IN CASE OF ANY DOUBT CONTACT YOUR ZIBRO DEALER 3 BEFORE YOU STA...

Page 4: ... up all the remaining fuel in the heater MAIN COMPONENTS Front plate Grid Base plate Lid for removable tank Operation panel Handle Removable tank Air filter cap Vent filter Thermostat Plug cord Information display key Childproof lock Adjustment keys time and temperature TIMER SAVE key Indicator lights Connection Weektimer A B C 4 E F G H I J K L M N O P Q R S E E E E E E E E E E E E E E E E E E E ...

Page 5: ...our heater has been designed for use with high quality water free pure paraffin oil such as Zibro Extra or Zibro Kristal Only fuels of this kind will ensure clean and proper burning Lower quality fuel may result in E increased possibility of malfunctioning E incomplete burning E reduced heater lifetime E smoke and or smells E deposits on the grid or mantle Using the right fuel is therefore essenti...

Page 6: ...ts AC 50 Hz and set the correct time using the adjustment keys O refer to Section C Your heater is now ready for use B FILLING FUEL Do not fill the removable tank in the living room but in a more suitable place there can always be some spillage Follow the procedure below Make sure that the heater is switched off Open the lid 4 and lift the removable tank 7 out of the heater Fig B Note Some drops m...

Page 7: ...switch into the stand by position When the heater has been unplugged for more than 10 minutes or after a power failure the time needs to be set again D IGNITING THE HEATER When used for the first time a new heater may give out a smell for a short while You should therefore provide extra ventilation Just press the button M to ignite the heater The button will start blinking indicating that the igni...

Page 8: ...m will have been heated to approximately the required temperature at the set time When you want to switch off the heater and ignite it again with the timer all you have to do is press the TIMER key refer to Section G Press the button M once to clear the timer setting G SWITCHING OFF THE HEATER There are two ways to switch off the heater Press the button M The information display will show the CLOC...

Page 9: ...o prevent children accidentally changing the heater settings When the heater is burning and the childproof lock is on the heater can only be switched off Other functions are blocked then If the heater has already been switched off the childproof lock also prevents accidental ignition of the heater Activate the childproof lock by pressing the appropriate key N and holding it down for more than 3 se...

Page 10: ...tional ventilation the heater will switch off automatically after some time If the indicator light continues blinking after extra ventilation please contact your dealer M MAINTENANCE Switch off the heater and let it cool down before you start any maintenance work Also disconnect the plug from the mains Your heater needs hardly any maintenance It is however important that you clean the air filter c...

Page 11: ...ank G from the heater and remove the fuel filter refer to Section M Fig N Some drops may leak from the filter keep a cloth at hand Store the fuel filter and the removable tank outside the heater Place the transportation cap into the position of the fuel filter Fig O Press it tight Always move the heater in an upright position P SPECIFICATIONS Ignition electrical Dimensions mm width 704 Fuel paraff...

Page 12: ...ely In case of emergency you may use a fire extinguisher but only a type B extinguisher a carbon dioxide or powder extinguisher 10 TIPS FOR SAFE USE 1 Make sure that children are always aware of the presence of a burning heater 2 Do not move the heater when it is burning or still hot Do not refill nor service the heater when it is burning or still hot 3 Position the front of the heater at a distan...

Page 13: ...E E E E E E E E E E E E E E E E E E E E E E E E M E G D F H B A C I K J N P Q R O L S ...

Page 14: ...nd Oy Piispantilankuja 6C 02240 ESPOO tel 358 9 4390 030 fax 358 9 4390 0320 email appliance appliance group com FIN 4 UNITED KINGDOM Scott Brothers Ltd The Old Barn Holly House Estate Cranage Middlewich CW10 9LT UK tel 44 1606 837787 fax 44 1606 837757 email sales scottmail co uk ITALIA PVG Italy SRL Via Niccolò Copernico 5 50051 CASTELFIORENTINO FI tel 39 0 571 628 500 fax 39 0 571 628 504 email...

Reviews: