12
8. Electrical connection
WARNING
Electrical Shock Hazard
Warning: Turn off power circuit at the service panel
before wiring this unit.
120 VAC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN ELECTRICAL
JUNCTION BOX WITH 3 WIRES, ONE OF WHICH
(GREEN/YELLOW) SERVES TO GROUND THE
APPLIANCE. TO PROTECT YOU AGAINST ELECTRIC
SHOCK, THE GREEN AND YELLOW WIRE MUST BE
CONNECTED TO THE GROUNDING WIRE IN YOUR
HOME ELECTRICAL SYSTEM, AND IT MUST UNDER
NO CIRCUMSTANCES BE CUT OR REMOVED.
Failure to do so can result in death or electrical
shock.
Facing the front of the range hood, remove the left
knockout and the Junction box cover and install the
conduit connector (cULUS listed) in junction box.
knockout
J-Box
cover
Run 3 wires; black, white and green ,according to the
National Electrical Code and local codes and
ordinances, in 1/2" conduit from service panel to
junction box.
J-Box cover
Conduit
Connect black wire from service panel to black or red in
junction box, white to white and green to green-yellow.
Close junction box cover.
9. Note:
disregard this step if the hood has been fitted
with an integralventilator.
Purchase and install a Remote ventilator (see
paragraph Before installing the hood - Parts not
supplied for model reference).
10. For non-vented (recirculating) installations ONLY:
Install one charcoal filter.
11.
Assemble the canopy with the integral ventilator
housing (chimney structure):
a.
Remove the grease filter (see also Care & Use
section - Charcoal filter).
b.
Thread completely the lower part of the hood
onto the integral ventilator housing rails.
Note: control panel on canopy and electronic
box on chimney structure should be on the same
side.
c.
Make alla cable connections:
LAMPS
CONTROL
PANEL
Inst
allation