Installation

1.

If possible, disconnect and move freestanding or
slide-in range from cabinet opening to provide
easier access to rear wall. Otherwise put a thick,
protective covering over countertop, cooktop or
range to protect from damage or dirt. Select a flat
surface for assembling the unit. Cover that surface
with a protective covering and place all canopy hood
parts and hardware in it.

2.

Determine and mark the centerline on the wall
where the canopy hood will be installed.

3.

Select a mounting height comfortable for the user
and mark on wall behind cooktop.

4.

Tape template, matching center-line and hood
bottom as shown in  Figure  below.

5.

Mark center of two top fastener location and two
lower fastener location.

Ducting Version towards the rear side ONLY
(Horizontal discharge):
Mark the cut out to be done for duct passage.

Remove the template.

top fasteners

locations

CL

centerline

mounting

height

reference

fasteners

locations

Hooks

Duct

passage

(Ducting

Version

horizontal

discharge)

6.

Mark wall with horizontal line 1" above highest and
1" below lowest fastener location.

7.

Find studs behind drywall by tapping wall or using a
stud finder. Mark the center of the studs with a
vertical line to the right and left of the marked
fastener location.

8. Note

: all fastener locations must span the studs

otherwise proceed as follows:
Cutout drywall along marked lines. Install each
necessary between studs firmly flush with already
existing stud front. Make sure all mounting screws
will anchor to added studs.  Replace drywall and
refinish.

C

L

Wood cross

support secured

to framing and

located behind

drywall

Framing behind drywall

9.

Determine and make all necessary cuts in the wall
for the vent system. Install the vent system before
the canopy hood. See „Venting methods“ and
„Dimensions and clearance“  paragraphs.

Note - for Ductless - recirculating - installations:

Vent system is not required.

Inst

allation

Summary of Contents for Elica Om

Page 1: ...ber Num rodes rie _____________________________________ N merodeserie DateofPurchase Dated achat _____________________________________ Fechadecompra SalesDealer D taillant ____________________________...

Page 2: ...eave these Instructions with this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at service panel and lock out panel before wiring...

Page 3: ...pplied 6 Dimensions and clearances 7 Installation Instructions 8 Venting methods 8 Preparation 8 Installation Ductwork Calculation Sheet 9 Installation Discharge direction 10 Installation 12 Electrica...

Page 4: ...Use This Hood With Any External Solid State Speed Control Device WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking a...

Page 5: ...local codes and ordinances A U L or C S A listed conduit connector must be provided at each end of the power supply conduit at the range hood and at the junction box Copies of the standards listed may...

Page 6: ...Installation guide Template Screw 3 5x9 5 x 2 to fix the transition on top of the hood Vertical discharge Screw 5x45 x 8 to fix the hood and to fix the transition on the rear wall Horizontal discharg...

Page 7: ...e 32 28 5 8 7 1 16 rear wall 13 3 4 Conduit vertical horizontal discharge and Ducting area passage Vertical discharge only Duct bends are not considered 1 1 4 13 3 4 3 3 4 24 5 16 min 47 14 16 max 65...

Page 8: ...Pipe Minimum Duct Size Ducting version Horizontal discharge 3 1 4 x 10 PREPARATION Do not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must b...

Page 9: ...wall cap with damper 6 Round roof cap 6 Round to 3 1 4 x 10 rect transition 6 Round to 3 1 4 x 10 rect transition 90 elbow 7 8 round 90 elbow 7 8 round 45 elbow 7 8 Round wall cap with damper 7 8 Rou...

Page 10: ...from electronic box press on both side locks to release and remove wiring from blocks located on top side of the electronic box from Blower unit Side locks Blower wiring Wiring block Slide from a sid...

Page 11: ...the top side Vertical discharge firmly tighten the 4 fixing screws WARNING When performing this step check that wirings run in a proper way DO NOT DAMAGE OR PULL WIRINGS Vertical discharge Horizontal...

Page 12: ...te top fasteners locations C L centerline mounting height reference fasteners locations Hooks Duct passage Ducting Version horizontal discharge 6 Mark wall with horizontal line 1 above highest and 1 b...

Page 13: ...must be enough power supply cable from the fused disconnect or circuit breaker box to make the connection in the hood s Junction box es Use caulking to seal all openings Further adjustment do conduit...

Page 14: ...transition Seal with duct tape Do not use duct smaller than the transition Ductless recirculating version ONLY Install the deflector available as an extra kit on top of the hood Ducting version Vertic...

Page 15: ...r available as an extra kit 22 Install metal filter and close the front door see paragraph Maintenance Front Door and Maintenance Grease filter 23 Check all light bulbs to make sure they are secure in...

Page 16: ...Description of the hood 1 Control panel 2 Grease filter 3 Grease filter release handle 4 Halogen lamp position and nr of lamps may vary 5 Front door 6 Air outlet on top and on the rear side 1 3 2 4 4...

Page 17: ...2 will flash then only key 1 to indicate deactivation Low speed selection touch sensor key suction power when flashing it indicates the need to wash the metal grease filter Motor touch sensor key OFF...

Page 18: ...e light If the Motor touch sensor key flashes then replace the battery Remote Control Maintenance Clean the remote control using non abrasive detergents Follow the instructions below in order to repla...

Page 19: ...t be cleaned once a month using non aggres sive detergents either by hand or in the dish washer which must be set to a low temperature and a short cycle When washed in a dish washer the grease filter...

Page 20: ...rrounding area are affecting the ventilation of the hood 3 Blocking in the duct opening or ductwork 4 The direction of duct opening is against the wind 5 Using the wrong size of ducting 1 Metal filter...

Page 21: ...nce misuse abuse accident Improper installation and failure to follow installation instructions When product is used commercially or other than its intended purpose Damaged because of improper connect...

Page 22: ...art Ductless Recirculating Kit charcoal replacement filter Z0F C061 ZRC 00OM Part Description Part halogen bulb 12V 20 W metal filter remote control battery 394 of 1 5V 4 needed Z0B 0009 GF009C Low du...

Page 23: ...23 www zephyronline com...

Page 24: ...24...

Reviews: