background image

16

www.zephyronline.com

Fan Curve Diagrams

A

irflow Control Technology (ACT)

Some local codes limit the maximum amount of CFM a range hood can move.  ACT allows you to 

control the maximum blower CFM of hoods with of select Zephyr Ventilation range hoods without the 

need for expensive make up air kits.  ACT enables the installer to easily set the maximum blower speed 

to one of two most commonly specified CFM levels; 390 or 290 CFM. The usage of ACT may not be 

necessary for your installation. Please check your local codes for CFM restrictions.  

 

 

By default the maximum blower CFM is set to 600.

To verify if your installer enabled ACT; With hood off, press and hold the power button for three seconds. 

If 5 LEDs illuminate = defualt max. CFM, if 4 LEDs illuminate = max. 390 CFM, and if 3 LEDs illuminate 

= max. 290 CFM. When ACT is enabled, the number of blower speeds will be reduced. 390 CFM = max. 

3 speeds and 290 CFM = max. 2 speeds. There should also be a foil label located inside the hood body 

near the wiring diagram that indicates the blower CFM. 

Summary of Contents for Luce Island ZLC-M90AS

Page 1: ...Use Care and Installation Guide Model number Serial Number www zephyronline com FEB16 0201 Zephyr Ventilation LLC Air ow Control Technology TM C Luce Island ZLC M90AS ZLC E42AS...

Page 2: ...www zephyronline com...

Page 3: ...ng Options 7 RRG 6SHFL FDWLRQV 8 Mounting the Hood 9 10 Ductless Recirculating 11 FEATURES CONTROLS ICON Touch Controls 12 13 MAINTENANCE Hood and Filter Cleaning 14 TROUBLESHOOTING 15 FAN CURVE DIAGR...

Page 4: ...are and utensils appropriate for the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING D 6027 5 0 6 ZLWK...

Page 5: ...SI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances I FRGHV SHUPLW DQG D VHSDUDWH JURXQG ZLUH LV XV...

Page 6: ...TS NOT SUPPLIED Ducting conduit and all installation tools Cable connector if required by local codes Duct cover extension accessory Recirculating kit accessory 2 Top Duct Covers 1 Top Support Frame 2...

Page 7: ...lumn 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 6 roundto 3 1 4 x 10 rect transition 1 Ft x Ft 6 r...

Page 8: ...IRUPDQFH DQG HI FLHQF If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any differences D...

Page 9: ...ted to the outside unless using the recirculating option Use single wall rigid metal ductwork only DVWHQ DOO FRQQHFWLRQV ZLWK VKHHW PHWDO VFUHZV DQG WDSH DOO MRLQWV Z FHUWL HG 6LOYHU 7DSH RU XFW 7DSH...

Page 10: ...DE TOP of HOOD TOP SUPPORT FRAME top view FRONT 11 35 7 16 41 7 8 9 7 16 12 3 8 25 9 16 10 5 8 STANDARD min ducted 28 min recirc 32 1 2 max 46 1 2 Z1C 00LC min ducted 47 min recirc 51 max 80 6 2 1 2 1...

Page 11: ...rd front on the top support frame faces the IURQW RI WKH KRRG ZKHUH WKH FRQWUROV ZLOO EH ORFDWHG 7KH NH KROHV RQ WKH WRS VXSSRUW IUDPH VKRXOG cover the wood screws previously installed in the ceiling...

Page 12: ...ode you must install the air diverter plate to the Top Support Frame prior to assembling the duct covers Turn to page 11 for more details 6HFXUH 7RS XFW RYHUV WR 7RS 6XSSRUW UDPH E XVLQJ VFUHZV VFUHZV...

Page 13: ...WHU SODWH Hood Models Part No Filters in pkg ZLC M90AS ZRC 00LC 1 ZLC E42AS ZRC 00LC 1 1 Purchase recirculating kit per the part number above 2 Secure air diverter plate to top support frame Open side...

Page 14: ...tion is enabled will turn the hood off and cancel the Delay Off Function ACT Verification Airflow Control Technology ACT allows the installer to set the maximum fan CFM to align with local codes and r...

Page 15: ...D indicators will illuminate for three seconds confirming the Charcoal Filter Replace Reminder is enabled To disable Charcoal Filter Replacement Reminder With hood off hold button and button simultane...

Page 16: ...ith clean cotton cloth and with the grain Do not use any product containing chlorine bleach Do not use orange cleaners Aluminum Mesh Filters 7KH DOXPLQXP PHVK OWHUV LQVWDOOHG E WKH IDFWRU DUH LQWHQGHG...

Page 17: ...it is vibrating 1 The blower is not secured in place 1 Tighten the blower in place 2 Damaged blower wheel 2 Replace the blower 3 The hood is not secured in place 3 Check the installation of the hood T...

Page 18: ...390 or 290 CFM The usage of ACT may not be necessary for your installation Please check your local codes for CFM restrictions By default the maximum blower CFM is set to 600 To verify if your installe...

Page 19: ...17 Fan Curve Diagrams...

Page 20: ...Y PROTECTED Fan 300W Lamp LED 3Wx4 Total 336W Voltage 120V 60Hz 3 0A Model ZLC E42AS Power consumption ZLC M90AS Acrylic Max 24W 3RZHU FRQVXPSWLRQ VKRZQ IRU GHIDXOW 0 EORZHU FRQ JXUDWLRQ ACT 390 CFM F...

Page 21: ...OXPLQXP 0HVK LOWHU HDFK Optional Accessories Recirculating Kit ZRC 00LC 5HSODFHPHQW KDUFRDO LOWHU HDFK Extension Duct Cover Z1C 00LC To order parts visit us online at http store zephyronline com or c...

Page 22: ...oducts After the first year from the date of your original purchase you are also responsible for all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLA...

Page 23: ...21...

Page 24: ...our new range hood at www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Prompt registration helps in more ways than one IT S IMPORTANT Ensures w...

Page 25: ...n d entretien et d installation Num ro de mod le _________________ Num ro de s rie _________________ FEB16 0201 Zephyr Ventilation LLC Air ow Control Technology TM C Luce Island ZLU M90AS ZLU E42AS ww...

Page 26: ...www zephyronline com...

Page 27: ...n pour le conduit 7 6SpFL FDWLRQV GH OD KRWWH 8 Montage de la hotte 9 10 Reprise d air sans conduit 11 COMMANDES ICON Commandes 12 13 ENTRETIEN 1HWWR DJH GHV OWUHV HW GH OD KRWWH 14 D PANNAGE 15 TABLE...

Page 28: ...pas la hotte sans surveillance lorsque vous cuisinez h Utilisez toujours une batterie de cuisine et des ustensiles convenant au type et la quantit de nourriture que vous pr parez AVERTISSEMENT POUR R...

Page 29: ...u elle respecte le Code national de l lectricit la plus r cente dition du ANSI NFPA 70 ou des normes du CSA C22 1 94 le Code canadien de l lectricit section 1 la plus r cente dition du code C22 2 No 0...

Page 30: ...TENU DE LA TROUSSE DE QUINCAILLERIE 2 Pi ces de recouvrement sup rieures pour le conduit 1 Cadre de fixation sup rieur 2 Pi ces de recouvrement inf rieures pour le conduit 1 Cadre de fixation inf rieu...

Page 31: ...rect coude plat 90 circ coude 90 coude 45 Sous total colonne 1 Longueur maximale du conduit d a ration Pour un mouvement d air convenable la longueur totale d un conduit d a ration ne devrait pas comp...

Page 32: ...consultez les exigences de hauteur d espace libre requise par le fabricant de la cuisini re ainsi que la hauteur recommand e de montage de la hotte au dessus de la surface de cuisson Informez vous to...

Page 33: ...air ne soit utilis e N utilisez que des conduits en m tal pour cloison simple Fixez toutes les pi ces du conduit avec des vis t le et isolez tous les joints avec du ruban adh sif en toile ou GX UXEDQ...

Page 34: ...1 35 7 16 41 7 8 9 7 16 12 3 8 25 9 16 10 5 8 STANDARD min ducted 28 min recirc 32 1 2 max 46 1 2 Z1C 00LC min ducted 47 min recirc 51 max 80 6 2 1 2 1 1 4 3 7 16 C L C L 7 9 16 6 3 4 8 1 8 7 13 16 DE...

Page 35: ...ODIRQG DLWHV JOLVVHU OH FDGUH GH DWLRQ YHUV OD SDUWLH pWURLWH GHV HQFRFKHV HQ WURX GH VHUUXUH SRXU OH HU HQ SODFH QVWDOOH OHV GHX GHUQLqUHV YLV j ERLV 0 DYHF GHV URQGHOOHV GDQV OHV GHX FRLQV GX FDGUH...

Page 36: ...X FDGUH GH DWLRQ VXSpULHXU DYDQW G DVVHPEOHU OHV SLqFHV GH recouvrement de conduit Consultez la page 11 pour plus de d tails L H OHV SLqFHV GH UHFRXYUHPHQWV VXSpULHXUHV DX FDGUH GH DWLRQ VXSpULHXUH j...

Page 37: ...ZRC 00LC 1 ZLC E42AS ZRC 00LC 1 1 Procurez vous l ensemble de reprise d air en utilisant le num ro de pi ce ci dessus L H OD SODTXH GX Gp HFWHXU G DLU DX FDGUH GH DWLRQ VXSpULHXU HV F WpV RXYHUWV GH...

Page 38: ...tilisation pour teindre la hotte et annuler la fonction d arr t retardement V rification de la TCDA La technologie de contr le du d bit d air permet l installeur d ajuster la quantit maximale d vacuat...

Page 39: ...us les indicateurs DEL s illuminent pendant trois secondes confirmant l activation du rappel de remplacement des filtres charbon Pour d sactiver le rappel de remplacement des filtres charbon Lorsque l...

Page 40: ...ton propre et dans le sens du grain 1 XWLOLVH SDV GH SURGXLWV j EODQFKLU DX FKORUH RX G DJHQWV QHWWR DQWV RUDQJH LOWUH j GH HFWXHU HV OWUHV j WDPLV HQ DOXPLQLXP LQVWDOOpV SDU OH IDEULFDQW RQW SRXU IRQ...

Page 41: ...e DEL est d fectueuse 1 Remplacez l ampoule DEL 2 Le c ble de l ampoule DEL est d branch du tableau de commande 9pUL H OD FRQQH LRQ GHV FkEOHV GH O DPSRXOH du tableau de commande 3 Le connecteur de l...

Page 42: ...na tre les restrictions en mati re de pieds cubes par minute Par d faut le nombre maximal de pi3 min du ventilateur est de 600 Pour v rifier si votre installateur a activ la ACT appuyez sur la touche...

Page 43: ...17 Tableau De Rendement Du Ventilateur...

Page 44: ...Acrylic Max 24W SCH MADECIRCUITS PROT G THERMIQUEMENT BLANC BLANC ROUGE JAUNE ROUGE JAUNE JAUNE GRIS BRUN BRUN BLEU BLEU NOIR NOIR BLANC VERT CORPS CORPS VERT NOIR BLANC 6FKpPD H kEODJH RQVRPPDWLRQ PR...

Page 45: ...ptionnels Ensemble de reprise d air ZRC 00LC Filtre charbon de remplacement chaque Z0F C092 Ensemble de prolongement de recouvrement de conduit Z1C 00LC Pour commander des pi ces visitez nous en ligne...

Page 46: ...stall Un an apr s la date d achat originale du Produit vous tes galement responsable de tous les frais de main d uvre associ s la pr sente garantie Restrictions de la garantie NOTRE OBLIGATION DE R PA...

Page 47: ...21...

Page 48: ...ration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Cet enregistrement rapide est utile bien des gards C EST IMPORTANT Il assure la couverture de votre garantie si vous avez...

Reviews: