Zephyr Venezia ZVE-E30S Use, Care And Installation Manual Download Page 12

www.zephyronline.com

10

F

eatures

&

Controls

-

T

ouc

h

Controls

&  F

eatures

The standard Metal Filters are required to be cleaned frequently and as recommended in order to maintain blower
efficiency. If improperly maintained, residue from cooking will sift though filters and cause damage to hood blowers
and other sensitive components; and possibly clog duct work and create a fire hazard.

1. Blower On/Off

By pressing     , the blower is switched On and Off. When switched on, the blower starts up on speed level 3.

2. Speed Selection

The 6 speed levels are selected by presing     to decrease and        to increase speed level.  The display indicates

level selected.

3. Delay Off

This is used for programmed shut down of blower and lights 15 minutes after the function is activated. Press      once,
a dot flashes in the lower right hand side of display         indicating the function is on. The hood will completely shut down
in 15 minutes.

4. Lights On/Off/Dim

Switch lights On and Off by pressing key        once. To dim lights, press and hold         for 2 seconds.

5. Advance Display Functions

Filters Clean Reminder (Metal):

After every 30 hours of use, the display will start flashing an              reminding you to clean the metal filters from residue and
possible clogs.

Filters Change Reminder (Charcoal, if fitted):

When your hood is installed as “Recirculating” (Ductless) unit, it is fitted with a set of Chacoal Filters to purify any
exhaust and fumes from cooking, and re-circulates the air within the home. These Charcoal Filters are required to be replaced
after every 120 hours of use. The

Filter Change Reminder

function in the microprocessor needs to be switched on. The

microprocessor in the controls when set, will elapsed and count usage time and indicate when charcoal filter replacement is
needed every 120 hrs.

Summary of Contents for Venezia ZVE-E30S

Page 1: ...Venezia ZVE E30S ZVE E36S ZVE E42S Model number Serial number Use Care and Installation Guide MAY07 0101 Zephyr Corporation www zephyronline com...

Page 2: ...www zephyronline com...

Page 3: ...and Clearance Ducting Specifications Mounting the Hood and Duct Cover Ductless Recirculating FEATURES CONTROLS Touch Controls Features Charcoal Filter Change Indicator Metal Filter Clean Indicator MA...

Page 4: ...DE PARTME NT b NEV E R PIC K UP A FLAMING PAN You may be burned c DO NOT USE WATE R includingwet dishcloths or towels a violentsteam explosion will result d Use an extinguisher ONLY if 1 You know you...

Page 5: ...ct cover assembly 2 pieces 1 Hardware bag 1 Duct cover mounting bracket 1 Packet of mounting screws w anchors 1 Butterfly damper NO DUCTING IS INCLUDED Note Zephyr recommends using 50LB EZ anchors if...

Page 6: ...traight 1 Ft x Ft Subtotal column 1 Duct pieces Total Equivalent number length x used 6 Round wall cap with damper 30 Ft x Ft 7 Round wall cap with damper 30 Ft x Ft 7 Round 900 elbow 15 Ft x Ft 7 Rou...

Page 7: ...orksheet to compute total duct work ALWAYS when possible reduce the number or transitions and turns If long duct run is required increase duct size from 6 to 7 or 8 If a reducer is used install a long...

Page 8: ...l exhaust must be ducted to the outside unless using the recirculating option Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified S...

Page 9: ...evailing local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampe...

Page 10: ...THE DUCT COVER 1 Center and attach duct cover mount bracket on wall below ceiling or soffit 2 Mount telescopic duct covers onto hood and extend inner duct cover and fasten to bracket EZANC HO RS A B...

Page 11: ...tandard Metal Filters are intended to capture residue from cooking and the optional charcoal filters help to purify fumes exhausted from cooking for re circulation RECIRCULATING KIT Required Hood Mode...

Page 12: ...hes in the lower right hand side of display indicating the function is on The hood will completely shut down in 15 minutes 4 Lights On Off Dim Switch lights On and Off by pressing key once To dim ligh...

Page 13: ...hing when charcoal filter replacement is needed Setting the Filter Change Reminder When Off hold for approx 5 seconds The display will change from exhaust mode to purifying mode carbon filters used th...

Page 14: ...e Filters can be cleaned by hand with non abrasive soap or in a dishwasher Heavily soiled filters should also be soaked in grease cutting detergent such as Formula 409 or its equivalent prior to clean...

Page 15: ...nded to filter out residue and grease from cooking They need not be replaced on a regular basis but are required to be kept clean Filters should be cleaned after every 30 hours of use Use the Filter C...

Page 16: ...ff and bulbs are not hot Remove by turning bulb counter clockwise If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approx the diameter of the bulb or use a rubber...

Page 17: ...ct opening or ductwork 4 The direction of duct opening is against the wind 5 Using the wrong size of ducting 1 Metal filter is loose 1 Make sure the circuit breaker and the unit s power is ON 2 Check...

Page 18: ...M043 Telescopic Back Splash 30 Z0S 0013 Telescopic Back Splash 36 Z0S 0016 Telescopic Back Splash 42 Z0S 0012 Wire Spice Rack 30 Z0R 0013 Wire Spice Rack 36 Z0R 0016 Wire Spice Rack 42 Z0R 0012 To ord...

Page 19: ...ces outside of service area and the labor cost incurred in connection with the removal shipping and reinstallation cost nor does it cover any other contingent expenses The natural wear of finish and w...