2 • Carel Controller - Programming Instructions
CAREL CONTROLLER
CAREL CONTROLLER
3-5 DOOR LOW TEMP
LEVEL 1
Code
Name
Factory
Set
St
Set point
-10
rd
Differential
6
dl
Defrost interval
12
dt1
Defrost end temp
70
dP1
Defrost duration
40
d/1
Defrost probe temp
(actual)
tc.y
RTC year
-
tc.m
RTC month
-
tc.d
RTC day of month
-
tc.u
RTC day of week
-
tc.h
RTC hour
-
tc.m
RTC minute
-
LOW TEMP
LEVEL 2
Code
Name
Factory
Set
/A2
Probe 2 confi guration
2
c1
Min time between starts
5
c2
Min comp OFF
1
c3
Min comp ON
1
d0
Defrost type
4
dd
Drip time
1
dn
Defrost duration %
100
AL
Low temp alarm
-20
AH
High temp alarm
10
F0
Fan management
2
F1
Fan start temp
30
H0
Serial address
1
H1
Function of relay 4
10
td1.d
Defrost time day 1
11
td1.h
Defrost time hour 1
8
td1.m
Defrost time minute 1
0
td2.d
Defrost time day 2
11
td2.h
Defrost time hour 2
20
td2.m
Defrost time minute 2
0
65-0703 Rev G
IM BOTTOM-MOUNTED COIL
LEVEL 1
Code
Name
Factory
Set
St
Set point
7
rd
Differential
4
dI
Defrost interval
12
dt1
Defrost end temp
70
dP1
Defrost duration
40
d/1
Defrost probe temp
(actual)
tc.y
RTC year
-
tc.m
RTC month
-
tc.d
RTC day of month
-
tc.u
RTC day of week
-
tc.h
RTC hour
-
tc.m
RTC minute
-
IM BOTTOM-MOUNTED COIL
LEVEL 2
Code
Name
Factory
Set
/A2
Probe 2 confi guration
2
c1
Min time between starts
5
c2
Min comp OFF
1
c3
Min comp ON
1
d0
Defrost type
4
dd
Drip time
1
dn
Defrost duration %
100
AL
Low temp alarm
-20
AH
High temp alarm
25
F0
Fan management
2
F1
Fan start temp
30
H0
Serial address
1
H1
Function of relay 4
10
td1.d
Defrost time day 1
11
td1.h
Defrost time hour 1
8
td1.m
Defrost time minute 1
0
td2.d
Defrost time day 2
11
td2.h
Defrost time hour 2
20
td2.m
Defrost time minute 2
0
65-1093 Rev B
ZERO ZONE, INC. • 800-247-4496 • ZERO-ZONE.COM
© 2015 Zero Zone, Inc. All Rights Reserved. • MAR 2015
MN-10-C
Low Temp Codes
1 & 2 DOOR LOW TEMP
LEVEL 1
Code
Name
Factory
Set
St
Set point
-10
rd
Differential
6
dI
Defrost interval
12
dt1
Defrost end temp
45
dP1
Defrost duration
30
d/1
Defrost probe temp
(actual)
tc.y
RTC year
-
tc.m
RTC month
-
tc.d
RTC day of month
-
tc.u
RTC day of week
-
tc.h
RTC hour
-
tc.m
RTC minute
-
1 & 2 DOOR LOW TEMP
LEVEL 2
Code
Name
Factory
Set
/A2
Probe 2 confi guration
2
c1
Min time between starts
5
c2
Min comp OFF
1
c3
Min comp ON
1
d0
Defrost type
0
dd
Drip time
1
dn
Defrost duration %
100
AL
Low temp alarm
-20
AH
High temp alarm
10
F1
Fan start temp
30
H0
Serial address
1
H1
Function of relay 4
10
td1.d
Defrost time day 1
11
td1.h
Defrost time hour 1
8
td1.m
Defrost time minute 1
0
td2.d
Defrost time day 2
11
td2.h
Defrost time hour 2
20
td2.m
Defrost time minute 2
0
65-1372 Rev A