Summary of Contents for Securel v2

Page 1: ...Securel v2 Access Controller Encrypted Relay ZIOSECV2 USER MANUAL dsñkmfroi Application Program Version 1 2 User manual edition 1 2 _a www zennio com ...

Page 2: ... v2 Error Marcador no definido 1 2 Access Control System 4 1 3 Installation 4 2 Pairing with IWAC 7 3 LED Notification 8 4 Securel v2 status 9 4 1 Default status 9 4 2 Status after programming 9 4 3 Status after bus failure 9 4 4 Status after power failure 9 5 Configuration 10 5 1 General 10 ANEXO I Communication Objects 12 ...

Page 3: ...crypted information to communicate with the access control device for example IWAC Display v3 In this way the inviolability of the system is assured The most notable features of this device are Acting on electric strike using semiconductor element Encrypted serial communication with the access control device for door opening Small dimensions 39 x 39 x 14mm Configuration of the door opening time LE...

Page 4: ... When the Open command is correctly received from IWAC access granted Securel v2 will release the lock for a while to open the door BMS Building Management System computer system that assumes the integral automation of the building Z Access application that allows employees to record access cards In addition by means of a specific module of the BMS system permits the joint coordination of the diff...

Page 5: ...minal of the electric strike output as neutral 2 Moreover the relay also will power IWAC with 24VDC through its remaining terminals 1 and 3 Finally the Securel v2 communicates with IWAC through the Tx Rx transmit and receive terminal 4 It should be recalled that in order to ensure the inviolability of our access control system it is necessary to locate Securel v2 inside the room of the management ...

Page 6: ...et detailed information about the technical features of this device as well as on the installation and security procedures please refer to the corresponding Datasheet bundled with the original package of the device and also available at www zennio com SECURE ZONE IWAC Display v3 24VDC Power Supply 24VDC Electric Strike Securel v2 ...

Page 7: ...th any IWAC before it will be in pairing mode Only connect the Securel v2 to the IWAC desired to pair with and they will be automatically paired If Securel v2 is paired with an IWAC press the programming button for three seconds to remove the pairing Securel v2 is then in pairing mode Connect the Securel v2 to the IWAC desired to pair with and they will be automatically paired Notes Whenever Secur...

Page 8: ...or closed When the programming mode is activated only this mode will be notified by lighting the LED in red Note Securel v2 can be paired or open close the relay while the programming mode is active but only the programming mode is notified i e the LED remains lighting in red A long press longer than three seconds will always activate the pairing mode regardless of if the programming mode is activ...

Page 9: ...out any action on the lock until a first order is received from the IWAC If Securel v2 was not paired remains in pairing mode 4 3 STATUS AFTER BUS FAILURE A KNX bus power failure does not imply any change in the device status because Securel v2 has external power supply It will continue to operate normally although logically it will not send the Heartbeat object to the bus 4 4 STATUS AFTER POWER F...

Page 10: ...l From this screen it is possible to configure all the required functionality Figure 4 General Configuration Opening Time time the lock remains open after receiving the opening command Range 10 to 255 tenths of a second 30 by default The maximum recommended opening time will depend on the lock type Heartbeat Periodical Alive Notification incorporates a one bit object to the project Heartbeat Objec...

Page 11: ...fter download or bus failure takes place with a delay of up to 255 seconds to prevent bus overload The following sendings match the period set Note Take into account that Securel v2 must be paired with the corresponding access control device IWAC to work properly for further information see section 2 ...

Page 12: ...ny other values permitted by the bus according to the object size may be of any use or have a particular meaning because of the specifications or restrictions from both the KNX standard or the application programme itself Number Size I O Flags Data type DPT Functional Range Name Function 1 1 Bit C T DPT_Trigger 0 1 Heartbeat Object to Send 1 Sending of 1 Periodically ...