background image

27

Okeanito Use, Care, and Installation Guide

ZEPHYRONLINE.COM

Limited Warranty

JAN21.0501

Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein 

as  “you”  or  “your”)  of  Zephyr  products  (the  “Products”)  that  such  Products  will  be  free  from  defects  in  materials  or 

workmanship as follows: 

Three Year Limited Warranty for Parts: 

For three years from the date of your original purchase of the Products, we will 

provide,  free  of  charge,  Products  or  parts  (including  LED  light  bulbs,  if  applicable)  to  replace  those  that  failed  due  to 

manufacturing defects subject to the exclusions and limitations below. We may choose, in our sole discretion, to repair or 

replace parts before we elect to replace the Products.

One Year Limited Warranty for Labor: 

For one year from the date of your original purchase of the Products, we will 

provide, free of charge, the labor cost associated with repairing the Products or parts to replace those that failed due to 

manufacturing defects subject to the exclusions and limitations below. After the first year from the date of your original 

purchase, you are responsible for all labor costs associated with this warranty.

Warranty Exclusions: 

This warranty covers only repair or replacement, at our option, of defective Products or parts and 

does not cover any other costs related to the Products including but not limited to: (a) normal maintenance and service 

required for the Products and consumable parts such as fluorescent, incandescent or halogen light bulbs, mesh and char-

coal filters and fuses; (b) any Products or parts which have been subject to freight damage, misuse, negligence, accident, 

faulty installation or installation contrary to recommended installation instructions, improper maintenance or repair (other 

than by us); (c) commercial or government use of the Products or use otherwise inconsistent with its intended purpose; (d) 

natural wear of the finish of the Products or wear caused by improper maintenance, use of corrosive and abrasive cleaning 

products, pads, and oven cleaner products; (e) chips, dents or cracks caused by abuse or misuse of the Products; (f) service 

trips to your home to teach you how to use the Products; (g) damage to the Products caused by accident, fire, floods, acts 

of God; or (h) Custom installations or alterations that impact serviceability of the Products. If you are outside our service 

area, additional charges may apply for shipping costs for warranty repair at our designated service locations and for the 

travel cost to have a service technician come to your home to repair, remove or reinstall the Products. After the first year 

from the date of your original purchase, you are also responsible for all labor costs associated with this warranty. All Products 

must be installed by a qualified professional installer to be eligible for warranty repairs or service.

Limitations of Warranty. OUR OBLIGATION TO REPAIR OR REPLACE, AT OUR OPTION, SHALL BE YOUR SOLE 

AND  EXCLUSIVE  REMEDY  UNDER  THIS  WARRANTY.  WE  SHALL  NOT  BE  LIABLE  FOR  INCIDENTAL, 

CONSEQUENTIAL  OR  SPECIAL  DAMAGES  ARISING  OUT  OF  OR  IN  CONNECTION  WITH  THE  USE  OR 

PERFORMANCE  OF  THE  PRODUCTS.  THE  EXPRESS  WARRANTIES  IN  THE  PRECEDING  SECTION  ARE 

EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. WE HEREBY DISCLAIM AND EXCLUDE ALL 

OTHER  EXPRESS  WARRANTIES  FOR  THE  PRODUCTS,  AND  DISCLAIM  AND  EXCLUDE  ALL  WARRANTIES 

IMPLIED  BY  LAW,  INCLUDING  THOSE  OF  MERCHANTABILITY  AND  FITNESS  FOR A  PARTICULAR  PURPOSE

.

Some states or provinces do not allow limitations on the duration of an implied warranty or the exclusion or limitation of 

incidental  or  consequential  damages,  so  the  above  limitations  or  exclusions  may  not  apply  to  you.  To  the  extent  that 

applicable law prohibits the exclusion of implied warranties, the duration of any applicable implied warranty is limited to the

same three-year and one-year periods described above if permitted by applicable law. Any oral or written description of the 

Products is for the sole purpose of identifying the Products and shall not be construed as an express warranty. Prior to 

using, implementing or permitting use of the Products, you shall determine the suitability of the Products for the intended 

use, and you shall assume all risk and liability whatsoever in connection with such determination. We reserve the right to 

use functionally equivalent refurbished or reconditioned parts or Products as warranty replacements or as part of warranty 

service. This warranty is not transferable from the original purchaser and only applies to the consumer residence where the 

Product was originally installed located in the United States and Canada. This warranty is not extended to resellers. 

To Obtain Service Under Limited Warranty: 

To qualify for warranty service, you must: (a) notify us at the address or 

telephone number stated below within 60 days of the discovery of the defect; (b) give the model number and serial number; 

and (c) describe the nature of any defect in the Product or part. At the time of the request for warranty service, you must 

present evidence of your proof of purchase and proof of the original purchase date. If we determine that the warranty 

exclusions listed above apply or if you fail to provide the necessary documentation to obtain service, you will be responsible 

for all shipping, travel, labor and other costs related to the services.  This warranty is not extended or restarted upon warranty

repair or replacements.
Please check our website for any additional Product information, 

www.zephyronline.com

Zephyr, 2277 Harbor Bay Parkway, Alameda, CA 94502

 

 

TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS 

United States Customers please call: 1-888-880-8368 or contact us at: zephyronline.com/contact

Canada Customers please call: 1-800-361-0799 or Email: [email protected]

Limited Warranty

Summary of Contents for Okeanito COK-E36CBGX

Page 1: ...WWW ZEPHYRONLINE COM DEC21 0101 Okeanito COK E36CSX COK E42CSX COK E48CSX COK E36CBGX COK E42CBGX COK E48CBGX EN Use Care and Installation Guide FR Guide d utilisation d entretien et d installation...

Page 2: ...2 Okeanito Use Care and Installation Guide OKEANITO WALL DESIGNER...

Page 3: ...heet 8 Mounting Height Clearance Ducting 9 Ducting Options 10 Hood Specifications 11 Electrical Supply 12 Cable Lock 12 Internal Blower Preparation 13 Remote Blower Preparation 14 Mounting the Range H...

Page 4: ...ocked securely fasten a prominent warning device such as a tag to the service panel General Safety WARNING Warning means that failure to heed this safety statement may result in extensive product dama...

Page 5: ...ithin walls ceilings attics crawl spaces or garages WARNING WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring must...

Page 6: ...National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and...

Page 7: ...4 Swivel LumiLight LED 6W pre installed 48 model 2 4W mood LED bulbs 2 Telescopic duct covers 1 Duct cover ceiling bracket 1 Utensil rail 1 Wall mount hanging bracket 1 8 round starting collar with da...

Page 8: ...t Ft Ft 6 7 8 10 Round roof cap 30 Ft x Ft Subtotal column2 Subtotal column1 Total ductwork Maximum Duct Length For satisfactory air movement the totalductlengthshould not exceed 150 equivalent feet 6...

Page 9: ...hould be no higher than 36 It is important to install the insert at the proper mounting height Inserts mounted too low could result in heat damage and fire hazard while inserts mounted too high will b...

Page 10: ...al screws and tape all joints w certified Silver Tape or Duct Tape Fire Hazard NEVER exhaust air or terminate ductwork into spaces between walls crawl spaces ceilings attics or garages All exhaust mus...

Page 11: ...Specifications Front View Bottom View Top View Side View 95 22 3 4 Standard Duct Cover min 30 1 2 max 49 1 2 Z1C 00OK Extension min 44 max 77 6 10 5 1 8 4 1 4 36 26 1 16 42 26 1 16 48 41 21 36 5 42 8...

Page 12: ...this appliance Follow national electrical codes or prevailing local codes and ordinances This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch...

Page 13: ...ening 3 Position capacitor box inside hood body and secure by 2 M4 8 screws from internal blower hardware 5 Connect 9 pin molex connector from internal motor to 9 pin molex connector from capacitor ca...

Page 14: ...k and remote blower wiring harness through the remote blower wiring knockout Attach by 4 M4 8 screws 5 Connect 6 pin male connector from remote blower wiring to 6 pin female connector on control board...

Page 15: ...nting spread 8 11 16 from center line on line C FIG C 6 Place duct cover ceiling bracket onto ceiling and mark inside diameter of ceiling bracket Cut inside diameter of ceiling bracket to fit the 6 or...

Page 16: ...k of the hood body will rest between the wall and the top lip of the wall bracket Secure hood body in place by 2 M4 38 screws though bottom section of interior of hood body FIG E 12 Place telescopic d...

Page 17: ...s on The blower will completely shut down after 5 minutes 4 Lights Low Medium High Off Switch lights on to low by pressing once press a second time for medium press a third time for high and press aga...

Page 18: ...s of use Reset the filter clean reminder timer after filters are cleaned and re installed With hood off press and hold for approxi mately 5 seconds until on display disappears The filter clean reminde...

Page 19: ...inless steel polish cleaners to polish and buff out the stainless luster and grain Always scrub lightly with clean cotton cloth or micro fiber cloth and buff in the direction of the stainless steel gr...

Page 20: ...LED In the unlikely event that your swivel LumiLight LED fails please contact Zephyr to order replacement parts See the list of parts and accessories page for part numbers and contact information LED...

Page 21: ...MPS CBI 290C 0 8 CBI 390A 2 1 CBI 600A 2 6 REMARKS CONDENSER 3 uF 250V AC120V 60Hz CBI 290C CONDENSER 25uF 250V AC120V 60Hz CBI 390A CBI 600A WHITE YELLOW RED BLUE GREEN BLACK WHITE BODY BLACK WHITE B...

Page 22: ...W RED BLUE GREEN BLACK WHITE BODY BLACK WHITE BLACK WHITE BLUE RED YELLOW Control PC LED LED LED LED for 48 only BLACK WHITE WHITE BLACK L L B W SW WHITE CBE 1000 6 2 PBN 1000A 5 1 REMARKS CONDENSER 1...

Page 23: ...m detects if the blower is too hot to operate and shuts the blower down The blower will function properly after the thermally protected system cool down Damaged capacitor Change the capacitor Blower m...

Page 24: ...he cooktop and the bottom of the hood within 24 and 36 range The wind from the opened windows or opened doors in the surrounding area are affecting the ventilation of the hood Close all the windows an...

Page 25: ...ber Replacement Parts Baffle Filter each 50210036 LED Bulb 4W P12010008 Swivel LumiLight LED 6W Z0B0052 Optional Accessories Duct Cover Extension Z1C 00OK Single Internal Blower CBI 290C CBI 600A Exte...

Page 26: ...26 Okeanito Use Care and Installation Guide OKEANITO WALL DESIGNER Notes...

Page 27: ...to be eligible for warranty repairs or service Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LI...

Page 28: ...a moment to register your new Zephyr product at www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Prompt registration helps in more ways than on...

Page 29: ...WWW ZEPHYRONLINE COM DEC21 0101 Okeanito COK E36CSX COK E42CSX COK E48CSX COK E36CBGX COK E42CBGX COK E48CBGX EN Use Care and Installation Guide FR Guide d utilisation d entretien et d installation...

Page 30: ...2 Okeanito Guide d utilisation d entretien et d installation MUR DESIGNER OKEANITO...

Page 31: ...conduit d a ration 8 Hauteur de montage d gagement et gaine 9 Options de conduits 10 Sp cifications de la hotte 11 Fourniture lectrique 12 Raccord de c ble 12 Pr paration du ventilateur interne 13 Pr...

Page 32: ...Avant l entretien ou le nettoyage de l unit coupez l alimentation au panneau de service et verrouillez les moyens de d connexion de service pour viter toute mise sous tension accidentelle Lorsque le m...

Page 33: ...normes applicables y compris la construction r sistant au feu b Une quantit d air suffisante est n cessaire pour une combustion et une vacuation correctes des gaz par le conduit de fum e chemin e de...

Page 34: ...d quate et conforme au National Electrical Code ANSI NFPA 70 derni re dition ou aux normes CSA C22 1 94 Code canadien de l lectricit partie 1 et C22 2 No 0 M91 derni re dition et tous les codes et ord...

Page 35: ...t Z1C 00OK Pi ces fournies Quantit Partie 1 Hotte 1 Filtres chicanes mod les 36 po et 42 po 2 Filtres chicanes mod le 48 po 2 LumiLight LED pivotante 6W pr install mod les 36 po et 42 po 4 LumiLight L...

Page 36: ...bre utilis rect droit circ droit rect coude 90 rect coude 45 rect coude plat 90 circ coude 90 coude 45 Sous total colonne 1 Longueur maximale du conduit d a ration Pour un mouvement d air convenable l...

Page 37: ...installer la l insert la bonne hauteur de 24 po min 36 po max min C max D Standard Extension Hauteur de la hotte Duct Cover Duct Cover minimum A 30 1 2 po 44 po maximum B 49 1 2 po 77 po Hauteur du p...

Page 38: ...argent ou du ruban adh sif Risque d incendie NE JAMAIS vacuer l air ni terminer de conduits dans des espaces entre les murs les vides sanitaires les plafonds les greniers ou les garages Tout l chappe...

Page 39: ...e c t 95 22 3 4 po Recouvrement de conduit standard min 30 1 2 po max 49 1 2 po Pi ce de prolongement Z1C 00OK min 44 po max 77 po 6 po 10 po 5 1 8 po 4 1 4 po 36 po 26 1 16 po 42 po 26 1 16 po 48 po...

Page 40: ...rot g par un disjoncteur de 15 ou 20 amp res ou un fusible temporis Le c blage doit tre 2 fils avec terre Veuillez galement vous r f rer au sch ma lectrique tiquet sur le produit Le c blage lectrique...

Page 41: ...int rieur du corps de la hotte et fixez le l aide de 2 vis M4 8 de la quincaillerie interne du ventilateur 5 Connectez le connecteur molex 9 broches du moteur interne au connecteur molex 9 broches du...

Page 42: ...distance travers l orifice d fon able du c blage du ventilateur distance Fixez par 4 vis M4 8 5 Connectez le connecteur m le 6 broches du c blage du ventilateur distance au connecteur femelle 6 broche...

Page 43: ...6 po de la ligne m diane sur la ligne C FIG C 6 Placez le support de plafond du couvercle du conduit sur le plafond et marquez le diam tre int rieur du support de plafond Coupez le diam tre int rieur...

Page 44: ...ral La l vre l arri re du corps de la hotte reposera entre le mur et la l vre sup rieure du support mural Fixez le corps de la hotte en place l aide de 2 vis M4 38 dans la partie inf rieure de l int r...

Page 45: ...utes apr s son activation Lorsque vous appuyez une fois sur un point clignote dans la partie inf rieure droite de l afficheur pour vous confirmer que la fonction a t activ e La hotte s teint compl te...

Page 46: ...ll s r initialisez l indicateur de nettoyage des filtres avec la hotte hors tension Lorsque la hotte est teinte appuyez environ 5 sec ondes sur la touche jusqu ce que l ic ne disparaisse La fonction d...

Page 47: ...pr s le nettoyage utilisez un produit de polissage nettoyant pour acier inoxydable non abrasif pour polir et polir le lustre et le grain de l acier inoxydable Frottez toujours l g rement avec un chiff...

Page 48: ...ante tomberait en panne veuillez contacter Zephyr pour commander des pi ces de rechange Consultez la page Liste des pi ces et accessoires pour les num ros de pi ces et les coordonn es Retrait de LED F...

Page 49: ...IR BLANC CORPS NOIR BLANC NOIR BLANC BLEU ROUGE JAUNE PC de commande LED LED LED LED pour 48 po seulement MOTEUR CORPS GRIS NOIR NOIR BLANC BLANC NOIR L L B W SW BLANC Amp rage maximal Sch ma de c bla...

Page 50: ...ORPS NOIR BLANC NOIR BLANC BLEU ROUGE JAUNE PC de commande LED LED LED LED pour 48 po seulement NOIR BLANC BLANC NOIR L L B W SW BLANC Amp rage maximal Sch ma de c blage du ventilateur interne Remarqu...

Page 51: ...ct s au bo tier du tableau de commande Le syst me de protection thermique d tecte si le ventilateur est trop chaud pour fonctionner et arr te le ventilateur Le ventilateur fonctionnera correctement ap...

Page 52: ...le ventilateur externe La hotte peut tre suspendue trop haut la table de cuisson Ajustez la distance entre la table de cuisson et le bas de la hotte dans une plage de 24 po et 36 po Le vent provenant...

Page 53: ...i ces de rechange Filtre chicane chacun 50210036 Ampoule LED 4W P12010008 LumiLight LED 6W Z0B0052 Accessoires optionnels Rallonge de couvercle de conduit Z1C 00TP Ventilateur interne simple CBI 290C...

Page 54: ...26 Okeanito Guide d utilisation d entretien et d installation MUR DESIGNER OKEANITO Remarques...

Page 55: ...s de main d uvre associ s la pr sente garantie Restrictions de la garantie NOTRE OBLIGATION DE R PARER OU DE REMPLACER NOTRE GR LE PRODUIT CONSTITUE VOTRE SEUL ET UNIQUE RECOURS SOUS LA PR SENTE GARAN...

Page 56: ...it au www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Cet enregistrement rapide est utile bien des gards C EST IMPORTANT Il assure la couvertu...

Reviews: