background image

804546NZ - BW_HB Small_09.18 v1.02 

Page 9 of 24

Warning: The element will be turned on at 

the next step. Failure to ensure water is not 

available at the tap outlet will burn the element.

Then touch   [Next] to begin the calibration process.

This screen shows the boiling calibration status while it 

heats the water to boiling point. The water temperature is 

shown in the first parameter.
It takes about 5 minutes to boil the water. When calibration 

is complete, the normal operating home screen will appear 

(see next section on menu operation).
The tank will then commence filling and heating. Boiling 

water will be maintained thereafter. Initial heating and filling 

periods are shown in the table below. 

Inlet water temperature

15°C

10°C

3.0 Litre models

16 min

17 min

5.0 Litre models

16 min

17 min

7.5 Litre models

23 min

24 min

 Step 8 – Commissioning - Calibration

Touch “Start” and allow 5 litres of water to flow through the 

filter (this takes about 10min of flushing). Water must trickle 

out of the vent outlet (at 0.5L/min). Touch “Stop” when 

complete. Note there will be no water flow if a filter is not 

installed.
Touch   [Next] after flushing.

Return the filter valve to the “Filtered” position (Fig.3) and 

then touch   [Done].
Continue into the following section (Step 8).

Once water is available, close the dispense tap outlet.

This follows on from Step 7 (above).

Ensure the dispense tap outlet is open (push safety lock 

button and pull for the latched open position – Fig.2). Allow 

the tank to fill until water is available at the dispense tap 

outlet. Correct the flush valve position if water comes out of 

the vent. 
With water available touch   [Next].

Installation Procedures

Summary of Contents for Hydroboil Series

Page 1: ...boil 3 Litre White 303661 Zenith Hydroboil 3 Litre Stainless Steel 305662 Zenith Hydroboil 5 Litre White 305661 Zenith Hydroboil 5 Litre Stainless Steel 307662 Zenith Hydroboil 7 5 Litre White 307661...

Page 2: ...by persons including children with reduced physical sen sory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the ap...

Page 3: ...rosive or abrasive cleaners to clean the case of the heater Frost protection If this heater is located where ambient air temperature could fall below 5 C when the heater is not in use do not turn off...

Page 4: ...increased only if essential for filling larger vessels Provide clearance for service access of not less than 100 mm top 150 mm left 20 mm right Mark corner positions for the heater on the wall so as t...

Page 5: ...ter pressure requirements Minimum 150 kPa maximum 700 kPa A 500 kPa pressure limiting valve is part of the Hydroboil water inlet assembly 3 2 Venting A vent at the base of the heater must be plumbed t...

Page 6: ...ect the Live Active and Neutral wires of the concealed power cable through the rear access opening to the green terminal block on the PCB Crimp a 6 3 mm QC female spade connector to the earth wire of...

Page 7: ...se through 90 until fully engaged 20mm Step 6 Installing Filter Installation Procedures Fit the case wrapper to unit as shown in the picture below Note make sure the filter guide has already been inst...

Page 8: ...red safety lock button on the right hand side of the unit while pulling the tap lever backwards to latch it open see Fig 2 and next section for operating procedure Turn the power on the element will...

Page 9: ...C 10 C 3 0 Litre models 16 min 17 min 5 0 Litre models 16 min 17 min 7 5 Litre models 23 min 24 min Step 8 Commissioning Calibration Touch Start and allow 5 litres of water to flow through the filter...

Page 10: ...indicator is shown Warning The unit is now capable of dispensing boiling water without the safety feature Dispensing Boiling water Zenith Hydroboil is fitted with a safety two way cool touch safety ta...

Page 11: ...sabled item Selected Unselected item Sleep Mode Sleep When Sleep if no water used time shown Sleep when dark after 10s of darkness Sleep at time shown Sleep disabled no sleep trigger Wake When Wake wh...

Page 12: ...er Unlocked can dispense water This is the red lock button on the right side of the tap see page 10 Operating Procedure Energy Usage Energy used today kWh d The amount of energy used for the given day...

Page 13: ...choose Sleep Trigger as Timer to use this option see section 2 3 1 2 2 SETTINGS TEMPERATURE The water temperature can be adjusted as desired The default value is 98 0 C A higher value will consume mo...

Page 14: ...conveniently adjusted in groups Everyday Weekdays and Weekends After adjusting a group an individual day can be adjusted or checked by choosing the Individual days option Everyday Set all 7 days simu...

Page 15: ...e vent outlet at 0 5L min Touch Stop when complete Touch Next after flushing As prompted return the filter valve to the Filtered position Fig 3 on page 8 and then touch Done Touch Done after flushing...

Page 16: ...alibration The unit will heat the water during calibration This may take several minutes depending on the water temperature When it completes the install menu will be shown 3 3 INSTALL FILTER FLUSH Th...

Page 17: ...master code is 7395 There is a high security option in the service menu that allows the master code to be disabled Contact Zenith to enable this feature Menu Operation 6 PIN PROTECTION Zenith Hydrobo...

Page 18: ...e Dimensions 25 40 70 329 1 5L 414 3L 448 5L 561 7 5L 37 55 56 76 273 1 5L 3L 302 5L 7 5L 310 1 5L 395 3L 429 5L 542 7 5L 37 1 5L 235 1 5L 37 3L 235 3L 52 5L 250 5L 52 7 5L 250 7 5L Cold Inlet Vent Ex...

Page 19: ...tedly tripping without excessive steam Requires boiling calibration Incorrect filter flush valve setting Incorrect filter insertion Internal adjustment Perform boiling calibration see section 3 2 Chec...

Page 20: ...hs or earlier if you notice a persistent reduction in water pressure from the appliance or an unpleasant taste or odour in the water To Replace Filter Turn the filter anti clockwise Fig 1 and pull the...

Page 21: ...et 16 94456NZ Cistern Gasket 17 94509NZ Cistern Lid HB 18 93118NZ Elbow Stem 1 4 19 90100NZ Grommet Cistern to Tank 20 94458NZ Overload Item Kit Number Description 21 94459NZ Side release plug 22 9446...

Page 22: ...Page 22 of 24 804546NZ BW_HB Small_09 18 v1 02 Exploded View Diagram...

Page 23: ...n 92 c during the calibration process Check your height above sea level Call Zenith Service 7 Over temp error A constant temperature over 103 C has been reached during the calibration process Make sur...

Page 24: ...not be true representations of the finished goods The standard cup referred to in this publication is 167 ml 6 fl oz The standard glass is 200 ml 7 fl oz The terms Zenith Hydroboil Autoboil Econoboil...