![Zhone zNID-GPON-2402 Configuration Manual Download Page 173](http://html2.mh-extra.com/html/zhone/znid-gpon-2402/znid-gpon-2402_configuration-manual_3626256173.webp)
Deployment scenarios
zNID 24xx Series Configuration Guide
173
Figure 133: Selecting port members and their tagging
Normally the uplink
(Fiber WAN (eth0)
will be Tagged as in this
example. Select
T
from the
Fiber WAN (eth0)
dropdown.
In this example we are only selected one untagged downstream
interface. Select
U
from the
GE2 - GigE (eth2)
dropdown.
For Dual Managed connections that map to the VEIP select “O” for
the uplink port member.
b
Click
Save/Apply
c
From the
VLAN | Settings
page click
Edit Port Defaults
d
In the
PVID
text box for
GE2 - GigE eth2
, enter 205 (the same as the
ID for the VLAN)
Figure 134: Setting the PVID for the interface
Summary of Contents for zNID-GPON-2402
Page 12: ...About This Guide 12 zNID 24xx Series Configuration Guide...
Page 18: ...zNID 24xx Series 18 zNID 24xx Series Configuration Guide...
Page 84: ...Management 84 zNID 24xx Series Configuration Guide Figure 57 View audit log...
Page 199: ...VLANS zNID 24xx Series Configuration Guide 199 Figure 157 Configuration of VLAN settings...
Page 208: ...Configuration 208 zNID 24xx Series Configuration Guide...
Page 220: ...Troubleshooting tests 220 zNID 24xx Series Configuration Guide...
Page 223: ...Voice zNID 24xx Series Configuration Guide 223 Voice Figure 175...
Page 226: ...Index 226 zNID 24xx Series Configuration Guide...