4
NOTE 1: Never pull the hose to move the unit. This could damage hose and/or pump inlet.
NOTE 2: Water source must provide a minimum of 5 gallons per minute at 20 p.s.i. Inlet hose can connected to the water main with
Max. inlet pressure 1MPa.
NOTE 3: Use cold water only and water
’s temperature shall not exceed 50
℃
.
5)
Turn water source on.
6)
The diameter of the nozzle is
1.15mm.Turn knob clockwise and anticlockwise in order to get pencil jet and 0~40
°
fan jet.
EXPLANATION:
0° Nozzle- Used for a pinpoint stream. This nozzle stream is very powerful and covers a very small area of cleaning. This nozzle
should only be used on surfaces that can this high pressure such as metal or concrete.
15° and 25
°
Nozzle-Used for less powerful steam which can cover a wider area. This nozzle is also very powerful and should
only be used on surfaces that can withstand this high pressure.
40
°
Nozzle-Used for the least powerful stream and covers a wide area of cleaning. This nozzle should be used for most general
cleaning jobs.
5.3 Operation:
NOTE: Do not let hoses come in contact with the HOT engine muffler during or immediately after use, as this will destroy the hose.
1) press the trigger safety lock, and then you can press the trigger
2) Start engine according to the engine owner
’s manual.
3) Press the trigger of high pressure gun to make sure water flowing out. Be careful when press the trigger gun, it has recoil force
and the sudden torque. Release the trigger of high pressure gun can stop the water flowing out.
In emergency condition: Turn engine off.
5.4 Pressure Meter:
When you operate the unit, you can read the value of rated pressure and permissible pressure from pressure meter. (see picture 1)
5.5 Shut Down Procedure
1.
Release the trigger can stop the water flowing out.
After did this, pls. engage the trigger safety lock to avoid accidental “switch
on”.
In emergency condition: turn engine off immediately .
2.
Turn engine off. See Engine Owner
’s Manual. NOTE: NEVER turn the water off with the engine running.
3.
Turn water source off.
4.
Press trigger to release residual water.
5.
Disconnect all hoses used
6.
See storage section in this manual for proper storage procedures. Note: Let the engine cool and up to 30 minutes after use
before touching.