SPA-V2 Public Address & General Alarm System
Installation & Configuration Manual
A100K10370
2.8.4
Jumper Settings on 4-Way Entertainment 6 Zones
Board (990-363)
Entertainment output selection
Set jumpers J1 to J6 to
ON
for Entertainment audio selection for any of
the 6 zones. This setting will be overridden by any messages or alarms.
2.8.5
Jumper Settings on SPA Multi 4-Way Entertainment
6 Zones Board (990-338)
Entertainment / Public address output selection Zone 1-6A (X131)
Select the entertainment zone(s) 1-6A by DIPSWITCH (X131) to
position ON).
Disconnect ENT zone(s) by DIPSWITCH to position ENT
Select the PA zone(s) 1-6A by DIPSWITCH to position ON).
Disconnect ENT zone(s) by DIPSWITCH to position PA
Entertainment / Public address output selection Zone 1-6B (X132)
Select the entertainment zone(s) 1-6A by DIPSWITCH to position ON).
Disconnect ENT zone(s) by DIPSWITCH to position ENT
Select the PA zone(s) 1-6A by DIPSWITCH to position ON).
Disconnect ENT zone(s) by DIPSWITCH to position PA
Entertainment / Public address output selection Zone 1-6C(X133)
Select the entertainment zone(s) 1-6A by DIPSWITCH to position ON).
Disconnect ENT zone(s) by DIPSWITCH to position ENT
Select the PA zone(s) 1-6A by DIPSWITCH to position ON).
Disconnect ENT zone(s) by DIPSWITCH to position PA
N
N
PRIO.1
N
N
PRIO.2
N
N
PRIO.3
PRIO.4
J
21
J
22
J
23
J
28
J
6
J
7
J
8
J
26
ENT. VOL
N
N
ENT. OUT
TALK BACK
ZONE ALL - TB ON/OFF
EMS+ALL - EMS ONLY
J
2
J
3
J
4
J
5
INT./EXT. 24V OVERRIDE
INT. - EXT.
N / EMS