Touch Control
A – Lights Button:
Lights are two level (high, low). From stand-by-on mode,
touch once for high, twice for low, three times to cycle back.
B - Delay Off Button:
Press the Delay Off Button to enable the ten-minute
delay-off function, no matter at what speed the fan is running at. B button will
start blinking indicating the delay off function is enabled. After ten minutes the
fan and lights will turn off. Delay off function can be disabled by pressing B
button, changing the speed, or pressing the Power Button C.
C - Power Button:
Press once to activate all button stand by mode allowing
control of other button functions. All buttons will illuminate indicating stand by
mode. Press the Power Button again to turn the hood off (fan and lights). The
stand by mode will remain active for 30 seconds.
D - Low Speed Button:
In stand-by mode: Press once for low speed.
E - Medium Speed Button:
In stand-by mode: Press once for medium speed.
F - High Speed Button:
In stand-by mode: Press once for high speed.
MESH FILTER CLEAN REMINDER
(always enabled): after 60 hours of fan usage,
button A blinks when the hood is in stand-by, indicating it is time to clean the
mesh filters. To Reset the function: with the hood in stand-by, press and hold
the B button for 4 to 5 seconds, the A button will stop blinking, and the 60-
hour timer will reset.
CHARCOAL FILTER REPLACE REMINDER
(disabled by default, must be enabled
by user if recirculating hood): To enable Charcoal Filter Replacement Function
hold buttons D and F simultaneously for four seconds. The A button will quickly
flash 3 times indicating the Charcoal Filter Replacement Function is enabled. After
200 hours of fan usage, the B button will blink while the hood is on, indicating
it is time to replace the charcoal filters.
To Reset the Charcoal Filter Replace Reminder function: Hold the B button for 4
to 5 seconds until it stops flashing, and the 200-hour timer will reset.
Order replacement charcoal filter kit number Z0F-C011 through your local dealer,
www.zephyronline.com, or the Zephyr customer service department.
To disable the Charcoal Filter Replacement function, repeat the enable procedure,
the A button will illuminate for 3 seconds then turn off indicating the Charcoal
Filter Replacement Function is disabled.