Pinout detail of the RJ45 interface on the inverter as follows:
Pin1------- TX_RS485A
Pin2-------TX_RS485B
Pin3-------RX_RS485A
Pin4-------GND
Pin5-------GND
Pin6-------RX_RS485B
Pin7-------+7V
Pin8-------+7V
For detailed information, please refer to ZeverManager user manual.
CAT-5 with shield or higher level cable is required as the RS485 communication
cable between inverter and ZeverManager. Pinout detail on both ends of the cable
should comply with IA/TIA568A or 568B standard.
The cable shall be UV resistant if used outdoors.
Connect the network cable:
Damage to the inverter due to moisture and dust penetration
• If the cable gland are not mounted properly, the inverter can be
destroyed due to moisture and dust penetration. All the warranty
claim will be invalid.
• Make sure the cable gland has been tightened firmly.