11
1. Disconnect blower plug.
5HPRYHVFUHZVIURPLQWHULRURIKRRGERG\
attaching blower plate to top of hood body.
Remove blower and blower plate.
This range hood is equipped standard with a 10” round vertical duct option. To convert from 10” round vertical to
10” round horizontal ducting please following the instructions below.
VERTICAL TO HORIZONTAL DUCTING CONVERSION
Installation –
Horizontal Ducting Conversion
3. Knock out plate A for dual blower horizontal
ducting.
A
4. From inside hood body, position top cover plate
to top of hood body. From outside hood body,
attach top cover plate to top of hood body using
[VFUHZV
5. Position dual blower plate onto interior back wall
mounting brackets inside hood body. Attach by
VFUHZVSUHYLRXVO\UHPRYHGIURPVWHS5H
connect blower plug.
6. Attach 10 inch round blower collar to back of
KRRGXVLQJ0[VFUHZV