2
Burner Maintenance
1) Check and replace electrode insulators if cracked.
2) Clean burnt buss bars.
3) Clean carbon off electrodes.
4) Clean carbon off oil nozzle (use caution not to
scratch face of nozzle or orifice).
5) Check for a loose oil nozzle. Note: Check with
dealer and/or replace nozzle with proper nozzle.
5. Gently replace burner gun assembly in air tube. CAUTION:
Do not force. Forcing will cause electrode misalignment.
6. Reinstall the retaining nut.
7. Reinstall the oil line making sure both ends are tight.
8. Partially close transformer. Check if buss bars align and
contact the transformer electrodes. If buss bars do not
contact, see Buss bar Alignment.
9. Close transformer, reposition retainer and tighten screw.
Accessories
p/n Y01-00041 Gauge-0- 200 PSI
p/n Z09-00004
Bacharach Smoke Tester
p/n Y01-00090 Allen Wrench 1/8” #8
p/n z01-00092
Fuel Nozzle Changing Wrench
Electrode Assembly Adjustment
1. Loosen screws holding electrode assemblies.
2. Raise electrode tips 5/32” above surface plane or end of oil
nozzle.
3. Place each electrode tip 5/16” from center of spray nozzle
hole, maintaining previous measurement.
4. Spread electrode tips to 1/8” gap maintaining previous
measurements.
5. When the proper measurements are obtained, gently tighten
screws that hold electrode assembly in place. CAUTION: Do
not over tighten, as this will cause the electrode insulator to
fail.