background image

www.zephyronline.com

Im

p

o

rt

an

t

s

af

et

y

N

o

ti

c

e

2

TO RE DUCE TH E R IS K O F FIR E O R E LE C TR IC SHOC K, DO NOT US E TH IS FAN W ITH ANY S O LID-S TATE
SP E E D C O NTRO L DEV IC E.

TO RE DUCE TH E R IS K O F FIR E, E LE C TR IC SH O C K, O R INJU RY TO P E R SON S, O B S E RVE TH E FO LLO W ING:

a. Use this unit only in the manner intended by the manufacturer, If you have questions, contact the manufacturer.
b. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being

switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten a prominentwarning device, such as tag, to the service panel.

For General VentilatingUse Only. Do not Use to Exhaust Hazardous or Explosive Materials and Vapors.

TO REDUC E TH E R IS K O F A RA NG E TO P GR E AS E FIR E:

a. Never leave surface units unattendedat high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low

or mediumsettings.

b. Always turn hood ON when cooking at high heat or when cooking flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn

Beef Flambe)

c. Clean ventilatingfans frequently. Grease should not be allowed to accumulate on fan or filter.
d. Use proper pan size. Always use cookware appropriatefor the size of the surface element.

TO RE DU C E TH E R IS K O F INJURY TO P ERSON S

IN TH E EV E NT O F A RA NG E TO P G R E AS E FIR E, O B S E RVE TH E FO LLO W ING :

a. SM OTHE R F LA MES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. B E CARE FUL TO P R EV E NT BUR NS.

If the flames do not go out immediately,E VAC UATE AND CALL TH E FIR E DE PARTME NT.

b. NEV E R PIC K UP A F LAMI NG PAN - You may be burned.
c. DO NOT US E WATE R, includingwet dishcloths or towels - a violent steam explosion will result.
d. Use an extinguisher ONLY if:

1. You know you have a class AB C extinguisher, and you already know how to operate it.
2. The fire is small and contained in the area where it started.
3. The fire departmentis being called.
4. You can fight the fire with your back to an exit.
5. Based on “Kitchen Fire Sa fety Tips” published by NFPA.

TO R E DUC E TH E R IS K O F FIR E, E LE C TR IC SHOC K O R INJURY TO PER SONS, O B S E RVE TH E FO LLO W ING :

a. Installation Work and Electrical Wiring Must be Done by Qualified Person (s) In Accordance with all Applicable Codes and Standards,

Including Fire-Rated Construction.

b. Sufficient air is needed for proper combustionand exhausting of gases through the flue (chimney) of fuel burningequipmentto prevent back

drafting. Follow the heating equipmentmanufacturer’s guideline and safety standards such as those published by the National Fire Protection
Association (NFPA), and the American S ociety for Heating, Refrigeration, and Air ConditioningEngineers (AS H R AE) and the local code authorities.

c. When cutting or drillinginto wall or ceiling, do not damage electrical wiring and other hidden utilities.
d. Ducted fans must always vent to the outdoors.

TO REDUC E TH E R IS K O F FIR E, USE O NLY ME TAL DU C TW O R K.

To reduce risk of fire and to properly exhaust air, be sure to duct air outside - Do not vent exhaust air into spaces within walls or ceilings or into
attics, crawl spaces or garages.

Take care when using cleaning agents or detergents.Suitable for use in household cooking area.

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

CAUTION

CAUTION

READ AND SAVE THESE INSTRUCTIONS

WARNING

TO REDUCE THE RISK OF SHOCK, THIS FAN MUST BE INSTALLED WITH AN ISOLATING WALL CONTROL/SWITCH.

Summary of Contents for Venezia ZVE-E30S

Page 1: ...Venezia ZVE E30S ZVE E36S ZVE E42S Model number Serial number Use Care and Installation Guide MAY07 0101 Zephyr Corporation www zephyronline com...

Page 2: ...www zephyronline com...

Page 3: ...and Clearance Ducting Specifications Mounting the Hood and Duct Cover Ductless Recirculating FEATURES CONTROLS Touch Controls Features Charcoal Filter Change Indicator Metal Filter Clean Indicator MA...

Page 4: ...DE PARTME NT b NEV E R PIC K UP A FLAMING PAN You may be burned c DO NOT USE WATE R includingwet dishcloths or towels a violentsteam explosion will result d Use an extinguisher ONLY if 1 You know you...

Page 5: ...ct cover assembly 2 pieces 1 Hardware bag 1 Duct cover mounting bracket 1 Packet of mounting screws w anchors 1 Butterfly damper NO DUCTING IS INCLUDED Note Zephyr recommends using 50LB EZ anchors if...

Page 6: ...traight 1 Ft x Ft Subtotal column 1 Duct pieces Total Equivalent number length x used 6 Round wall cap with damper 30 Ft x Ft 7 Round wall cap with damper 30 Ft x Ft 7 Round 900 elbow 15 Ft x Ft 7 Rou...

Page 7: ...orksheet to compute total duct work ALWAYS when possible reduce the number or transitions and turns If long duct run is required increase duct size from 6 to 7 or 8 If a reducer is used install a long...

Page 8: ...l exhaust must be ducted to the outside unless using the recirculating option Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified S...

Page 9: ...evailing local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampe...

Page 10: ...THE DUCT COVER 1 Center and attach duct cover mount bracket on wall below ceiling or soffit 2 Mount telescopic duct covers onto hood and extend inner duct cover and fasten to bracket EZANC HO RS A B...

Page 11: ...tandard Metal Filters are intended to capture residue from cooking and the optional charcoal filters help to purify fumes exhausted from cooking for re circulation RECIRCULATING KIT Required Hood Mode...

Page 12: ...hes in the lower right hand side of display indicating the function is on The hood will completely shut down in 15 minutes 4 Lights On Off Dim Switch lights On and Off by pressing key once To dim ligh...

Page 13: ...hing when charcoal filter replacement is needed Setting the Filter Change Reminder When Off hold for approx 5 seconds The display will change from exhaust mode to purifying mode carbon filters used th...

Page 14: ...e Filters can be cleaned by hand with non abrasive soap or in a dishwasher Heavily soiled filters should also be soaked in grease cutting detergent such as Formula 409 or its equivalent prior to clean...

Page 15: ...nded to filter out residue and grease from cooking They need not be replaced on a regular basis but are required to be kept clean Filters should be cleaned after every 30 hours of use Use the Filter C...

Page 16: ...ff and bulbs are not hot Remove by turning bulb counter clockwise If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approx the diameter of the bulb or use a rubber...

Page 17: ...ct opening or ductwork 4 The direction of duct opening is against the wind 5 Using the wrong size of ducting 1 Metal filter is loose 1 Make sure the circuit breaker and the unit s power is ON 2 Check...

Page 18: ...M043 Telescopic Back Splash 30 Z0S 0013 Telescopic Back Splash 36 Z0S 0016 Telescopic Back Splash 42 Z0S 0012 Wire Spice Rack 30 Z0R 0013 Wire Spice Rack 36 Z0R 0016 Wire Spice Rack 42 Z0R 0012 To ord...

Page 19: ...ces outside of service area and the labor cost incurred in connection with the removal shipping and reinstallation cost nor does it cover any other contingent expenses The natural wear of finish and w...

Reviews: