1. Product description
Pulse to wireless M-Bus or LPWAN Converter
The PDC (Pulse Data Capture) module is used for
the integration of meters with pulse output in radio
systems or smart metering systems.
Typical applications:
■
Wireless remote readout of water meters with
walk-by or drive-by system
■
Radio transmission of the readings to mobile
or stationary receivers
By the means of the PDC module conventional me-
ters with pulse output can be integrated in radio or
M-Bus systems in an easy and cost-efficient way.
For this purpose, the pulse output of the meter
is to be connected with the battery powered PDC
module. For ZENNER water meter retrofittable with
pulser ZENNER provides corresponding PDC mod-
ules with ex-works installed pulse output.
The PDC module is available in following versions:
■
wireless M-Bus radio module according to
OMS-Standard (868 MHz), EN 13757-4
■
LPWAN-Radio module for LoRaWAN™
The EDC modules are each powered from a lithium
battery, which - depending of the version - has a
lifetime of up to 15 years (wM-Bus) and 10 years
(LoRaWAN
TM
).
Scope of delivery
PDC module with mounting kit and installation
instructions, possibly with Pulse Generator con-
nected ex-works for specific ZENNER water meter.
Technische Änderungen
2. General technical data
Battery voltage
3.6V
Pulse duration
min. 20 ms
Pulse pause
min. 20 ms
Battery lifetime
depending on the mode (number
of channels used, wM-Bus package
type, transmission frequency.
up to 15 years is possible; for
LoRaWAN upto 10 years
Ambient temperature
10°C…40°C,
-15°C ....60°C (temporarily)
Protection class
Electronics filled with resin to
avoid moisture entering.
Requirements for pulse
output incl. connection
cable
max. 300 Ω or max. max. 0,3V
(ON) / max. 1000pF (OFF)
Data logger (LoRaWAN)
Annual due date values:
2
Monthly values
18 plus 18 half-monthly
values
Daily values
max. 32
Data logger (wM-Bus)
Annual due date values:
max. 4
Monthly values
18 plus 18 half-monthly
values
Daily values
max. 96
Quarter-hour values
max. 96
Fig. 1: PDC
incl. Reed-
switch for
MNK-N
Fig. 2: PDC
incl. Reed-
switch for
MTKD-N
Fig. 3: PDC incl.
EDC Pulse mod-
ule for meter
type “-M”