background image

22

Okeanito Guide d’utilisation, d’entretien et d’installation

M U R

D E S I G N E R

O K E A N I TO

Schéma de câblage

CBE-1000 6.2
PBN-1000A 5.1

VOLTS

120

HZ

60

BLANC

JAUNE

ROUGE

BLEU

VER

T

NOIR

BL

ANC

CORPS

NOIR

BLANC

NOIR

BL

ANC

BLEU

ROUGE

JA

UNE

PC de commande

LED

LED

LED

LED

pour 48 po seulement

NOIR

BLANC

BLANC

NOIR

L

L

B/W

SW

BLANC

Ampérage
maximal

Schéma de câblage du ventilateur interne

Remarques :Condensateur     15uF 370VCA ADAPTÉ CA120V 60Hz (CBE-1000)
                      Condensateur*2 25uF 250VCA ADAPTÉ CA120V 60Hz (PBN-1000A)

CORPS

VERT

BLANC

NOIR

BLEU

ROUGE

MOTEUR

COK-E36/42/48CSX

COK-E36/42/48CBGX

Summary of Contents for Okeanito COK-E36CBGX

Page 1: ...WWW ZEPHYRONLINE COM DEC21 0101 Okeanito COK E36CSX COK E42CSX COK E48CSX COK E36CBGX COK E42CBGX COK E48CBGX EN Use Care and Installation Guide FR Guide d utilisation d entretien et d installation...

Page 2: ...2 Okeanito Use Care and Installation Guide OKEANITO WALL DESIGNER...

Page 3: ...heet 8 Mounting Height Clearance Ducting 9 Ducting Options 10 Hood Specifications 11 Electrical Supply 12 Cable Lock 12 Internal Blower Preparation 13 Remote Blower Preparation 14 Mounting the Range H...

Page 4: ...ocked securely fasten a prominent warning device such as a tag to the service panel General Safety WARNING Warning means that failure to heed this safety statement may result in extensive product dama...

Page 5: ...ithin walls ceilings attics crawl spaces or garages WARNING WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring must...

Page 6: ...National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and...

Page 7: ...4 Swivel LumiLight LED 6W pre installed 48 model 2 4W mood LED bulbs 2 Telescopic duct covers 1 Duct cover ceiling bracket 1 Utensil rail 1 Wall mount hanging bracket 1 8 round starting collar with da...

Page 8: ...t Ft Ft 6 7 8 10 Round roof cap 30 Ft x Ft Subtotal column2 Subtotal column1 Total ductwork Maximum Duct Length For satisfactory air movement the totalductlengthshould not exceed 150 equivalent feet 6...

Page 9: ...hould be no higher than 36 It is important to install the insert at the proper mounting height Inserts mounted too low could result in heat damage and fire hazard while inserts mounted too high will b...

Page 10: ...al screws and tape all joints w certified Silver Tape or Duct Tape Fire Hazard NEVER exhaust air or terminate ductwork into spaces between walls crawl spaces ceilings attics or garages All exhaust mus...

Page 11: ...Specifications Front View Bottom View Top View Side View 95 22 3 4 Standard Duct Cover min 30 1 2 max 49 1 2 Z1C 00OK Extension min 44 max 77 6 10 5 1 8 4 1 4 36 26 1 16 42 26 1 16 48 41 21 36 5 42 8...

Page 12: ...this appliance Follow national electrical codes or prevailing local codes and ordinances This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch...

Page 13: ...ening 3 Position capacitor box inside hood body and secure by 2 M4 8 screws from internal blower hardware 5 Connect 9 pin molex connector from internal motor to 9 pin molex connector from capacitor ca...

Page 14: ...k and remote blower wiring harness through the remote blower wiring knockout Attach by 4 M4 8 screws 5 Connect 6 pin male connector from remote blower wiring to 6 pin female connector on control board...

Page 15: ...nting spread 8 11 16 from center line on line C FIG C 6 Place duct cover ceiling bracket onto ceiling and mark inside diameter of ceiling bracket Cut inside diameter of ceiling bracket to fit the 6 or...

Page 16: ...k of the hood body will rest between the wall and the top lip of the wall bracket Secure hood body in place by 2 M4 38 screws though bottom section of interior of hood body FIG E 12 Place telescopic d...

Page 17: ...s on The blower will completely shut down after 5 minutes 4 Lights Low Medium High Off Switch lights on to low by pressing once press a second time for medium press a third time for high and press aga...

Page 18: ...s of use Reset the filter clean reminder timer after filters are cleaned and re installed With hood off press and hold for approxi mately 5 seconds until on display disappears The filter clean reminde...

Page 19: ...inless steel polish cleaners to polish and buff out the stainless luster and grain Always scrub lightly with clean cotton cloth or micro fiber cloth and buff in the direction of the stainless steel gr...

Page 20: ...LED In the unlikely event that your swivel LumiLight LED fails please contact Zephyr to order replacement parts See the list of parts and accessories page for part numbers and contact information LED...

Page 21: ...MPS CBI 290C 0 8 CBI 390A 2 1 CBI 600A 2 6 REMARKS CONDENSER 3 uF 250V AC120V 60Hz CBI 290C CONDENSER 25uF 250V AC120V 60Hz CBI 390A CBI 600A WHITE YELLOW RED BLUE GREEN BLACK WHITE BODY BLACK WHITE B...

Page 22: ...W RED BLUE GREEN BLACK WHITE BODY BLACK WHITE BLACK WHITE BLUE RED YELLOW Control PC LED LED LED LED for 48 only BLACK WHITE WHITE BLACK L L B W SW WHITE CBE 1000 6 2 PBN 1000A 5 1 REMARKS CONDENSER 1...

Page 23: ...m detects if the blower is too hot to operate and shuts the blower down The blower will function properly after the thermally protected system cool down Damaged capacitor Change the capacitor Blower m...

Page 24: ...he cooktop and the bottom of the hood within 24 and 36 range The wind from the opened windows or opened doors in the surrounding area are affecting the ventilation of the hood Close all the windows an...

Page 25: ...ber Replacement Parts Baffle Filter each 50210036 LED Bulb 4W P12010008 Swivel LumiLight LED 6W Z0B0052 Optional Accessories Duct Cover Extension Z1C 00OK Single Internal Blower CBI 290C CBI 600A Exte...

Page 26: ...26 Okeanito Use Care and Installation Guide OKEANITO WALL DESIGNER Notes...

Page 27: ...to be eligible for warranty repairs or service Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LI...

Page 28: ...a moment to register your new Zephyr product at www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Prompt registration helps in more ways than on...

Page 29: ...WWW ZEPHYRONLINE COM DEC21 0101 Okeanito COK E36CSX COK E42CSX COK E48CSX COK E36CBGX COK E42CBGX COK E48CBGX EN Use Care and Installation Guide FR Guide d utilisation d entretien et d installation...

Page 30: ...2 Okeanito Guide d utilisation d entretien et d installation MUR DESIGNER OKEANITO...

Page 31: ...conduit d a ration 8 Hauteur de montage d gagement et gaine 9 Options de conduits 10 Sp cifications de la hotte 11 Fourniture lectrique 12 Raccord de c ble 12 Pr paration du ventilateur interne 13 Pr...

Page 32: ...Avant l entretien ou le nettoyage de l unit coupez l alimentation au panneau de service et verrouillez les moyens de d connexion de service pour viter toute mise sous tension accidentelle Lorsque le m...

Page 33: ...normes applicables y compris la construction r sistant au feu b Une quantit d air suffisante est n cessaire pour une combustion et une vacuation correctes des gaz par le conduit de fum e chemin e de...

Page 34: ...d quate et conforme au National Electrical Code ANSI NFPA 70 derni re dition ou aux normes CSA C22 1 94 Code canadien de l lectricit partie 1 et C22 2 No 0 M91 derni re dition et tous les codes et ord...

Page 35: ...t Z1C 00OK Pi ces fournies Quantit Partie 1 Hotte 1 Filtres chicanes mod les 36 po et 42 po 2 Filtres chicanes mod le 48 po 2 LumiLight LED pivotante 6W pr install mod les 36 po et 42 po 4 LumiLight L...

Page 36: ...bre utilis rect droit circ droit rect coude 90 rect coude 45 rect coude plat 90 circ coude 90 coude 45 Sous total colonne 1 Longueur maximale du conduit d a ration Pour un mouvement d air convenable l...

Page 37: ...installer la l insert la bonne hauteur de 24 po min 36 po max min C max D Standard Extension Hauteur de la hotte Duct Cover Duct Cover minimum A 30 1 2 po 44 po maximum B 49 1 2 po 77 po Hauteur du p...

Page 38: ...argent ou du ruban adh sif Risque d incendie NE JAMAIS vacuer l air ni terminer de conduits dans des espaces entre les murs les vides sanitaires les plafonds les greniers ou les garages Tout l chappe...

Page 39: ...e c t 95 22 3 4 po Recouvrement de conduit standard min 30 1 2 po max 49 1 2 po Pi ce de prolongement Z1C 00OK min 44 po max 77 po 6 po 10 po 5 1 8 po 4 1 4 po 36 po 26 1 16 po 42 po 26 1 16 po 48 po...

Page 40: ...rot g par un disjoncteur de 15 ou 20 amp res ou un fusible temporis Le c blage doit tre 2 fils avec terre Veuillez galement vous r f rer au sch ma lectrique tiquet sur le produit Le c blage lectrique...

Page 41: ...int rieur du corps de la hotte et fixez le l aide de 2 vis M4 8 de la quincaillerie interne du ventilateur 5 Connectez le connecteur molex 9 broches du moteur interne au connecteur molex 9 broches du...

Page 42: ...distance travers l orifice d fon able du c blage du ventilateur distance Fixez par 4 vis M4 8 5 Connectez le connecteur m le 6 broches du c blage du ventilateur distance au connecteur femelle 6 broche...

Page 43: ...6 po de la ligne m diane sur la ligne C FIG C 6 Placez le support de plafond du couvercle du conduit sur le plafond et marquez le diam tre int rieur du support de plafond Coupez le diam tre int rieur...

Page 44: ...ral La l vre l arri re du corps de la hotte reposera entre le mur et la l vre sup rieure du support mural Fixez le corps de la hotte en place l aide de 2 vis M4 38 dans la partie inf rieure de l int r...

Page 45: ...utes apr s son activation Lorsque vous appuyez une fois sur un point clignote dans la partie inf rieure droite de l afficheur pour vous confirmer que la fonction a t activ e La hotte s teint compl te...

Page 46: ...ll s r initialisez l indicateur de nettoyage des filtres avec la hotte hors tension Lorsque la hotte est teinte appuyez environ 5 sec ondes sur la touche jusqu ce que l ic ne disparaisse La fonction d...

Page 47: ...pr s le nettoyage utilisez un produit de polissage nettoyant pour acier inoxydable non abrasif pour polir et polir le lustre et le grain de l acier inoxydable Frottez toujours l g rement avec un chiff...

Page 48: ...ante tomberait en panne veuillez contacter Zephyr pour commander des pi ces de rechange Consultez la page Liste des pi ces et accessoires pour les num ros de pi ces et les coordonn es Retrait de LED F...

Page 49: ...IR BLANC CORPS NOIR BLANC NOIR BLANC BLEU ROUGE JAUNE PC de commande LED LED LED LED pour 48 po seulement MOTEUR CORPS GRIS NOIR NOIR BLANC BLANC NOIR L L B W SW BLANC Amp rage maximal Sch ma de c bla...

Page 50: ...ORPS NOIR BLANC NOIR BLANC BLEU ROUGE JAUNE PC de commande LED LED LED LED pour 48 po seulement NOIR BLANC BLANC NOIR L L B W SW BLANC Amp rage maximal Sch ma de c blage du ventilateur interne Remarqu...

Page 51: ...ct s au bo tier du tableau de commande Le syst me de protection thermique d tecte si le ventilateur est trop chaud pour fonctionner et arr te le ventilateur Le ventilateur fonctionnera correctement ap...

Page 52: ...le ventilateur externe La hotte peut tre suspendue trop haut la table de cuisson Ajustez la distance entre la table de cuisson et le bas de la hotte dans une plage de 24 po et 36 po Le vent provenant...

Page 53: ...i ces de rechange Filtre chicane chacun 50210036 Ampoule LED 4W P12010008 LumiLight LED 6W Z0B0052 Accessoires optionnels Rallonge de couvercle de conduit Z1C 00TP Ventilateur interne simple CBI 290C...

Page 54: ...26 Okeanito Guide d utilisation d entretien et d installation MUR DESIGNER OKEANITO Remarques...

Page 55: ...s de main d uvre associ s la pr sente garantie Restrictions de la garantie NOTRE OBLIGATION DE R PARER OU DE REMPLACER NOTRE GR LE PRODUIT CONSTITUE VOTRE SEUL ET UNIQUE RECOURS SOUS LA PR SENTE GARAN...

Page 56: ...it au www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Cet enregistrement rapide est utile bien des gards C EST IMPORTANT Il assure la couvertu...

Reviews: