4 - CIRCUIT BREAKER and OTHER CRITICAL COMPONENT LOCATIONS
•
See section “Opening front covers in product installation guideline to open the front cover.
•
If any RCCB and/or MCB is tripped, check the insulation of the related outlet. Then, turn on
the RCCB and/or MCB as shown in the figure below.
5 - BEHAVIOUR OF THE STATUS INFORMATION LEDs (for AC Type2 outlets)
Status of the LED
Status of the Charging Station
No LED Indication
Standby
Blue Glowing
Charging
Constant Blue
Charging Suspended or Finished
Constant Red
Fault
4 sec
Ventilation Required
Blinks Red; 2,4 seconds OFF 1,2 seconds
ON
Park Automation System disabled
charging
Constant Purple
Charging paused due to power
optimizer low current limit or EVC
low current limit
Constant Purple
4 sec
Charging cable connected and
waiting for authorization
Blinks Blue; 2,4 seconds OFF 1,2 secon-
ds ON
Authentication while vehicle is in
not connected state (timeout: 30
seconds)
Green Glowing
4 sec
Configuration Mode
Blinks Red; 1 second OFF 1 second ON
Twice
User rfid card added to list
Blinks Green twice; 500 ms ON 500 ms
OFF
4 sec
User rfid card removed from list
Blinks Red twice; 500 ms ON 500 ms
OFF
4 sec
Unregistered rfid card tapped
Blinks Red three times; 500 ms ON 500
ms OFF