background image

4

7

Remote Control

S1731 - S1735

S1753

G

NOTE

• 00:00 A.M. – 12:00 A.M. = 00:00 – 12:00

• 00:00 P.M. – 12:00 P.M. = 12:00 – 24:00

Sends signals to the receiver of the indoor
unit.

Indicates the fan speed selected by the fan
speed button. When set at “AUTO”, the fan
speed changes automatically according to
the difference between the designated tem-
perature and the room temperature.

Indicates the current operating mode

Indicates the present time or the timer.

ON: The air conditioner starts operation at

the designated time.

OFF: The air conditioner stops operation at

the designated time.

Indicates the temperature set by the tempe-
rature setting buttons.

Lights up when a signal is sent.

The setting temperature increases 
by 1°C (1.8°F) per press.

The setting temperature decreases 
by 1°C (1.8°F) per press.

Holding a button changes the temperature
setting quickly.

Air flow direction can be changed horizontal-
ly (upward and downward) by each press.

a

TRANSMITTER

b

FAN SPEED
INDICATION

c

OPERATION MODE
INDICATION

d

TIME DISPLAY

e

TIMER MODE 
INDICATOR

f

TEMPERATURE 
INDICATION 

g

TRANSMITTING 
INDICATION 

h

TEMPERATURE
SETTING BUTTONS

i

LOUVER BUTTON 

Air flow direction can be changed vertically
with swing movement (right and left) by
each press.

Generates negative ions. For the inverter
models only, the power indicator lights up
red.

Use to adjust the fan speed. The indication
of the fa speed varies among “L” (Low),
“M” (Medium), “H” (High), and “AUTO”
each time the button is pressed.

Use to change the operating mode. The
indication of the operating mode varies
among

(Automatic),

(Cooling),

(Dry),

(Circulating) and 

(Heating) each time the button is 

pressed.*

Press the “TIME ADJ” button to adjust the
present time or the timer.

Press these buttons to adjust the present
time or the timer.

Forward time

Backward time

Holding a button changes the time setting
in 10-minute intervals.

Press these buttons to turn the timer ON or
OFF.

Press this button for the Sleep setting.

Starts operation with a press: stops opera-
tion with the next press.

j

IONIZER BUTTON
(S1731 - S1735)

k

FAN SPEED BUTTON

l

OPERATION MODE
BUTTON

m

TIME ADJ BUTTON

n

,

BUTTONS

o

TIMER FIXING
BUTTONS

p

SLEEP BUTTON

q

ON/OFF BUTTON

j

VERTICAL LOUVER
BUTTON (S1753)

man_S17xx.qxd  06-02-2008  14:23  Pagina 7

Summary of Contents for S1731

Page 1: ...S1731 S1735 S1753 4 1 TR OPERATING MANUAL GEBRUIKSAANWIJZING KULLANIM KILAVUZU 2 22 42...

Page 2: ...uality product that if used responsibly will give you many years of pleasure Please read these instructions for use first in order to ensure the maximum life span of your airconditioner On behalf of t...

Page 3: ...3 CONTENTS A Safety instructions 4 B Parts and functions 5 C Before operation 8 D Instructions for use 9 E Air filter 16 F Cleaning 16 G Trouble shooting 18 H Guarantee conditions 19 I Technical data...

Page 4: ...move the plug of the unit from the wall socket when it is not in use A damaged power cord or plug must always be replaced by a recognised electrician or your supplier Do not operate or stop the aircon...

Page 5: ...echin filter Inlet grill Vertical louver Horizontal louver Remote signal receiver Outlet The air flow direction can be adjusted with the vertical and horizontal louvers Beeping sound assures successfu...

Page 6: ...ailure during operation operation status before power failure is memorized 3 4 minutes after power recovery the unit restarts automatically with previous operation status memorized 3 4 minutes is prot...

Page 7: ...ON d TIME DISPLAY e TIMER MODE INDICATOR f TEMPERATURE INDICATION g TRANSMITTING INDICATION h TEMPERATURE SETTING BUTTONS i LOUVER BUTTON Air flow direction can be changed vertically with swing moveme...

Page 8: ...quipped with a 3 in 1 air filter Photo catalytic catechin filter to clean the circulated room air Anti Dust Screening dust and large particles in the air Anti Odor Deodorizing bad smells from cigarett...

Page 9: ...J button once 2 Adjust the time with buttons Holding a button changes time set ting in 10 minute intervals 3 Press the TIME ADJ button 3 times The present time appears on the dis play The setting is c...

Page 10: ...eed changes automatically Cooling heating dry operation 1 Press the ON OFF button 2 Set the operation mode to Cooling Heating or Dry by pressing the operation mode button 3 Adjust the setting temperat...

Page 11: ...mode button G NOTE If the unit operates in cooling or dry for a long time in high humidity i e windows and doors are opened dew and water drops may form on the indoor unit Be aware that falling drops...

Page 12: ...conditioner is operating 1 Press the ON OFF button 2 Press the ionizer button To stop negative ion operation press the ionizer button Air flow adjustment Horizontal adjustment all models When the ON...

Page 13: ...zontal louver will come to a halt if the vertical louver button is pressed once again Timer operation Before setting the timer confirm that the present time is set accurately Once you set the timer th...

Page 14: ...ed for 2 seconds and then the present time appears Cancelling ON Timer Press the Timer fixing button ON The timer lamp of the indoor unit goes off OFF Timer Example Set the Off Timer to 10 p m Operati...

Page 15: ...setting temperature drops 0 6 C after 30 minutes of Sleep Timer ON and drops 0 6 C again after 30 minutes of the first temperature drop Emergency and test operation Emergency Operation The emergency o...

Page 16: ...is air conditioner is equipped with a 3 in 1 filter to clean the circulated room air a Anti Dust Screening dust and large particles in the air b Anti Odor Deodorizing bad smells from cigarette acetald...

Page 17: ...the filters are completely behind the stopper If the filter is not attached correctly it may cause defects 4 Close the front panel Maintenance of the negative ion generator twice a year only S1731 S1...

Page 18: ...igerant changes direction During the dry mode operation air may not flow out to prevent excessive cooling During the heating operation air does not flow out until the air is heated enough to prevent c...

Page 19: ...guarantee 5 The guarantee is valid only when you present the original dated purchase invoice and if no modifica tions have been made 6 The guarantee is invalid for damage caused by neglect or by actio...

Page 20: ...38 558 588 690 630 Voor ruimtes tot m3 75 100 85 110 130 150 Compressor type Rotary Rotary Rotary Ventilatorsnelheden 3 3 3 Thermostatisch bereik C 16 30 16 30 16 30 Werkingsgebied C 1 43 1 43 1 43 Ha...

Page 21: ...vironmental information This equipment contains fluorinated greenhouse gases covered by the Kyoto Protocol It should only be serviced or dismantled by professional trained personnel This equipment con...

Page 22: ...390 030 fax 358 9 4390 0320 email appliance appliance group com F FI IN N 4 UNITED KINGDOM Scott Brothers Ltd The Old Barn Holly House Estate Cranage Middlewich CW10 9LT UK tel 44 1606 837787 fax 44 1...

Reviews: