4-62
IMACS System Release 5.1.9
Reference Guide
Model No.
Running Head
Testing Voice Cross-Connects
System Configuration and Operation
Figure 4-42. Typical Test Screen and ABCD Bit Options
Table 4-6. WAN Cross-Connect Test Screen Options
Tx ABCD BITS
The Transmit ABCD bit parameter has two options:
mon
(allowing you to observe the bit
pattern being sent on the transmit side of the line), and
set
(to choose a different pattern for
testing that portion of the circuit). Choosing
set
brings up a small four-character window at
the bottom of the screen, where you can type in a new pattern of ones and zeros.
Figure 4-43 shows a diagram of the test process. When Tx ABCD for w2-1 is set to
mon
, the
w2-1 column reflects the ABCD bits being sent out on w2-1. This pattern should be identical
to Rx ABCD on w2-2, unless the conversion table is used. When Tx ABCD for w2-1 is
Parameter
User Options
Default
Tx ABCD
mon set
mon
PATTERN
off all 0 all 1 m_oos 1:1 1:7 lpbk 300Hz
1KHz 3KHz
off
MON Tx ABCD
information only–no user options
MON Rx ABCD
information only–no user option
CONVERSION
information only–no user option
TYPE
information only–no user option
WAN STATE
information only–no user option