AIR FILTER CLEANING

MALFUNCTION DIAGNOSIS

Trouble Shooting Tips

E0 Error Code.

E1 Error Code

Unit does not cool well

The unit is noisy

and vibrates too

much

The unit makes a gurgling 

sound

Unit stops frequently

Communication failure between driver 

board and control board.

Temperature sensor error.

The air conditioner doesn’t work at 

COOL or STRONG mode.

The air filter is blocked 

with dust or animal hair.

Exhaust hose is not 

connected or is blocked.

The unit is low on refrigerant.

The windows and doors in the 

room are open.

The room area is too large.

There are heat sources inside 

the room.

The floor is not level.

The air filter is blocked with 

dust or animal hair.

This sound is caused by the flow of 

refrigerant inside the unit.

The exhaust hose is blocked, 

extended or otherwise restricted.

Contact the consumer service.

Contact the consumer service.

Set the working mode to COOL or STRONG mode.

Turn off the unit and clean the filter according 

to instructions.

Turn off the unit, disconnect the hose, check for 

blockage and reconnect the hose.

Contact the consumer service.

Make sure all windows and doors are closed.

Double-check the cooling area.

Remove the heat sources if possible.

Place the unit on a flat, level surface.

Turn off the unit and clean the filter according to 

instructions.

This is normal.

Remove the exhaust hose to see if the unit 

continues to operate. If yes, shorten the extension, 

reduce the number of bends or eliminate restriction.

•Always unplug the unit before cleaning or servicing.

•DO NOT use flammable liquids or chemicals to clean the unit.

•DO NOT wash the unit under running water. Doing so causes electrical danger.

•DO NOT operate the machine if the power supply was damaged during cleaning. A damaged power cord must be 

  replaced with a new cord from the manufacturer.

•Always clean the unit using a damp, lint-free cloth and mild detergent. Dry the unit with a dry, lint-free cloth.

•Drain the unit's water collection tray by tilting the machine backwards.

•After draining the water run the unit on FAN mode for 12 hours in a warm room to dry it and prevent mold.

•Turn off the unit and unplug it.

•Clean the air filter . Always reinstall the clean, dry filter before  storing.

Care and Cleaning

Symptom

Possible Cause

Solution

Summary of Contents for MARK 2 Series

Page 1: ...bject to change without prior notice for product improvement Consult with your dealer or manufacturer for details Video Tutorial Visit our official website to watch a video tutorial at www zerobreeze...

Page 2: ...ncluded accessories and specified parts for installation Using nonstandard parts can cause water leakage electrical shock fire and injury or property damage DO NOT allow children to play with the air...

Page 3: ...chased separately please refer to the zerobreeze com for more details The cooling speed and maximum working time are measured under the experimental environment and are for reference only Mark2 alread...

Page 4: ...use a third party adapter Mark 2 can be battery operated or operated with the power adapter USE YOUR MARK 2 Tutorial on Operating with the included Adapter Tutorial Battery Operation Connect battery i...

Page 5: ...re that the end of the hose is facing down to allow the water to flow smoothly ACCESSORY CONNECTION Drain pipe connection instructions LED1 LED2 LED3 LED4 LED5 Current power 0 20 20 40 40 60 60 80 Ful...

Page 6: ...rly USE ENVIRONMENT Make sure that you install your unit on an even surface to minimize noise and vibration If using with a power adapter the unit must be put near a grounded plug When Mark 2 is worki...

Page 7: ...rcular holes with a diameter of 11cm the distance of 15cm between each hole Use a utility knife to remove the excess If the width is not enough cut out some other foam and stitch it together Choose th...

Page 8: ...kage and reconnect the hose Contact the consumer service Make sure all windows and doors are closed Double check the cooling area Remove the heat sources if possible Place the unit on a flat level sur...

Reviews: