background image

03

04

The Mark2 is equipped with a new 24V high-performance compressor, and the outlet temperature can be lower than 
the ambient temperature of 28

 in 10 minutes. The new dual-hose exhaust system improves space cooling speed by 

40% over the first generation. The classic handle design makes it easy to move. Using Mark2's special battery can 
achieve a maximum continuous working time of about 5 hours.

GETTING TO KNOW THE MARK 2

Power Button

•When power on, press once to turn on, then press to turn off.

•After the unit is stopped, the compressor cannot be restarted for one minute. This is to protect the equipment.

STRONG mode

Press the "STRONG" mode button, the 
indicator lights up, and the other mode 
lights go out.

The air conditioner enters the STRONG 
mode and works at full load. The air 
conditioner status indicator is blue.

SLEEP mode

Press the SLEEP mode button, the 
indicator lights up, and the other mode 
lights go out.

The air conditioner enters SLEEP mode 
and works at low load. The air 
conditioner status indicator is blue.

LIGHT button

Press the LIGHT button, the indicator 
light is on, the front light is on, and 
press it again, the light is off.

When the air conditioner is powered on, 
there is no need to turn on the air 
conditioner, and the lighting can be 
turned on or off.

Alternative function Long press for 3 
seconds, air outlet temperature display 
switch between Fahrenheit and Celsius.

Unplug the plastic sheet and use the 
remote control.

CONTROL PANEL&REMOTE CONTROL PANEL

1.Control Panel
2.Outlet air direction adjustment
3.Outlet air temperature display
4.Air filter
5.LED lights
6.Status light
7.Exhaust air outlet

8.Exhaust air inlet
9.Power input
10.Drain

Design and Compliance Notes 

* The batteries shown in this manual need to be purchased separately, please refer to the zerobreeze.com for more details.

** The cooling speed and maximum working time are measured under the experimental environment and are for reference only. 

***  Mark2 already contains a set of intake and exhaust hoses. If you need a longer hose, learn more from zerobreeze.com.

LIGHT

ON/OFF

SPEED

FAN

SLEEP

COOL STRONG

+Button

Increase blowing speed. 
*Alternative function

FAN mode

Press the FAN button, the FAN indicator is 
on, and the other modes are off.

When the air conditioner enters in FAN 
mode, the compressor and exhaust fan 
will be turned off after 5 seconds, and the 
air conditioner status indicator will 
change from blue to red.

When the FAN mode is switched to 
another mode, the compressor will have a 
protection delay of 1 minute before it 
starts to work.

COOL mode

The default cooling mode, when the power 
supply voltage is lower than 19V, the air  
conditioner will stop working automatically. 

Press and hold the cooling mode control 

button(hold for 2 seconds), Mark 2 will  
enter the car mode (tail indicator light will 

be purple).In this mode, when the  power 

supply voltage is lower than 22V, the air 
conditioner will automatically  power off to 
prevent the car battery from running out.

When the cooling mode button is pressed 
and hold for 2 seconds again, it switches  to 

the default cooling mode.

This setting has a memory function, that is, 

after unplugging the power supply,  when 
powered on next time it maintains the 

previous setting mode.

-Button

Decrease blowing speed
*Alternative function

 

1

2

3

4

6

8

7

9

10

5

LIGH

T

ON/OFF

SPEED

FA

N

SLEEP

COOL

STRONG

In order to ensure the optimal performance of our 

products, the design specifications of the unit and 

remote control are subject to change without prior 

notice.

The Energy Rating for this unit is based on the 

installation of two unextended exhaust ducts.

Long press to decrease temperature 
display brightness.

Long press to increase temperature 
display brightness.

Summary of Contents for MARK 2 Series

Page 1: ...bject to change without prior notice for product improvement Consult with your dealer or manufacturer for details Video Tutorial Visit our official website to watch a video tutorial at www zerobreeze...

Page 2: ...ncluded accessories and specified parts for installation Using nonstandard parts can cause water leakage electrical shock fire and injury or property damage DO NOT allow children to play with the air...

Page 3: ...chased separately please refer to the zerobreeze com for more details The cooling speed and maximum working time are measured under the experimental environment and are for reference only Mark2 alread...

Page 4: ...use a third party adapter Mark 2 can be battery operated or operated with the power adapter USE YOUR MARK 2 Tutorial on Operating with the included Adapter Tutorial Battery Operation Connect battery i...

Page 5: ...re that the end of the hose is facing down to allow the water to flow smoothly ACCESSORY CONNECTION Drain pipe connection instructions LED1 LED2 LED3 LED4 LED5 Current power 0 20 20 40 40 60 60 80 Ful...

Page 6: ...rly USE ENVIRONMENT Make sure that you install your unit on an even surface to minimize noise and vibration If using with a power adapter the unit must be put near a grounded plug When Mark 2 is worki...

Page 7: ...rcular holes with a diameter of 11cm the distance of 15cm between each hole Use a utility knife to remove the excess If the width is not enough cut out some other foam and stitch it together Choose th...

Page 8: ...kage and reconnect the hose Contact the consumer service Make sure all windows and doors are closed Double check the cooling area Remove the heat sources if possible Place the unit on a flat level sur...