D
AILY
Use the thermometer to check for the temperature of the cooling section and record the
temperature. The thermostat switch must be used to correct the temperature if it does not
correspond to the required value.
Refer to the section “Troubleshooting” if you do not obtain an acceptable result.
Check for the colour of the gas-flame, if the device is operated with gas. For optimum
performance the gas-flame colour must be blue. If it is not the case, the burner and the burner
head, respectively must be cleaned.
Check for the remaining gas in the gas cylinder.
Do always keep a filled gas cylinder in reserve.
Do always replace the gas cylinder before it is completely empty.
Store the vaccines according to the correct sequence, and make sure that air can circulate freely
between the individual packages.
Remove immediately any remaining liquids in the inner container.
W
EEKLY
Check for the ice layer on the evaporator. If the ice layer is thicker than 1 cm, the device must be
defrosted. (See section “Defrosting”)
Clean the lid sealing and verify that the lid is locking tightly.
M
ONTHLY
Use a soft brush to free the unit from dust.
Clean the device inside and outside. Use lukewarm water with a mild cleaning agent. Abrasive or
caustic cleaning agents, steel wood, scouring sponges, or chemical cleaning agents should in no
case be used. After the cleaning is finished, the device should be dried properly.
Clean the lid sealing.
Check the hinges and locks of tight fastening and very that the lid is locking tightly.
Verify that all gas line connections are free of leaks.
A
T
I
NTERVALS OF
6
M
ONTHS
Clean the gas burner and burner head.
A
LL REPAIR AND MAINTENANCE WORK MUST BE PERFORMED
BY APPROVED EXPERTS ONLY!
4 Icepacks can be frozen within 24 hours when the device is operated under normal conditions
(i.e. ambient temperature not exceeding 32°C) and with continuous cooling operation. Higher
ambient temperatures will only allow for less Icepacks to be frozen.
Fill the Icepacks corresponding to the accompanying figure.
Place the four Icepacks upright in the freezer section.
Page 7
R
OUTINE
M
AINTENANCE
E