Installation and Operating Instructions V02
47
9.1.2 Control button
The inverter has a control button which is necessary to switch between the various
displays for measured values and data, enter next entry and lock the expected
information.
The display menus wrap around, which means that when you arrive at the last entry,
the first entry is displayed when you press the button again.
You can freeze the display as follows:
Press the button for 5s when it shows the information you desire, and do not release
the button until you see ‛LOCK“. The display will show the selected information until
you press the button again or the operating state of the inverter changes.
To save power, the backlight of the display turns off automatically after 10s. Press the
button again to activate it.
9.1.3 LEDs
The inverter is equipped with three LED indicators ‛green“, ‛red“ and ‛yellow“ which
provide information about the various operating states.
Green LED:
The green LED is lit when the inverter is operating normally.
Yellow LED:
The yellow LED flashes during communication with other devices e.g.
ZeverCom/ZeverManager, Solarlog etc. Also, the yellow LED flashes during updating
firmware through RS485.
Red LED:
The red LED is lit when the inverter has stopped feeding power into the grid due to a
fault. The corresponding error code will be shown on the display.