All outputs unavailable
General error
Please check if there is a
power outage. Then, check
the upstream distribution box
circuit breaker. If the outputs
are still unavailable please
contact authorized service.
The status information LED
blinks in red
You shall see this error
notification if your vehicle is
equipped with a battery type
that requires ventilation.
This charging station is not
suitable to charge such
vehicles.
7.2 - TRIPPING RELAY ON PRODUCTS WITH RESIDUAL CURRENT DEVICE CAUTION
You may access the residual current device by opening the front cover of your charging station. If
your charging station does not have RCCB reclosure unit, ensure that there is no failure on your
vehicle or on the charging plug that may cause a residual current before resetting the tripped
residual current device. After ensuring that there is no problem on your vehicle or on the charging
plug, unplug the charging cable from the charging station. Then reactivate your charging station
by resetting the switch of RCCB.
If the problem still occurs, contact an authorized service. If the problem is solved, there may be
some problem with your vehicle or charging cable. Please contact with your vehicle service.
7.3 - DC 6mA LEAKAGE CURRENT SENSOR BEHAVIOR
The charging station is equipped with a DC leakage current sensor that reacts a DC leakage cur-
rent higher than 6mA. If the charging station goes to error state due to DC leakage current, charg-
ing cable must be unplugged from vehicle and then from the charging station to reset this error.