Filter Clean Reminder (Standard Baffle Filters fitted):

A set of baffle filters are fitted by the factory. These Baffle Filters are intended to filter out residue from cooking. They

need not be replaced on a regular basis but are required to be kept clean. The 

Filter Clean Reminder

 function in

the microprocessor will automatically indicate by a 

 flashing when the metal filters need to be cleaned after

every 30 hrs. of use. Filters can be cleaned by hand with non-abrasive soap or in a dishwasher.

Filter Clean Reminder:

When 

 flashes on display, the baffle filters installed

are required to be cleaned.
This will occur after every 30 hours of use.

Re-setting Function:

Reset the Filter Clean Reminder timer when filters are
cleaned and re-installed (with hood off).

Press and hold 

 for approx. 5 seconds, the display will

appear; hold for approximately 5 seconds until 

 on

display disappears 

.

The Filter Clean Reminder function is now re-set and a
new 30 hours elapse cycle is initiated.

Clean Filters

display <A> flashes

To Reset

display from  <A>  to <  >

hold 5 secs.

 Features & Controls - T

ouch Controls & Features

Summary of Contents for Cheng Padova CPA-E48ASX

Page 1: ...Date d achat _____________________________________ Fecha de compra Sales Dealer D taillant _____________________________________ Distribuidor LI2ZRA DEC06 0101 READ AND SAVE THESE INSTRUCTIONS Guide...

Page 2: ...e Instructions with this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at service panel and lock out panel before wiring this app...

Page 3: ...methods 9 Preparation 9 Installation Ductwork Calculation Sheet 10 Installation Preliminary Operations 11 Installation Internal Blower 12 13 Top discharge Vertical discharge 12 Rear discharge Horizont...

Page 4: ...al connection 20 Description of the Hood 21 Features Controls Touch Controls Features 22 Description of control panel 22 Features Controls Baffle Filters Change Indicator 23 Maintenance 24 25 Cleaning...

Page 5: ...k Do Not Use This Hood With Any External Solid State Speed Control Device WARNING TOREDUCETHERISKOFARANGETOPGREASEFIRE a Never leave surface units unattended at high settings Boilovers cause smoking a...

Page 6: ...S A listed conduit connector must be provided at each end of the power supply conduit At the range hood and at the junction box Copies of the standards listed may be obtained from National Fire Protec...

Page 7: ...und transition 1 piece Rectangular transition air discharge flange External blower wiring box with wires Template 1 piece Use Care and Installation Guide Warranty PARTS NOT SUPPLIED Duct conduit and a...

Page 8: ...ection for the passage of the discharge pipe for connection to the external motor Consult the template for the passage of pipes under this measurement Hood with external motor Above this measurement a...

Page 9: ...Internal blower installation only PREPARATION Do not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed Fitting material is pro...

Page 10: ...cap 6 Round to 3 1 4 x 10 rect transition 6 Round to 3 1 4 x 10 rect transition 90 elbow 7 8 round 90 elbow 7 8 round 45 elbow 7 8 Round wall cap with damper 7 8 Round roof cap 7 Round to 3 1 4 x 10 r...

Page 11: ...ws We recommend to record and keep all of these components in a safe place ready to be used as required Remove stainless mesh filters See relative paragraph on Maintenance section of this manual Relea...

Page 12: ...ng the 4 fixing screws From the inside of the hood rear side remove cover rectangular transition support from the range hood body unscrewing the 4 fixing screws Install the motor support to the body o...

Page 13: ...blower to the support with 4 screws Provided check that the rectangular outlet of the blower matches with the rectangular slot of the support Note The 4 fixing screws must be screwed in from the outsi...

Page 14: ...ternal Blower Preparation Note for internal blower installation disregard the instruction on this next page and consult the instruction on the previous pages See pages 12 13 Note 2 Refer to the CBE 10...

Page 15: ...er junction box See diagram below Installation External Blower Preparation EXT BLOWER REMOTE FAN UNIT JUNCTION BOX BLACK HIGH RED LOW WHITE COMMON BLUE MED Y G GROUND HOOD CONNECTION WIRE TO WIRE BLAC...

Page 16: ...tuds through the front bodies corresponding holes Use 8 wing nuts to attach and secure See diagrams below 2 3 1 4 6 5 8 7 1 2 3 4 5 6 7 8 3 4 Installation Front Panel NOTE The front panel is not suppl...

Page 17: ...as follows Cutout drywall along marked lines Install wood blocking between studs and make sure it is flush with existing stud front Make sure all mounting screws will anchor to added studs Replace dry...

Page 18: ...ence Position reference CenterLine Duct cover support barcket Installation Installing the Duct Covers Unscrew the 4 screws that fix the section of the Duct Cover Starting collar and release all parts...

Page 19: ...lower bracket WARNING Excessive Weight Hazard Use three or more people to move and install range hood Failure to do so can result in back or other injury 16 Secure hood with screws and washers 17 Con...

Page 20: ...and local codes and ordinances in 1 2 conduit from service panel to junction box J Box cover Conduit Connect black wire from service panel to black or red in junction box white to white and green to...

Page 21: ...21 www zephyronline com Description of the Hood 1 Controls 2 Baffle filter 3 Halogen lamp 4 Incandescent ambient lamp 5 Hood body 6 Duct cover 6 2 2 3 3 4 1 5...

Page 22: ...ase speed level The display indicates level selected 3 Delay Off This is used for programmed shut down of blower and lights 15 minutes after the function is activated Press once a dot flashes in the l...

Page 23: ...an be cleaned by hand with non abrasive soap or in a dishwasher Filter Clean Reminder When flashes on display the baffle filters installed are required to be cleaned This will occur after every 30 hou...

Page 24: ...l retaining clip together the light socket will now protude from the hood allowing you to remove the bulb Be careful when releasing retain clip as it is under pressure to hold it in place Replacement...

Page 25: ...HTING BULB To replace mood lighting bulb remove baffle filter from hood To access lamp area remove the two threaded knobs that fix the cover Unscrew mood lighting bulb counter clockwise and replace wi...

Page 26: ...g area are affecting the ventilation of the hood 3 Blocking in the duct opening or ductwork 4 The direction of duct opening is against the wind 5 Using the wrong size of ducting 1 Metal filter is loos...

Page 27: ...CPC 0112 Front Panel 48 SS CPC 0018 Front Panel 48 Brass CPC 0118 Front Panel 54 SS CPC 0015 Front Panel 54 Brass CPC 0115 50210002 Doluflex 6pc Blank 42 CDO 0042 Doluflex 6pc Blank 48 CDO 0048 Doluf...

Reviews: