Z3N/Z3NU/Z3NN/Z3NNU/Z3NW/Z3NWU 75-100
Cable routing
29
www.zepro.com
Image 45. Battery capacity and definition of the length of the earth and main power cables
-
+
-
+
L
L
U
min
I
min
I
min
U
min
5.2
Sizing electrical systems
Ensure that the battery and charger capacity is sufficient for the product in question and that cable with suf
-
ficient cross-sectional area is used.
NOTE!
Make sure the tail lift has access to the minimum recommended current capacity (I
min
)
.
Some vehicle models have restrictions regarding the amount of current the lift can access from the existing
battery. Some vehicle models do not fully charge the battery. It may therefore be necessary to switch to a
battery and sometimes also to a charger with a larger capacity.
NOTE!
Make sure the lift has
access to the minimum
recommended current ca-
pacity (I
min
)
.
Some vehicle
models have restrictions
regarding the amount of
power the lift can access
from the existing battery.
(160 bar)
5910
12 volt
Pump - Motor unit
115 A
Magnet (hydraulic unit)
1.4 A
Magnet (electric safety valve)
1.5 A
Solenoid
1.8 A
Minimum recommended conductor cross
sectional area
(copper cables, plus and minus cables)
Control cable
1.5 mm
2
Supply cable, L < 8 m
25 mm
2
Supply cable, L = 8 - 15 m
35 mm
2
Supply cable, L > 15 m
-
Battery
Min. capacity, I
min
140 Ah
Min. voltage during operation, U
min
(at lift)
9 volt
Summary of Contents for Z3N 75-100