Preparing for installation
22
SkyZhone 1624, 1424, 1224 Hardware Installation Guide
WARNING!
The unit is sealed at the factory and must not be
opened in the field. The unit shall be returned to the factory
for repairs.
•
SkyZhone product requires professional installation.
•
This equipment has been tested and found to comply with the limits for a
Class C digital device, pursuant to part 15, subpart C, of the FCC rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
user manual, may increase the potential for harmful interference to radio
communications.
•
The SkyZhone-1424 equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which the user will be required to
correct the interference at his own expense.
WARNING!
The authority to operate SkyZhone-1424
equipment is conditioned by the requirement that no
modifications will be made to the equipment unless the
changes or modifications are expressly approved by the
manufacturer.
•
The PoE (Power over Ethernet) connector sources power to other devices.
Some devices may not be compatible with this feature. In that case, do not
connect the wires that supply the power. The power is 48 volts DC, at a
maximum of 5 watts.
•
This unit can only be used with approved antennas that are shipped with
the unit. Antennae should be kept at least 10 inches away from contact
with the general public passing by the area.
•
Proper grounding of the SkyZhone platform must be completed before
you connect power to the unit.
–
The internal subassemblies signal/Logic ground is internally bonded
to the Safety Ground (chassis).
–
SkyZhone provides both Primary and Secondary lightning and surge
protection to the SHDSL and PoE cable signals. The Console cable
signals are not protected and this cable, which is not intended for
outdoor use, should not be connected when the unit is installed.