15
Decorative Mesh Filter Clean Reminder (metal mesh filter)
Whether your hood is installed as an exhaust or purifying unit, a decorative mesh filter is fitted by the factory. This
mesh filter is intended to filter out residue from cooking. It need not be replaced on a regular basis but is required to
be kept clean. After every 30 hours of use the Filter Clean Reminder function in the microprocessor will automati-
cally remind you by a flashing when the mesh filter needs to be cleaned. The filter can be cleaned by hand
with non-abrasive soap or in a dishwasher. A heavily soiled filter should also be soaked in grease cutting
detergent prior to cleaning.
Decorative Mesh Filter Clean Indicator
When flashes on display, the mesh filter installed is
required to be cleaned. This will occur after every 30
hours of use.
Re-setting Function
Reset the filter clean reminder timer when filter is cleaned
and re-installed. With hood off, press and hold for
approximately 5 seconds until on display disappears
. . The filter clean reminder function is now reset
and a new 30 hours elapse cycle is initiated.
F
Clean Filters
display < F > flashes
F
hold 5 sec.
display from < F > to < >
To Reset
F
F
F
Charcoal Filter Replace Reminder (charcoal filter, if installed)
When your hood is installed as a recirculating unit it must be fitted with a charcoal filter to purify exhaust and fumes
from cooking and then recirculate the air within the home. This charcoal filter must be replaced after every 120 hours
of use. The charcoal filter should never be cleaned or placed in a dish washer.
The charcoal filter replace reminder function in the microprocessor needs to be switched on. When switched on, the
microprocessor will elapse and count usage time. When charcoal filter replacement is needed a flashing will
appear on the display.
C
Setting the Charcoal Filter Replace Reminder
With hood off, hold for approximately 5 seconds.
The display will change from (exhaust mode) to
(recirculating mode). This indicates that the elapse
timer function is switched on and charcoal filter is being
used.
Charcoal Filter Replace Indicator
When the display starts flashing, the charcoal filter
needs to be replaced. Purchase replacement charcoal
filters from Zephyr.
Re-setting Function
After charcoal filter is replaced, with hood off, press and
hold for apprimately 5 seconds until on the
display disappears . The filter change reminder is
now re-set and a new 120 hour elapse cycle is initiated.
C
C
C
C
hold 5 sec.
display from < - > to < C >
Set Mode
Set Mode
display < C > flashes
Change FIlter
C
hold 5 sec.
display from < C > to < >
To Reset
C
Features & Controls –
Filter Clean and Replace Reminder
Summary of Contents for Genova AK7336AS
Page 2: ...www zephyronline com...
Page 21: ...19 Maintenance Wiring Diagram 370W 270W 3 5A 3 5A...
Page 26: ...www zephyronline com...
Page 30: ...Liste du mat riel 4 www zephyronline com 2 M4 x 1...
Page 34: ...8 www zephyronline com Installation 6SpFL FDWLRQV GH OD KRWWH LC...
Page 40: ...14 www zephyronline com Commandes RPPDQGHV j HI HXUHPHQW...
Page 41: ...15 Commandes QGLFDWHXU GH FKDQJHPHQW GHV OWUHV j FKDUERQ...
Page 42: ...16 www zephyronline com COMMANDES QGLFDWHXU GH QHWWR DJH GHV OWUHV j WDPLV PpWDOOLTXHV...
Page 46: ...20 www zephyronline com 3 5A 3 5A Entretien Sch ma de c blage...