d)  Outlet drainage to a sink draining board or to a drip tray.
e)  Access to drainage from a vent situated at the base of the heater.
f)  In all installation instances the walls of the heater must be vertical and 

the base horizontal, there can be no exceptions to this rule.

Before You Begin

Refer to the mounting-hole template on page 17.
Read the installation and operating instructions completely.
Decide whether to install with concealed or exposed plumbing and/or 

electrical connections. Concealed connections are preferred for superior 

appearance.

Step 1 – Positioning

Position the heater so the tap will drain on to a draining board or drip tray.
Position the base of the tap to be not less than 215 mm above the 

draining board (height should be increased only if essential for filling 

larger vessels).
Provide clearance for service access of not less than 100 mm top, 150 

mm left, 20 mm right.
Mark corner positions for the heater on the wall so as to position the 

paper mounting-hole template. 

Step 2 – Fastening

Position mounting-hole template on wall and drill holes where shown.
Drill holes for water inlet, vent outlet and wiring if rear access is intended.
Remove cover fastening screws from heater and lift whole cover off heater.
Remove filter guide as shown in picture at right. 
Install plumbing and wiring Prepare pipe ends and wiring ends as shown.
Screw heater chassis to the wall using screws or bolts suited to the wall.

Installation Procedures

COLD 

INLET

VENT 

OUTLET

INLET 

POSITION

VENT 

POSITION

Approximate Weight When Filled

3.0 Litre models

12.5 kg

5.0 Litre models

16.5 kg

7.5 Litre models

20.5 kg

100 mm

minimum 

clearance

20 mm 

minimum

clearance

from right 

edge to wall

215 mm

150 mm

Spout detail

Installation Requirements

Summary of Contents for Hydroboil Series

Page 1: ...boil 3 Litre White 303661 Zenith Hydroboil 3 Litre Stainless Steel 305662 Zenith Hydroboil 5 Litre White 305661 Zenith Hydroboil 5 Litre Stainless Steel 307662 Zenith Hydroboil 7 5 Litre White 307661...

Page 2: ...by persons including children with reduced physical sen sory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the ap...

Page 3: ...rosive or abrasive cleaners to clean the case of the heater Frost protection If this heater is located where ambient air temperature could fall below 5 C when the heater is not in use do not turn off...

Page 4: ...increased only if essential for filling larger vessels Provide clearance for service access of not less than 100 mm top 150 mm left 20 mm right Mark corner positions for the heater on the wall so as t...

Page 5: ...ter pressure requirements Minimum 150 kPa maximum 700 kPa A 500 kPa pressure limiting valve is part of the Hydroboil water inlet assembly 3 2 Venting A vent at the base of the heater must be plumbed t...

Page 6: ...ect the Live Active and Neutral wires of the concealed power cable through the rear access opening to the green terminal block on the PCB Crimp a 6 3 mm QC female spade connector to the earth wire of...

Page 7: ...se through 90 until fully engaged 20mm Step 6 Installing Filter Installation Procedures Fit the case wrapper to unit as shown in the picture below Note make sure the filter guide has already been inst...

Page 8: ...red safety lock button on the right hand side of the unit while pulling the tap lever backwards to latch it open see Fig 2 and next section for operating procedure Turn the power on the element will...

Page 9: ...C 10 C 3 0 Litre models 16 min 17 min 5 0 Litre models 16 min 17 min 7 5 Litre models 23 min 24 min Step 8 Commissioning Calibration Touch Start and allow 5 litres of water to flow through the filter...

Page 10: ...indicator is shown Warning The unit is now capable of dispensing boiling water without the safety feature Dispensing Boiling water Zenith Hydroboil is fitted with a safety two way cool touch safety ta...

Page 11: ...sabled item Selected Unselected item Sleep Mode Sleep When Sleep if no water used time shown Sleep when dark after 10s of darkness Sleep at time shown Sleep disabled no sleep trigger Wake When Wake wh...

Page 12: ...er Unlocked can dispense water This is the red lock button on the right side of the tap see page 10 Operating Procedure Energy Usage Energy used today kWh d The amount of energy used for the given day...

Page 13: ...choose Sleep Trigger as Timer to use this option see section 2 3 1 2 2 SETTINGS TEMPERATURE The water temperature can be adjusted as desired The default value is 98 0 C A higher value will consume mo...

Page 14: ...conveniently adjusted in groups Everyday Weekdays and Weekends After adjusting a group an individual day can be adjusted or checked by choosing the Individual days option Everyday Set all 7 days simu...

Page 15: ...e vent outlet at 0 5L min Touch Stop when complete Touch Next after flushing As prompted return the filter valve to the Filtered position Fig 3 on page 8 and then touch Done Touch Done after flushing...

Page 16: ...alibration The unit will heat the water during calibration This may take several minutes depending on the water temperature When it completes the install menu will be shown 3 3 INSTALL FILTER FLUSH Th...

Page 17: ...master code is 7395 There is a high security option in the service menu that allows the master code to be disabled Contact Zenith to enable this feature Menu Operation 6 PIN PROTECTION Zenith Hydrobo...

Page 18: ...e Dimensions 25 40 70 329 1 5L 414 3L 448 5L 561 7 5L 37 55 56 76 273 1 5L 3L 302 5L 7 5L 310 1 5L 395 3L 429 5L 542 7 5L 37 1 5L 235 1 5L 37 3L 235 3L 52 5L 250 5L 52 7 5L 250 7 5L Cold Inlet Vent Ex...

Page 19: ...tedly tripping without excessive steam Requires boiling calibration Incorrect filter flush valve setting Incorrect filter insertion Internal adjustment Perform boiling calibration see section 3 2 Chec...

Page 20: ...hs or earlier if you notice a persistent reduction in water pressure from the appliance or an unpleasant taste or odour in the water To Replace Filter Turn the filter anti clockwise Fig 1 and pull the...

Page 21: ...et 16 94456NZ Cistern Gasket 17 94509NZ Cistern Lid HB 18 93118NZ Elbow Stem 1 4 19 90100NZ Grommet Cistern to Tank 20 94458NZ Overload Item Kit Number Description 21 94459NZ Side release plug 22 9446...

Page 22: ...Page 22 of 24 804546NZ BW_HB Small_09 18 v1 02 Exploded View Diagram...

Page 23: ...n 92 c during the calibration process Check your height above sea level Call Zenith Service 7 Over temp error A constant temperature over 103 C has been reached during the calibration process Make sur...

Page 24: ...not be true representations of the finished goods The standard cup referred to in this publication is 167 ml 6 fl oz The standard glass is 200 ml 7 fl oz The terms Zenith Hydroboil Autoboil Econoboil...

Reviews: