background image

ZRC-0100 Recirculating Kit Instructions

2

To install the return air vent to top of the cabinet:

(for installations where cabinet does not extend to the ceiling)

Return Air Vent

Return Air Vent

6” round 

duct from 

AK8000AS

top of cabinet

FIG.1

FIG.2

FIG.3

airflow

airflow

top of cabinet

soffit or

ceiling

screw (1 in each corner

            of return air vent)

1.  Cut a 6-1/2” round opening in top of the

     cabinet where the ducting will connect

     to the return air vent. 

FIG.1 

 

2.  Connect 6” round ducting from AK8000AS to 

     return air vent collar.  Return air vent collar 

     will go around the ducing.  Secure with duct tape.

3.  Secure return air vent to top of cabinet with  

     (4) screws.

To install the return air vent to a soffit or ceiling:

(for installations where top of cabinet is flush with the ceiling)

1.  Cut a 6-1/2” round opening in soffit or ceiling

     where the ducting will connect to the return

     air vent. 

FIG.2

  

2.  Connect 6” round ducting from AK8000AS to 

     return air vent collar.  Return air vent collar 

     will go around the ducing.  Secure with duct tape.

3.  Secure return air vent to soffit or ceiling with  

     (4) screws.

note: 

Return air vent deflectors should face 

          the sides to properly vent the air.

 FIG.4

screw (1 in each corner

            of return air vent)