Connect the cable to the indoor unit (for SC 30xx models)
1.
4.5 Meter cable for electrical connection between indoor and outdoor unit is delivered with the pac-
kage and is included in the refrigerant piping sleeve.
2.
The electrical cable is provided with an electrical quick connector.
3.
The outdoor unit is also provided with electrical quick connector.
4.
Connect the electrical quick connectors.
Connect the green/yellow earthing wire separately to the connection spot marked with
.
Connect the cable to the indoor unit (for S 30xx models)
1.
Indoor/Outdoor connection cable should be H07RN-F type.
2.
Remove the panel and screw, then remove the window cover. (fig. 21)
3.
Connect cables according to their marks to terminals. (fig. 22)
4.
Wrap those cables not connected with terminals with insulation tapes, so that they will not touch any
electrical components.
5.
Fit the power cord clamp.
Fig. 21
Fig. 22
Connect the cable to the outdoor unit (for SC 30xx models)
1.
The connection cables of indoor and outdoor units have been connected to the terminals on the con-
trol board except the grounding wire (Y/G), only white plug connectors exposed.
2. Remove the control cover from the outdoor unit by loosening the screw.
3.
Hold the indoor plug connector and insert the mating plug connector located on the outdoor unit until
it fixed with a clicking sound. Secure the cable onto the control board with the cord clamp.
4.
Connect the grounding wire to the terminal on the control board individually.
5.
The electrical connection is finished now.
10mm
40mm
L N S
L N S
40mm
L
S
N
10mm
Terminal block of indoor unit
Cord clamp
To outdoor unit
To outdoor unit
<3.0 kW
≥
3.0 kW
instal_S(C)30xx.qxd 19-07-2010 13:33 Pagina 77