Page 14 of 32
802700NZ - Commercial Installation Instructions - Aug 2015 - V2.01
2.1
Ventilation for Boiling Models
Proper air circulation must be provided for all models. The system will operate correctly only if the
recommended air gaps are achieved during installation. The minimum requirement is for a 50mm air gap either
side and 300mm above of the undersink unit.
It is important that the 4mm door buffers (For all installations ) are fitted to the inside edge of the
cupboard door to allow suficient air circulation inside the cupboard. (See the diagram below).
IMPORTANT:
See section 6 for clearances.
When installing air flow ducts, the following tools will be required:
•
Jigsaw and 12mm Drill
•
Keyhole or Wall Board saw.
Section 2
Ventilation
4mm Buffer
Pad to ensure
ventilation gap
Min 300mm