background image

Installation 

2.8 

Connecting the foot pedals 

• 

Connect the foot pedals “glass plate up” and “glass plate down” [29] at the rear 
side of the book cradle (refer to blue resp. red color margins). 

• 

To avoid unwanted disconnection of the cables, the round plugs have a thread. 
Please tighten them manhandled 

2.9 

Connecting the power cords 

• 

Connect the power cord [30] to the drive unit at the appropriate socket at the 
back side of the book cradle 

• 

Connect the power cord [31] to the appropriate socket at the back side of the 
book cradle and the other end to a mains socket  

 

 

   

The scanner might be operated at 220-230V AC at 50/60 Hz only! 

   

For other voltages use a power converter! 

 

• 

For switching on and off the power of the scanner use the mains switch [32] 

 

 

 

29

32

31

30

 Fig. 

14 

 

12

 

Summary of Contents for OMNISCAN 10000 TT

Page 1: ...OMNISCAN 10000 TT Installation Manual TS 0351E 15 09 03 ZEUTSCHEL GmbH Heerweg 2 D 72070 Tübingen Hirschau Germany ...

Page 2: ...of the glide runners 7 2 5 Connecting the cables at the scanner 8 2 5 1 SCSI cable 8 2 5 2 Control cable SubD and power supply cable AMP 9 2 6 Adjusting the support screw 10 2 7 Connections to the PC 11 2 8 Connecting the foot pedals 12 2 9 Connecting the power cords 12 3 FIRST START 13 3 1 Application hints for switching on and off the scanner 13 3 2 Installation of the scanner software 13 4 MANU...

Page 3: ...on the reflector mirror please observe the Zeutschel cleaning recommendation in the user manual TS 0366E before start cleaning 1 2 Components The delivery consists of the following components see Fig 1 and Fig 2 1 OT 2 book cradle with power cord 2 column red with drive unit 3 Scan unit with SCSI Terminator 4 Dongle 5 Software CD ROM 6 Installation and user manuals 7 Foot pedal 2x book cradle 1x e...

Page 4: ...ight has to be avoided A location with indirect illumination is recommended The table top unit has to be put on a sturdy table 1 4 Required tools Hexagon key 5mm Combination wrench 7mm Combination wrench 12mm Combination wrench 17mm cotton gloves for the installation of the reflector Phillips screwdriver 4 ...

Page 5: ... the case Put the book cradle on a table or a suitable base 2 2 Fixing the column Place the column at the rear side against the book cradle Install the 4 allen screws 8 at the back side of the book cradle like shown in Fig 3 Do not yet fix the screws too firmly Insert the two dowel pins carefully Fig 3 horizontal arrows into the marked drill holes 9 If necessary drive them carefully in with a hamm...

Page 6: ...o persons It should be moved over the fixing plate 11 at the drive unit 12 by turning it a little bit from front to back Do not touch the mirror s surface with your fingers support it at the metal frame Slide the four threaded pins into the designated holes 13 at fixing plate The reflector should be positioned downwards until it touches the supporting edge 14 13 14 11 12 Fig 4 10 Fig 5 6 ...

Page 7: ...lector and tighten them like shown in Fig 6 and Fig 7 Fig 6 15 15 16 16 Fig 7 2 4 Checking the position of the glide runners The glide runners 16 should glide properly down the support rails Please check the position after each transport installation of the scanner 7 ...

Page 8: ...SCSI terminator 18 at the rear left hand side of the reflector and tighten the fixing screws manhandled Fig 8 Do not use a screw driver the fixing screws might be damaged Fix the strain relief 19 metal plate with the two M3 fixing screws 20 at the bracket below the SCSI terminator Fig 9 16 18 17 Fig 8 20 20 19 Fig 9 8 ...

Page 9: ...bD plug 22 at the rear right hand side of the reflector Tighten the fixing screws at the SubD manhandled Fig 10 Do not use a screw driver the fixing screws might be damaged Fix the strain relief 23 metal plate with the two M4 fixing screws 24 at the bracket below the SubD socket Fig 11 22 21 Fig 10 24 23 Fig 11 9 ...

Page 10: ...ut 26 the support screw can be adjusted with a combination wrench 12mm by turning it up or downwards Turn the adjustment screw upwards until it is levitating Then turn it downwards until it hits the table and stabilizes the book cradle against waggling You should avoid lifting the scanner with the adjustment screw it should only support the book cradle Tighten the counter nut finally 26 25 Fig 12 ...

Page 11: ...Graphics adapter Min Resolution Pentium IV AMD Athlon 1GHz 2GHz recommended SCSI UW 68 pin Adaptec 39320 R 512MB 1GB recommended 16MB 1024x768 24bit Connect the SCSI cable 27 to the SCSI controller socket at your PC Adaptec 39320 R Connect the foot pedal exposure to the COM 1 interface 28 of your PC 9 pin SubD connector Fig 13 27 28 11 ...

Page 12: ...hem manhandled 2 9 Connecting the power cords Connect the power cord 30 to the drive unit at the appropriate socket at the back side of the book cradle Connect the power cord 31 to the appropriate socket at the back side of the book cradle and the other end to a mains socket The scanner might be operated at 220 230V AC at 50 60 Hz only For other voltages use a power converter For switching on and ...

Page 13: ...kes i e several minutes it is not recommended to switch off the scanner When starting the scanner switch on the scanner mains switch first and then boot up your PC When switching the scanner off you should always shut down first your PC and then switch off the scanner s mains switch When the scanner is under power you will hear a low fan noise coming from the drive unit 3 2 Installation of the sca...

Page 14: ...0 Tübingen GERMANY Tel 49 0 7071 9706 0 Fax 49 0 7071 9706 44 e mail info zeutschel de http www zeutschel de 4 2 Service In case of confusion our troubles with our products you are welcome to get in touch with our support Please contact your local ZEUTSCHEL dealer or the ZEUTSCHEL customer service 14 ...