background image

26

T

rouble Shooting

After installation, the
unit doesn’t work?

Light works, but motor
is not turning.

The unit is vibrating.

The motor is working,
but the lights are not.

The hood is not venting
out properly.

Metal filter is vibrating.

1. The power source is not turned ON.

2. The power line and the cable locking

connector is not connecting properly.

3. The switch board and control board

wirings are disconnected.

4. The switch board or control board is

defective.

1. The motor is defective, possible

seized.

2. The thermally protected system

detects if the motor is too hot to
operate and shuts the motor down.

3. Damaged condenser.

1. The motor is not secure in place.

2. Damaged blower wheel.

3. The hood is not secured in place.

1. Defective halogen bulb.

2. The light bulb is loose.

1. The hood might be hanging to high

from the cook top.

2. The wind from the opened windows

or opened doors in the surrounding
area are affecting the ventilation of
the hood.

3. Blocking in the duct opening or

ductwork.

4. The direction of duct opening is

against the wind.

5. Using the wrong size of ducting.

1. Metal filter is loose.

Issue

Cause

What to do

1. Make sure the circuit breaker and the

unit’s power is ON.

2. Check the power connection with the

unit is connected properly.

3. Make sure the wirings between the

switch board and control board are
connected properly.

4. Change the switch board or control

board.

1. Change the motor.

2. The motor will function properly after

the thermally protected system cool
down.

3. Change the condenser.

1. Tighten the motor in place.

2. Change the blower wheel.

3. Check the installation of the hood.

1. Change the halogen bulb.

2. Tighten the light bulb.

1. Adjust the distance between the cook

top and the bottom of the hood within
24” and 32” range.

2. Close all the windows and doors to

eliminate the outside wind flow.

3. Remove all the blockage from the duct

work or duct opening.

4. Adjust the duct opening direction.

5. Change the ducting to at least 8” or

higher.

1. Change the metal filter.

Summary of Contents for Cheng Padova CPA-E48ASX

Page 1: ...Date d achat _____________________________________ Fecha de compra Sales Dealer D taillant _____________________________________ Distribuidor LI2ZRA DEC06 0101 READ AND SAVE THESE INSTRUCTIONS Guide...

Page 2: ...e Instructions with this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at service panel and lock out panel before wiring this app...

Page 3: ...methods 9 Preparation 9 Installation Ductwork Calculation Sheet 10 Installation Preliminary Operations 11 Installation Internal Blower 12 13 Top discharge Vertical discharge 12 Rear discharge Horizont...

Page 4: ...al connection 20 Description of the Hood 21 Features Controls Touch Controls Features 22 Description of control panel 22 Features Controls Baffle Filters Change Indicator 23 Maintenance 24 25 Cleaning...

Page 5: ...k Do Not Use This Hood With Any External Solid State Speed Control Device WARNING TOREDUCETHERISKOFARANGETOPGREASEFIRE a Never leave surface units unattended at high settings Boilovers cause smoking a...

Page 6: ...S A listed conduit connector must be provided at each end of the power supply conduit At the range hood and at the junction box Copies of the standards listed may be obtained from National Fire Protec...

Page 7: ...und transition 1 piece Rectangular transition air discharge flange External blower wiring box with wires Template 1 piece Use Care and Installation Guide Warranty PARTS NOT SUPPLIED Duct conduit and a...

Page 8: ...ection for the passage of the discharge pipe for connection to the external motor Consult the template for the passage of pipes under this measurement Hood with external motor Above this measurement a...

Page 9: ...Internal blower installation only PREPARATION Do not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed Fitting material is pro...

Page 10: ...cap 6 Round to 3 1 4 x 10 rect transition 6 Round to 3 1 4 x 10 rect transition 90 elbow 7 8 round 90 elbow 7 8 round 45 elbow 7 8 Round wall cap with damper 7 8 Round roof cap 7 Round to 3 1 4 x 10 r...

Page 11: ...ws We recommend to record and keep all of these components in a safe place ready to be used as required Remove stainless mesh filters See relative paragraph on Maintenance section of this manual Relea...

Page 12: ...ng the 4 fixing screws From the inside of the hood rear side remove cover rectangular transition support from the range hood body unscrewing the 4 fixing screws Install the motor support to the body o...

Page 13: ...blower to the support with 4 screws Provided check that the rectangular outlet of the blower matches with the rectangular slot of the support Note The 4 fixing screws must be screwed in from the outsi...

Page 14: ...ternal Blower Preparation Note for internal blower installation disregard the instruction on this next page and consult the instruction on the previous pages See pages 12 13 Note 2 Refer to the CBE 10...

Page 15: ...er junction box See diagram below Installation External Blower Preparation EXT BLOWER REMOTE FAN UNIT JUNCTION BOX BLACK HIGH RED LOW WHITE COMMON BLUE MED Y G GROUND HOOD CONNECTION WIRE TO WIRE BLAC...

Page 16: ...tuds through the front bodies corresponding holes Use 8 wing nuts to attach and secure See diagrams below 2 3 1 4 6 5 8 7 1 2 3 4 5 6 7 8 3 4 Installation Front Panel NOTE The front panel is not suppl...

Page 17: ...as follows Cutout drywall along marked lines Install wood blocking between studs and make sure it is flush with existing stud front Make sure all mounting screws will anchor to added studs Replace dry...

Page 18: ...ence Position reference CenterLine Duct cover support barcket Installation Installing the Duct Covers Unscrew the 4 screws that fix the section of the Duct Cover Starting collar and release all parts...

Page 19: ...lower bracket WARNING Excessive Weight Hazard Use three or more people to move and install range hood Failure to do so can result in back or other injury 16 Secure hood with screws and washers 17 Con...

Page 20: ...and local codes and ordinances in 1 2 conduit from service panel to junction box J Box cover Conduit Connect black wire from service panel to black or red in junction box white to white and green to...

Page 21: ...21 www zephyronline com Description of the Hood 1 Controls 2 Baffle filter 3 Halogen lamp 4 Incandescent ambient lamp 5 Hood body 6 Duct cover 6 2 2 3 3 4 1 5...

Page 22: ...ase speed level The display indicates level selected 3 Delay Off This is used for programmed shut down of blower and lights 15 minutes after the function is activated Press once a dot flashes in the l...

Page 23: ...an be cleaned by hand with non abrasive soap or in a dishwasher Filter Clean Reminder When flashes on display the baffle filters installed are required to be cleaned This will occur after every 30 hou...

Page 24: ...l retaining clip together the light socket will now protude from the hood allowing you to remove the bulb Be careful when releasing retain clip as it is under pressure to hold it in place Replacement...

Page 25: ...HTING BULB To replace mood lighting bulb remove baffle filter from hood To access lamp area remove the two threaded knobs that fix the cover Unscrew mood lighting bulb counter clockwise and replace wi...

Page 26: ...g area are affecting the ventilation of the hood 3 Blocking in the duct opening or ductwork 4 The direction of duct opening is against the wind 5 Using the wrong size of ducting 1 Metal filter is loos...

Page 27: ...CPC 0112 Front Panel 48 SS CPC 0018 Front Panel 48 Brass CPC 0118 Front Panel 54 SS CPC 0015 Front Panel 54 Brass CPC 0115 50210002 Doluflex 6pc Blank 42 CDO 0042 Doluflex 6pc Blank 48 CDO 0048 Doluf...

Reviews: