background image

GB-11

EBZ7500

G

B

9. Maintenance

Maintenance,  replacement,  or  repair  of  the  emission  control  device  and  systems  may  be 

performed by any non-road engine repair establishment or individual.

System/components

Procedure

Daily

or

Before use

Every

25 hours 

after

Every

50 hours 

after

Every

100 hours 

after

Air Filter 

Prefilter

Inspect / Clean

Air Filter 

Paper Filter

Inspect / Replace

Fuel Leaks

Inspect / Replace

Fuel Filter

Inspect / Replace

Fuel Line

Inspect / Clean

Spark Plug

Inspect / Clean

Muffler

Inspect / Clean

Muffler Spark Arrester

Inspect / Clean

Cooling Systrem

Inspect / Clean

Screws / Nuts / Bolts

Tighten

Air Inlet Net

Inspect / Clean

Cylinder Exhaust Port

Inspect / Clean

WARNING

Make sure that the engine has stopped and is cool 
before performing any service to the blower. Contact 
with rotating blower fan or hot muffler may result in 
a personal injury.

AIR CLEANER

•  Never operate the blower without the air filter or with 

a deformed filter element because unfiltered dusty air 
will quickly ruin the engine. 

• 

Check the air cleaner before use.

 

  A  clogged  air  filter  may  increase  fuel  consumption 

while cutting down the engine power. 

•  Never clean a paper filter by striking it with or against 

another object. The filter may be damaged and resul-
tant dust contamination can diminish engine perfor-
mance.

CLEANING AIR FILTER:

1.  Unscrew  2  knob  bolts  and  remove  the  air  cleaner 

cover. Then remove a prefilter mounted inside the air 
cleaner cover. 

(1) Knob Bolt
(2) Prefilter
(3) Paper Filter

2.  Wash the prefilter in fresh, non flammable cleaning 

solution (ex. warm soapy water) and then dry.

  (Clean the air filter once in a week.)
3.  Exchange  the  paper  filter  element  with  new  one  in 

case it has been contaminated.

WARNING

•  This prefilter is dry type.
•  Never  wash  the  prefilter  in  oleaginous  cleaning 

solution.

•  Do not clean a paper filter by striking it.

FUEL FILTER

•  A clogged fuel filter may cause poor acceleration of 

the  engine.  Check periodically to  see  if  the filter  is 
clogged with dirt. The filter can be taken out of the 
fueling port using a small wire hook. Disconnect the 
filter assembly from the fuel pipe and unhook the re-
tainer to disassemble it. Clean the components with 
gasoline.

(1) Screen   (2) Element
(3) Holder    (4) Retainer

SPARK PLUG

•  The  spark  plug  may  gather  carbon  deposits  on  its 

firing end with reasonable use. Remove and inspect 
the spark plug every 25 hours and clean the elec-
trodes as necessary with a wire brush. The spark gap 
should be adjusted to .025 in (0.6~0.7mm).

•  Plug manufacturers recommend replacing the plug 

twice a year to avoid unexpected plug failure in a 
job.

01-EBZ7500_GB3lan_212_一.indd   11

12.12.19   1:51:26 PM

Summary of Contents for EBZ7500

Page 1: ...EBZ7500 OWNER S MANUAL BLOWER 115 56 01 94 212 G B Original Instruction 01 EBZ7500_GB3lan_212 indd 1 12 12 19 1 51 18 PM...

Page 2: ...chanical failure breakdown or damage NOTE This mark indicates hints or directions useful in the use of the product Contents 1 Parts location 2 2 Specifications 3 3 Warning labels on the machine 3 4 Sy...

Page 3: ...machine improperly could result in accidents causingserious injury or death Read this manual carefully and practice using the blower until you are fully acquainted with all operations and have learne...

Page 4: ...you are tired ill or upset or if you are under the influence of alcohol drugs or medication 2 To reduce the risk of hearing loss associated with sound level s hearing protection is required 3 To reduc...

Page 5: ...filters WORKING PLAN When planning your work sched ule allow plenty of time to rest Limit the amount of time over which the product is to be used continuously to somewhere around 30 40 minutes per se...

Page 6: ...ociated with thrown objects a Watch out for children pets open windows or freshly washed cars and blow debris safely away b Use the full blower nozzle exten sion so the air stream can work close to th...

Page 7: ...ure 5 When replacing the any other part or any lubricant always be sure to use only ZENOAH prod ucts or products which have been certified by ZENOAH for use with the ZENOAH product 6 In the event that...

Page 8: ...embly of flexible pipe to blower elbow NOTE Pipe end can be connected with Pipe straight in two opposing directions a b as described in a Operator can feel Light weight body than usual due to the air...

Page 9: ...s sufficient agita tion is necessary for the engine to last long Be care ful that if the agitation is insufficient there is an in creased danger of early piston seizing due to abnor mally lean mixture...

Page 10: ...mature damage to the starter Do not let a person stand near the blower or the exhaust port 5 Once the engine is running gradually open the choke if it was set closed and let the engine run at idle spe...

Page 11: ...ter may be damaged and resul tant dust contamination can diminish engine perfor mance CLEANING AIR FILTER 1 Unscrew 2 knob bolts and remove the air cleaner cover Then remove a prefilter mounted inside...

Page 12: ...4 Diffuser SPARK ARRESTER The muffler is equipped with a spark arrester to prevent red hot carbon from flying out of the exhaust outlet Periodically inspect and clean as necessary with a wire brush In...

Page 13: ...ot apply liquid type screw lock glue on screws or bolts used to fix plastics components Adherence of this type of glue may cause cracks on plastics and end up with the breakage 10 Storage BEFORE STORI...

Page 14: ...RATOR MANUAL FOR PROPER USE AND MAINTENANCE OF THE UNITS ACCIDENT MISHANDLING ALTERATION ABUSE IM PROPER LUBRICATION USE OF ANY PARTS OR ACCES SORIES OTHER THAN THOSE SPECIFIED BY THE COM PANY OR OTHE...

Reviews: