Installation –

 Hood Specifications

FRONT

SIDE

TOP of HOOD

TOP SUPPORT FRAME

(top view)

10 

3/8

23 

15/16

29 

15/16

”, 35 

3/16

25 

9/16

23-7/8”

1/

2

10 

3/4

1 3/4”

11 

5/

8

5/

8

Min. Ducted - 28”
Min. Recirc. - 29”
Maximum   -  37”

(top of electrical box

)

13 

3/4

5/16

C/L

6”

8”

3/

4

1/4

3/4

3/16

5/

8

elec. k/o

Summary of Contents for brisas BML-E30BG

Page 1: ...Use Care and Installation Guide Model number Serial Number OCT20 0301 XP022528 1 BML E30BG BML E36BG...

Page 2: ......

Page 3: ...rance 6 Ducting Options 7 Hood Specifications 8 Mounting the Hood 9 11 Ductless Recirculating 12 FEATURES CONTROLS Touch Controls 13 MAINTENANCE Hood and Filter Cleaning 14 Lights 15 ACT CONVERSION 16...

Page 4: ...EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out im...

Page 5: ...in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances...

Page 6: ...ARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED Ducting conduit and all installation tools Cable connector if required by local codes Duct cover extension accessory Recirculating kit accessory A B Front o...

Page 7: ...lumn 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 6 roundto 3 1 4 x 10 rect transition 1 Ft x Ft 6 r...

Page 8: ...d too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will loose its performance and efficiency If available also refer to range manufacturer s h...

Page 9: ...s using the recirculating option Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting Options...

Page 10: ...IDE TOP of HOOD TOP SUPPORT FRAME top view 10 3 8 23 15 16 29 15 16 35 3 16 25 9 16 23 7 8 3 1 2 10 3 4 1 3 4 11 5 8 4 5 8 Min Ducted 28 Min Recirc 29 Maximum 37 top of electrical box 13 3 4 5 1 6 C L...

Page 11: ...screws 2 screws for each support frame arm FIG A 2 3 Lift support frame assembly up to the ceiling making sure the the word front on the top support frame faces the front of the hood where the contro...

Page 12: ...support frame FIG F Slide hood towards the narrow end of key holes to lock in place Hand tighten each of the 4 screws to secure hood to bottom of support frame Install 1 4mm x 12mm long safety screw i...

Page 13: ...If using hood in ductless recirculating mode you must install the air diverter plate to the Top Support Frame prior to assembling the duct covers Turn to page 12 for more details 10 Secure Top Duct Co...

Page 14: ...ng and the optional charcoal filters help to purify fumes exhausted from cooking for re circulation RECIRCULATING KIT REQUIRED IF NO DUCTING IS USED Kit includes charcoal filters charcoal filter brack...

Page 15: ...and regulations To verify the maximum fan CFM With hood off press and hold the power button for five seconds If all three fan speed indicators illuminate default maximum CFM If two speed level indicat...

Page 16: ...an cotton cloth or micro fiber cloth and buff in the direction of the stainless steel grain Aluminum Mesh Filters The aluminum mesh filters installed by the factory are intended to filter out residue...

Page 17: ...d accessories page for part s and contact information To replace LED light strip 1 Remove aluminum mesh filters 2 Remove light panel by two screws 3 Disconnect LED light strip quick connector 4 Push i...

Page 18: ...nother clearly visible location NOTE After re positioning the jumper and powering on the hood the CFM cannot be changed again To verify if your installer enabled ACT With hood off press and hold the p...

Page 19: ...17 Wiring Diagrams Fan 315W Lamp LED 5W 2 Total Max 325W 2 7A Voltage 120V 60Hz Power consumption UL file number E127334 THERMALLY PROTECTED Model BML E30BG BML E36BG Fan On Off Lights...

Page 20: ...brating 1 The motor is not secure in place 1 Tighten the motor in place 2 Damaged blower wheel 2 Replace the blower 3 The hood is not secured in place 3 Check the installation of the hood 4 The switch...

Page 21: ...eplacement Parts LED Light Strip 5W Z0B0043 Aluminum Mesh Filter 50200043 Optional Accessories Recirculating Kit BRC 0007 Replacement Charcoal Filter Z0F C094 Duct Cover Extension up to 12 ceiling B1C...

Page 22: ...ranty All Products must be installed by a qualified professional installer to be eligible for warranty repairs or service Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHAL...

Reviews: