Carel Controller - Programming Instructions • 3
CAREL CONTROLLER
CAREL CONTROLLER
Medium Temp Codes
ZERO ZONE, INC. • 800-247-4496 • ZERO-ZONE.COM
© 2015 Zero Zone, Inc. All Rights Reserved. • MAR 2015
MN-10-C
MEDIUM TEMP
LEVEL 1
Code
Name
Factory
Set
St
Set point
34
rd
Differential
4
dt1
Defrost end temp
50
dP1
Defrost duration
30
d/1
Defrost probe temp
n/a
tc.y
RTC year
-
tc.m
RTC month
-
tc.d
RTC day of month
-
tc.u
RTC day of week
-
tc.h
RTC hour
-
tc.m
RTC minute
-
MEDIUM TEMP
LEVEL 2
Code
Name
Factory
Set
/A2
Probe 2 confi guration
0
c1
Min time between starts
5
c2
Min comp OFF
1
c3
Min comp ON
1
d0
Defrost type
2
dl
Defrost interval
12
dd
Drip time
1
dn
Defrost duration %
100
AL
Low temp alarm
30
AH
High temp alarm
50
F0
Fan management
0
F1
Fan start temp
5
H0
Serial address
1
H1
Function of relay 4
10
td1.d
Defrost time day 1
11
td1.h
Defrost time hour 1
8
td1.m
Defrost time minute 1
0
td2.d
Defrost time day 2
11
td2.h
Defrost time hour 2
20
td2.m
Defrost time minute 2
0
65-0704 Rev F