background image

J

THE 'FUEL' INDICATOR 

When the FUEL indicator appears, there is enough fuel left for another 10 minutes

of heater use. The count-down of the remaining heating time can be seen in the

information display 

K

(Fig. J). Every two minutes an alarm signal is sounded,

warning you to refill the removable tank. If you do not react, the heater will

extinguish by itself. The heater will also sound a warning signal, when it switches

off. The FUEL indicator will blink, while four lines are blinking in the information

display. You can stop this by pressing the 

button 

L

once.

Once the heater has used up all its fuel and is extinguished it will take some time,

after the refill, before the heater is completely ready for use again.

K

THE 'VENT' INDICATOR

When there is insufficient ventilation in the room, an intermittent buzzer will be

heard (approximately once each 30 seconds) and the VENT indicator will be lit. When

this signal is given, ensure that the ventilation of the room is improved (e.g. by

opening a door or window a little more), to avoid that the heater shuts off. When the

ventilation of the room is improved, the VENT indicator and buzzer will be

deactivated. When there is still insufficient ventilation, the heater shuts off

automatically. When this occurs,  

e -1 1

is displayed and the VENT indicator is blinking.

After improving the ventilation of the room (e.g. by opening a door or window a little

more), the heater can be ignited by pushing the 

button 

L

again.

L

MAINTENANCE

Switch off the heater and let it cool down, before you start any maintenance

work. Also disconnect the plug from the mains. Your heater needs hardly any

maintenance. It is, however, important that you clean the vent filter 

8

with a

vacuum cleaner and the grid 

with a damp cloth, both on a weekly basis.

Regularly inspect the fuel filter as well:

Remove the removable tank 

6

from the heater and remove the fuel filter 

(Fig. L). Some drops may leak from the filter; keep a cloth at hand.

Remove the dirt by tapping the fuel filter upside-down against a hard surface. 

(Never clean it with water!)

Reinstall the fuel filter into the heater.

We recommend that you remove dust and stains from time to time with a damp

cloth, because otherwise these may cause stains that are hard to remove.

Do not remove any heater components yourself. Always contact your dealer for

repairs. When the power cord is damaged, it may only be replaced by an

authorised fitter. Use a new cord of the type H05 VV-F.

3

2

1

4

59

L

Fuel filter

J: When the FUEL

indicator has appeard,

the information display

will show the number of

minutes of fuel left in 

the tank.

K: A blinking VENT

indicator is a sign that

you need extra

ventilation.

Summary of Contents for SRE 139R E

Page 1: ...6 5 4 u 1 FIN MANUEL D UTILISATION GEBRAUCHSANWEISUNG BRUGSANVISNING INSTRUCCIONES DE USO K YTT OHJE OPERATING MANUAL ISTRUZIONI D USO BRUKSANVISNING GEBRUIKSAANWIJZING BRUKSANVISNING 2 12 22 32 42 5...

Page 2: ...s produits de combustion Contr le de la qualit de la combustion absence de CO Endurance Intermittence CONSEILS D UTILISATION ET D ENTRETIEN Se reporter la notice jointe l appareil et la plaque de s cu...

Page 3: ...ons for Use first to ensure maximum lifetime for your heater Your heater comes with a 24 month manufacturer s warranty on all defects in materials or workmanship We wish you a warm and comfortable tim...

Page 4: ...remaining fuel in the heater MAIN COMPONENTS Front plate Grid Base plate Lid for removable tank Operation panel Removable tank Fuel gauge removable tank Vent filter Thermostat Plug cord Information di...

Page 5: ...room is smaller than the specified space always put a window or door slightly ajar 2 5 cm We also recommend doing this in highly insulated or draught free rooms and or at altitudes above 1 500 metres...

Page 6: ...keys N refer to Section C Your heater is now ready for use B FILLING FUEL Do not fill the removable tank in the living room but in a more suitable place there can always be some spillage Follow the pr...

Page 7: ...to the stand by position When the heater has been unplugged or after a power failure the time needs to be set again D IGNITING THE HEATER When used for the first time a new heater may give out a smell...

Page 8: ...e key on the right Mmin to set the minutes interval of 5 minutes After approximately 10 seconds the 4 digit will show CLOCK again and the TIMER lamp Q will light up indicating that the timer function...

Page 9: ...tinuous operation The following will then appear in the display If desired you can switch the heater on again by pressing the button L see section D AUTOMATIC CLEANING MODE When the heater has been bu...

Page 10: ...ally When this occurs e 1 1 is displayed and the VENT indicator is blinking After improving the ventilation of the room e g by opening a door or window a little more the heater can be ignited by pushi...

Page 11: ...e the transportation cap into the position of the fuel filter Fig M Press it tight Always move the heater in an upright position O SPECIFICATIONS Ignition electrical Dimensions mm width 334 Fuel paraf...

Page 12: ...extinguisher but only a type B extinguisher a carbon dioxide or powder extinguisher 10 TIPS FOR SAFE USE 1 Make sure that children are always aware of the presence of a burning heater 2 Do not move t...

Page 13: ...K N L O M A E Q 6 B C 8 J R 4 7 P 9 E E E E E E E E E E E E E E E E E E E E E E E E...

Page 14: ...e zibro com SUOMI Appliance Finland Oy Piispantilankuja 6C 02240 ESPOO tel 358 9 4390 030 fax 358 9 4390 0320 email appliance appliance group com F FI IN N 4 UNITED KINGDOM Scott Brothers Ltd The Old...

Reviews: