14
15.
Hang hood on hooks with the 2 brackets.
WARNING
Excessive Weight Hazard - Use two or more people
to move and install range hood. Failure to do so can
result in back or other injury.
16.
Level the appliance, using a carpenters level
across bottom of hood with levelling screws in
mounting brackets.
Note1:
Levelling screws are supplied in the
hardware packet and must be screwed on top of the
bracket.
Note2:
Further adjustments may be possible
sliding the brackets, loosen the screws the fix them
to the body of the hood and retighten when hood is
in place as desired.
17.
Open the front door, remove the grease filter (see
paragraph "Maintenance - Front Door" and
"Maintenance - Grease filter") and secure hood with
2 screws on bottom.
Hooks
CL
Levelling
screws
Bracket
Bracket
Lower
fastener
locations
Lower
fastener
screws
Junction
Box
18. Ducting version - vertical discharge ONLY:
Install the transition on top of the hood with 2
screws.
Connect ducting to transition. Seal with duct tape.
Do not use duct smaller than the transition.
Ductless (recirculating) version ONLY:
Install the deflector (available as an extra kit). on top
of the hood.
Ducting
version
Vertical
discharge
19. Electrical connection
WARNING
Electrical Shock Hazard
Warning: Turn off power circuit at the service panel
before wiring this unit.
120 VAC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN ELECTRICAL
JUNCTION BOX WITH 3 WIRES, ONE OF WHICH
(GREEN/YELLOW) SERVES TO GROUND THE
APPLIANCE. TO PROTECT YOU AGAINST ELECTRIC
SHOCK, THE GREEN AND YELLOW WIRE MUST BE
CONNECTED TO THE GROUNDING WIRE IN YOUR
HOME ELECTRICAL SYSTEM, AND IT MUST UNDER
NO CIRCUMSTANCES BE CUT OR REMOVED.
Failure to do so can result in death or electrical
shock.
On top of the hood on the right side is found the
Junction box, remove the knockout and the Junction box
cover and install the conduit connector (cULUS listed)
in junction box cover.
Run 3 wires; black, white and green ,according to the
National Electrical Code and local codes and
ordinances, in 1/2" conduit from service panel to
junction box.