background image

WCB3I SERIES

HB0046

INSTALLATION INSTRUCTIONS

INTENDED FOR DOMESTIC COOKING ONLY

INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.

HOMEOWNER: USE AND CARE INFORMATION ON PAGES 12 AND 13.

READ AND SAVE THESE INSTRUCTIONS

BEST; Hartford, Wisconsin  www.BestRangeHoods.com  800-558-1711

BEST; Drummondville, QC, Canada www.BestRangeHoods.ca  866-737-7770

23865 rev. 05

Summary of Contents for WCB3I Series

Page 1: ...NG ONLY INSTALLER LEAVE THIS MANUAL WITH HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGES 12 AND 13 READ AND SAVE THESE INSTRUCTIONS BEST Hartford Wisconsin www BestRangeHoods com 800 558 1711 BEST Drummondville QC Canada www BestRangeHoods ca 866 737 7770 23865 rev 05 ...

Page 2: ...r hood ON when cooking at high heat or when flambeing food i e Crêpes Suzette Cherries Jubilee Peppercorn Beef Flambé c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan filters or in exhaust ducts d Use proper pan size Always use cookware appropriate for the size of the surface element 1 For indoor use only 2 For general ventilating use only Do not use to exhaust...

Page 3: ...MODEL 639 3 X 10 WALL CAP MODEL 634 OR 644 ROOF CAP MODEL 639 3 X 10 WALL CAP OPTIONAL 3 X 10 ELBOW 3 X 10 STANDARD DUCT ADAPTER DAMPER 3 X 10 SUPPLIED WITH HOOD FOR HORIZONTAL OR VERTICAL DISCHARGE UPPER DECORATIVE FLUE LOWER DECORATIVE FLUE ...

Page 4: ...stalled with existing ducts may not achieve their rated airflow Refer to the table below to help you plan the most efficient installation Install wall or roof cap and ensure there is no leak in house insulation Connect metal ductwork to cap and work back towards the hood location Use 2 metal foil duct tape to seal the joints We recommend to install the hood at a minimum distance of 24 from an elec...

Page 5: ...s wall or roof caps Optional flue extension for 10 ft ceilings model AEWCB3SB stainless steel or AEWCB3BLS black stainless steel Glass panel for WCB3I30SBN and WCB3I36SBN models see service parts list on page 15 NOTE During installation protect countertop and or cooktop WARNING When performing installation servicing or cleaning the unit it is recommended to wear safety glasses and gloves HK0059A C...

Page 6: ...les 4 While holding the glass panel pre tighten the previously removed nuts by hand Make sure the glass panel is centered Then using a 3 8 socket tighten the nuts completely 5 Reinstall the electrical compartment cover HD0561 GLASS PANEL STUD NUT 6 PREPARE THE OPENING CAUTION Never use a hammer and screwdriver to remove the vertical or horizontal discharge knock out this would damage the hood inte...

Page 7: ...blower and screws aside 1 Unplug the blower HD0386 RIGHT SIDE MOUNTING SCREW LOCATIONS HD0385 LEFT SIDE MOUNTING SCREW LOCATIONS HE0123 8 INSTALL THE ADAPTER DAMPER HORIZONTAL DISCHARGE Mount the 3 x 10 adapter damper to the back of the hood using 2 no 8 x 3 8 screws included Seal the adapter damper to the hood using metal foil duct tape NOTE The wall ducting must be properly prepared to receive t...

Page 8: ...ered by the decorative flue Place the outlet at a maximum distance of 24 from where the cord exits from the hood The center of the outlet must be positioned at 3 from the center of the future hood location as illustrated beside Make sure this does not interfere with a mounting bracket fastening area or with the decorative flue where the flue touches the wall HE0064A 10 INSTALL HOOD MOUNTING BRACKE...

Page 9: ...od mounting bracket Gently lower the hood until it securely engages the bracket and slightly pull it downward to make sure it is fully engaged NOTE For horizontal discharge only make sure the adapter damper enters the duct opening and seal joint from inside the hood using 2 metal foil duct tape 4 Secure the hood to the wall using 2 no 8 x 3 4 screws for lower holes and 2 no 8 x 1 for upper holes S...

Page 10: ... FLUE HO0271 LOWER FLUE REAR NOTCH Remove protective plastic film covering the lower flue only Peel off both corners at the top of the upper flue note that upper part has one hole on left and right sides see illustration on the right Position the lower flue rear notches down Gently slide upper flue inside lower flue Both lower and upper flues are included with the hood but for a 10 foot ceiling di...

Page 11: ...flue to its bracket using 2 no 8 x 3 8 screws for stainless steel model or 2 no 8 x 1 2 quadrex black screws for black stainless steel model included See illustration beside NOTE Duct not shown in illustration to ease understanding Remove protective plastic film covering the upper flue HO0140 UPPER FLUE MOUNTING BRACKET FRONT VIEW UPPER FLUE 17 REINSTALL HYBRID FILTERS CAUTION Remove protective pl...

Page 12: ...ly explosive and should never be used close to a range Do Regularly wash with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent Always clean in the direction of original polish lines Always rinse well with clear water 2 or 3 times after cleaning Wipe dry completely You may also use a specialized household stainless steel cleaner Don t Use any steel or stainless steel...

Page 13: ...speed 1 button will cause the blower to start on second speed for a very short lapse of time and then resume to speed 1 C MASTER ON OFF When the blower and lights are off press this button to turn the hood on to the last memorized speed level and light intensity If there are no memorized speed level and light intensity speed will be set at level 1 and light intensity at 3 To turn off the blower an...

Page 14: ...Motor Speed J2 120V Motor Lamp 1 J10 J9 Serial Com 5 4 3 2 1 J5 Output J6 External Triac 2 3 4 5 1 2 3 4 1 2 1 2 1 2 3 4 1 2 3 1 2 YEL BLK BLK WHT WHT WHT RED RED RED BLU WHT ORG BLK WHT BLK WHT RED RED WHT BLK WHT RED GRY BRN BLU WHT ORG BLK HE0065A WARNING Risk of electric shock Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards Before con...

Page 15: ...PTION QTY HOOD WIDTH 30 36 1 SV09955XX GLASS PANEL 30 1 SV09956XX GLASS PANEL 36 1 2 SV22427 ELECTRONIC CONTROL 1 1 3 SV09022 TRANSFORMER 1 1 4 62612 LED MODULE 1 2 2 5 SV62053 HYBRID FILTER 15 875 X 14 X 0 5 1 2 2 6 SV08582 INTERNAL BLOWER 1 1 7 62248 LED DRIVER AND CONNECTION HARNESS 1 1 8 SV21189 POWER UNIT 1 1 9 SV09014 HOOD MOUNTING BRACKET 1 1 10 SV13296 ADAPTER DAMPER 1 1 11 SV19134 UPPER F...

Page 16: ...pany will ship the repaired or replaced Product or replacement parts to you at no charge You are responsible for all costs for removal reinstallation and shipping insurance or other freight charges incurred in the shipment of the Product or part to the Company If you must send the Product or part to the Company as instructed by the Company you must properly pack the Product or part the Company is ...

Reviews: