4 The timer function enables you to switch the device on/off after a certain time. The
operating time can be set between 1 and 24 hours with the -button. Every time you
press the button, the running time is extended by 1 hour. This will be shown on the
display. When the pre-set time has elapsed, the device will switch off.
When setting the timer when device is “ON”: the device will switch “OFF” once the pre-set
time has elapsed.
When setting the timer when device is “OFF”: the device will switch “ON” once the pre-set
time has elapsed.
(timer setting is not memorised in case of power failure)
5 Press the -button to turn the device off. The louver will close.
CHANGING THE MODE.
Use the -button to toggle between
- continuous dehumidifying mode
- automatic mode
- fan speed mode
When toggled to continuous dehumidification mode the
-symbol will blink. Press the
setting button to confirm. When in continuous drainage mode the display will show the
icon permanently and the device will dehumidify continuously.
When toggled to automatic mode the -symbol will be lit. In this mode the required
relative humidity can be changed by using the setting button .
The required set relative humidity is confirmed by pressing the mode button , or by
waiting for 3 seconds. The -symbol will now be shown permanently.
When in fan mode the
-symbol will be lit.
In this mode the fan speed can be changed between high speed and low speed by pressing
the “setting button” .
The required fan speed is confirmed by pressing the “mode” button , or by waiting for 3
seconds.
IN AUTOMATIC MODE:
When room relative humidity is below the by user set humidity the compressor will turn
off and the fan speed will turn to “low” speed. In this case the device is not dehumidifying.
When ambient temperature is detected to be above 32°C the fan speed will turn to “high”
speed.
AUTOMATIC DEfROSTING:
For protection against freezing of the inside of the device at room conditions below 16°C
the device is equipped with an automatic defrosting function: the dehumidifier, will
automatically have a 7 minute defrost cycle every other 25 minutes.
During defrost operation the device is not dehumidifying, the compressor is shut off, the
fan is running at high speed and the display will show .
AUTO RESTART fUNCTION
When power supply is interrupted while the dehumidifier is working, the working mode