IP addresses on a Flowire device can be set either by setting a static IP address or having one 

assigned from a temporary DHCP server. The Flowire device has, by default, DHCP enabled on one 

of their networking interfaces. The DHCP can be disabled as described in section “B.2 Disabling 

DHCP”.

B.1  Setting a Static IP Address

By default, all Flowire devices have 

169.254.1.10

 as a static IP address. 

In order to set a new static IP address:

1.  Isolate the Flowire device by disconnecting the line to other devices.

2.  Access the web interface of the Flowire device via the default address 169.254.1.10. 
3.  Enter the new IP address in CIDR notation, e.g. 10.5.202.80/24 in the 

Flowire static IP

 field

4.  Click 

Set static IP

The device will now reboot with the new static IP address.

Summary of Contents for Vingtor Stentofon FCDC1

Page 1: ...Configuration Manual Flowire Converter FCDC1 FCDC2 A100K11422 TECHNICAL MANUAL...

Page 2: ...el Ex EAPFX 1 1023221511 Exigo Access Panel Ex EAPFX 6 1023221516 Publication Log Ver Date Author Status Comments 1 5 7 2013 HL HKL Published 2 1 13 4 2016 HKL Published FCDC1 restrictions 3 2 5 2017...

Page 3: ...2 Cables Bandwidth 14 5 3 Collecting Trace Logs 14 A Power Consumption Distances for Typical Cables 16 B Advanced Configuration 17 B 1 Setting a Static IP Address 17 B 2 Disabling DHCP 18 B 3 Network...

Page 4: ...2 3 4 5 Password Reset Button 4 Ethernet Port 5 Figure 1 FCDC1 Flowire Converter There are two models of the Flowire Converter Model Description FCDC1 24 48 VDC Flowire Converter with power forwardin...

Page 5: ...digital telephone systems The above solutions typically use a conventional star wired telecom infrastructure with 0 5 mm2 20 AWG single pair twisted cables 1 2 2 Remote IP Intercom Locations In New Bu...

Page 6: ...e 3 Conventional star wired infrastructure In this solution you will have a centralized equipment rack with the following equipment Telecom Intercom Exchange Power Supply Unit Main Distribution Frame...

Page 7: ...junction boxes and grounded in the central device only Never use a cable run where the voltage drops below half of the PSU voltage Do not connect more than 10 Flowire Converters on one Flowire star co...

Page 8: ...ulti pair cables for one Flowire star configuration has to be gathered in the central FCDC2 This can be done directly in the FCDC2 if the plug has room for it on connector rails or by some other means...

Page 9: ...L DO NOT use FCDC1 to connect to local power for intercoms at remote locations L L Maximum number of Flowire devices per star configuration 10 L L DO NOT use Gigabit switch with FCDC1 as this will dam...

Page 10: ...require its own FCDC1 Flowire Converter To support the Flowire interface the central equipment rack must be equipped with an FCDC2 Flowire Converter Figure 8 Cabling in Ex Industrial Zones L L Ex dev...

Page 11: ...thernet ports If the station has a 24V input the current can be reduced to 24 volts by separating the spare pairs from the CAT cable and connecting it to this input L L DO NOT power the Flowire Conver...

Page 12: ...perature of maximum 55 C Make sure that there is sufficient space for cables and maintenance When using more than one Flowire Converter try to mount them as far apart as possible Figure 9 Flowire Conv...

Page 13: ...power a Vingtor Stentofon IP Intercom Station through its Ethernet port we recommend at least 40V at the remote site For land based installations use XP power PSU for FCDC1 Flowire XP 120 XP Power Sup...

Page 14: ...Converters however will get better bandwidth when more wires are connected between them Avoid unnecessary splicing A continuous cable will carry the signal further Regarding EMI twisted shielded cabl...

Page 15: ...15 Flowire Converter Configuration Manual A100K11422...

Page 16: ...uctor thickness described as diameter and AWG Cable Type Resistance Intercom Intercom Power Consumption 40V 0 5 mm2 20 AWG 37 8 Ohm km Turbine Compact Normal 10W 420m 0 5 mm2 20 AWG 37 8 Ohm km Turbin...

Page 17: ...d as described in section B 2 Disabling DHCP B 1 Setting a Static IP Address By default all Flowire devices have 169 254 1 10 as a static IP address In order to set a new static IP address 1 Isolate t...

Page 18: ...urn off the DHCP client on the device this can be done via the device web interface To disable DHCP Click Toggle DHCP DHCP will be disabled or enabled depending on the previous state The DHCP enabled...

Page 19: ...n To set a new NMK password 1 Log into the Flowire device by entering its IP address e g 10 5 202 80 in a web browser 2 Click the Upgrade form button 3 Enter a new password in the Flowire NMK field 4...

Page 20: ...an IGMP querier do not enable IGMP querier in any of the Flowire units 2 1 2 IGMPv2 Compatability Current versions of Cisco industrial switches only handle IGMPv2 Therefore the Cisco switch should be...

Page 21: ...o optimize availability it is recommended to always configure the FCDC2 in the rack to be CCo Due to its location it is least likely to suffer damage If this Flowire unit fails the star configuration...

Page 22: ...rsion 4 x installed from factory and can be upgraded via the web interface or via the VS IMT tool Hardware version 0104 Item no 1008080110 0104 and older has version 1 x or 2 x installed from factory...

Page 23: ...al A100K11422 After the Flowire devices have been discovered Select all Flowire devices Click NEXT twice skipping STEP 2 Identify stations Make sure the correct Flowire software is selected CTRL Click...

Page 24: ...nfiguration Manual Click the Upgrade button to start the process The upgrade process should take about 1 minute per Flowire device When the upgrade progress bar is at 100 Click NEXT twice Click FINISH...

Page 25: ...etup Start the Tftpd program on the PC In the TFTP server Browse to the directory where the Flowire software is stored Make sure that the correct Server interface is selected C 2 2 Flowire Device Web...

Page 26: ...ts to factory setting L L For Full upgrade resetting the device to factory default setting also implies changing the NMK password to its factory default By doing so all communication with the connecte...

Page 27: ...part or in whole must include this legend Zenitel All rights reserved customer service zenitel com DOC NO A100K11422 The WEEE Directive does not legislate that Zenitel as a producer shall collect end...

Reviews: