Your Zeta smoke alarm chirps intermittently

• Check the location of your smoke alarm 

(see ‘Application & Positioning’).

• Check that your smoke alarm is definitely 

the source of chirping; make sure the 

noise isn’t coming from another alarm 

(smoke/carbon monoxide/burglar/gas 

alarm) by process of elimination.

Your Zeta smoke alarm activates when no 

smoke is visible

• Check the location of your smoke alarm 

(see the section on ‘Positioning’).

• Clean the smoke alarm (see the section 

on ‘Routine Maintenance’).

• For ZD-SI-610 smoke alarm only remove 

build-up of static electricity by wiping your 

Zeta smoke alarm with a slightly damp 

cloth.

You experience frequent unwanted alarms

• Check the location of your Zeta smoke 

alarm (see the section on ‘Positioning’).

• Clean the smoke alarm (see the section 

on ‘Routine Maintenance’).

• ZD-SI-610 Only: Remove buildup of static 

electricity by wiping your smoke alarm 

with a slightly damp cloth. 

• If the frequent unwanted alarms continue 

contact technical support for advice. 

Summary of Contents for ZD-SI-610/ZD-SO-610

Page 1: ...ZD SI 610 ZD SO 610 User Manual 10 YEAR LIFE 10 YEAR LIFE TOAST PROOF SMOKE ALARM...

Page 2: ...Normal Condition Low Power Pack Condition ALARM TEST ALARM SMART SILENCE ROUTINE MAINTENANCE WHAT TO DO IN CASE OF FIRE IN YOUR HOME REPAIR TROUBLESHOOTING DISPOSAL HOW TO MAKE YOUR HOME SAFER WARRANT...

Page 3: ...s in position prior to attaching the alarm INTRODUCTION This user manual covers the following two products Zeta ZD SI 610 Ionisation Smoke Alarm and ZD SO 610 Toast Proof Optical Smoke Alarm Congratul...

Page 4: ...t be used as a substitute for a hard wired system as required in new build properties In this type of property the building regulations require alarms to be interlinked You can obtain further informat...

Page 5: ...are facilities long term health care facilities boarding houses and dormitories Your smoke alarm can be used in individual sleeping resident rooms providing the same conditions are met as for a single...

Page 6: ...particles from cooking in kitchens will result in unwanted alarms and permanent contamination of the smoke alarm s sensor In areas where excessive dust or dirt could contaminate the sensing chamber m...

Page 7: ...danger We recommend that as a minimum you install both ionisation and optical smoke alarms on every floor of your property For comprehensive coverage a smoke alarm should also be fitted in every room...

Page 8: ...t hearing impaired residents WARNING The smoke alarm accompanying this manual employs the latest technology and is independently tested as being compliant with all the relevant British Standards Howev...

Page 9: ...ensure the mounting plate is aligned correctly The mounting plate has an arrow moulded into the plastic This indicates the orientation in which the mounting plate should be installed This ensures that...

Page 10: ...ck into place Once the smoke alarm has been fitted onto the mounting plate the internal power pack will activate The red LED on the front of the alarm should now flash once every 40 seconds to show th...

Page 11: ...rm immediately Your Zeta smoke alarm will continue to warn of this low power pack condition for at least 7 days however failure to change the alarm after this time would mean your smoke alarm has insu...

Page 12: ...r immediate attention Only use the alarm silence function after making sure that there is no ongoing fire emergency situation Do not block the vents on the alarm or disable the smoke alarm in any way...

Page 13: ...LED will revert to flashing once every 40 seconds DANGER Never ignore any alarm Ignoring the alarm may result in injury or death If your smoke alarm activates and alarms and you are not absolutely cer...

Page 14: ...ings you must do to keep it working properly CAUTION Your Zeta smoke alarm is a sealed electrical device and no attempt should be made to open the case Attempting to open the case will invalidate your...

Page 15: ...sed their chances of escaping safely Go over the following rules with your children each time you have fire drills This will help everyone remember them in case of a real emergency Don t panic stay ca...

Page 16: ...your warranty If your smoke alarm is not operating properly see the next section Troubleshooting If you cannot solve the problem please call the Technical Support Line If your Zeta smoke alarm is no l...

Page 17: ...the test button firmly If the unit has been silenced is in low sensitivity mode it may not test Wait 15 minutes then try again If the alarm has been recently fitted and it still fails to self test the...

Page 18: ...alarm see the section on Positioning Clean the smoke alarm see the section on Routine Maintenance For ZD SI 610 smoke alarm only remove build up of static electricity by wiping your Zeta smoke alarm...

Page 19: ...ght If you have any questions about the operation of your alarm please contact the Zeta Technical Support Team between 9am 5pm Monday Friday Telephone 44 0 1792 455 175 or e mail support zetaalarmsyst...

Page 20: ...Installing smoke alarms is only one step in protecting your family from fires You must also take steps to reduce the chances of fires starting in your home If a fire does start you must increase your...

Page 21: ...smoke alarm signal and knows how to react to it If there are small children to consider it is important to explain to them what the smoke alarm signal means Teach them that they must be prepared to le...

Page 22: ...ernative product similar to that being replaced if the original model is no longer available or in stock This warranty applies to the original retail purchaser from the date of original retail purchas...

Page 23: ...team member will issue you with a returns authority number so that your product can be returned for testing To return your Zeta smoke alarm under warranty send it suitably packed and with the battery...

Page 24: ...23 NOTES...

Page 25: ...24 GN0504 R2...

Page 26: ...zetaalarmsystems com Web www zetaalarmsystems com ZD SI 610 ZD SO 610 GN0504 R2 Certificate No 330j 02 to BS EN 14604 2005 ZD SI 610 Certificate No 330j 04 to BS EN 14604 2005 ZD SO 610 Zeta Alarm Sy...

Reviews: