background image

CLEANING AND MAINTENANCE

SELF CLEAN FEATURE

CONTROLS & FEATURES

CONTROLS & FEATURES 

(Models AK2500, AK2536)

I

II

III

3 Speed Level Indication

Delay Off Indication

Delay Off

3

Blower On/Off

1

Cycle Speed Selection

2

Cycle Lights On/Dim/Off

4

0      I       II      III

Blower On/Off/Speed Selection

1

Lights On/Off

2

Models: AK6500, AK6536, AK6542, AK2500, AK2536   

Page 8

Models: AK6500, AK6536, AK6542, AK2500, AK2536   

Page 9

Using Self Cleaning:

Models AK6500, AK6536, AK6542, AK2500, AK2536 hoods are designed with a self cleaning feature.
The centrifugal blower system automatically liquefies cooking residue accumulated in its internal
housing, and deposits the residue in the cleaning cup. Nevertheless, grease from cooking can also
dry and adhere in the internal housing. Running the self clean function periodically will flush out
accumulated residue in the range hood’s internal housing.

Cleaning Frequency:

Cleaning should be completed approximately once a month under normal use.

Detergent:

Non-corrosive, non-abrasive grease cutting spray detergents are recommended.

Self Clean:

Turn blower on lowest speed for cleaning.

With nozzle on ‘spray’, squirt the grease cutting 
detergent through the safety grill,directly onto
blower blades 10-15 times.

Allow self cleaning to complete for 5 minutes,
turn blower off.

Remove cleaning cup. Clean w/ mild detergent
or in dishwasher under normal wash cycle.

(If desired, repeat above steps with water 
to rinse out detergent)

WARNING:

Use only non-corrosive & non-abrasive 

grease cutting detergents.

DO NOT USE OVEN CLEANERS.

Blower On/Off

By pressing         , the blower is turned On and Off.

Cycle Speed Selection

Cycle through 3 speed levels by pressing         , the display indicates level selected.

Delay Off

This switch is used for programmed shut down of blower and lights 5 minutes after the function is
activated. Press         once, the flashing indicator to the left indicates the function is on. The hood
will completely shut down in 5 minutes.

Cycle Lights On/Dim/Off

Switch lights On         by selecting this switch. To Dim lights, activate         again. Selecting
one more time, will turn lights Off

1

2

3

4

Blower On/Off/Speed Selection

This switch turns the blower on and off and controls the speed selection.

is off,

I

is low speed,

II

is medium speed and 

III

is high speed.

Lights On/Off

Turn lights on 

I

or off 

0

with this switch.

1

2

CONTROLS & FEATURES 

(Models AK6500, AK6536, AK6542)

0   

   I

    

   I

Summary of Contents for AK2500 series Use

Page 1: ...due to negligence and the warranty of the unit automatically expires due to improper maintenance NOTE Please check www zephyronline com for revisions before doing any custom work Read all Instruction...

Page 2: ......

Page 3: ...s crawl spaces ceiling attics or garages All exhaust must be ducted to the outside Use metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or...

Page 4: ...ALLATION MOUNTING THE RANGEHOOD ELECTRICAL All Electrical work must by performed by qualified electrician or person with similar technical know how and background For personal safety remove house fuse...

Page 5: ...sition adapter Rectangular rear cap pre mounted 3 1 4 x10 starting collar 3 1 4 x10 Vertical Discharge 1 Remove pre mounted 6 transition adapter or duct opening 3 Mount the 3 1 4 x10 starting collar o...

Page 6: ...r cleaning With nozzle on spray squirt the grease cutting detergent through the safety grill directly onto blower blades 10 15 times Allow self cleaning to complete for 5 minutes turn blower off Remov...

Page 7: ...ngent expenses The natural wear of finish and wear due to improper maintenance use of corrosive and abrasive cleaning products pads and oven cleaner products Chips dents or cracks due to abuse misuse...

Page 8: ...oof of purchase with date ready for warranty issues Or write to Zephyr Corporation Service and Warranty Department 395 Mendell Street San Francisco CA 94124 TO OBTAIN SERVICE UNDER WARRANTY or any Ser...

Page 9: ...due to negligence and the warranty of the unit automatically expires due to improper maintenance NOTE Please check www zephyronline com for revisions before doing any custom work Read all Instruction...

Page 10: ......

Page 11: ...son Utilisez des conduits d a ration en m tal seulement Fixez toutes les pi ces du conduit l aide de vis t le et isolez tous les joints l aide de ruban conduit ou ruban r flecteur certifi s Quelques o...

Page 12: ...scell es avec le ruban adh sif en toile INSTALLATION MONTAGE DE LA HOTTE LECTRICIT Tous les travaux lectrique doivent tre effectu s par un lectricien qualifi ou une personne avec l exp rience techniqu...

Page 13: ...tical de 3 x 10 1 Retirez l adaptateur de 6 pr mont l ouverture du conduit Laisses le profil de calfeutrement fix son emplacement original 3 Installez le collier de fixation principal de 3 x 10 sur l...

Page 14: ...lames du ventilateur de 10 15 fois avec du d tergent Laissez fonctionner l autonettoyage pendant 5 minutes puis teignez le ventilateur Retirez les contenants nettoyage Nettoyez avec du d tergent doux...

Page 15: ...ur une utilisation personnelle normale dans les 48 tats du territoire principal am rican ainshi que dans les tats d Hawaii et de Washington D C Au Canada et en Alaska cette garantie est limit e Il pou...

Page 16: ...duit avec date pour l application de la garantie Ou crivez Zephyr Corporation Service and Warranty Department 395 Mendell Street San Francisco CA 94124 POUR OBTENIR DU SERVICE SOUS GARANTIE Ou pour to...

Reviews: